• Vegetable Cutter Used  for  Hotel School Company System 1
  • Vegetable Cutter Used  for  Hotel School Company System 2
  • Vegetable Cutter Used  for  Hotel School Company System 3
  • Vegetable Cutter Used  for  Hotel School Company System 4
  • Vegetable Cutter Used  for  Hotel School Company System 5
Vegetable Cutter Used  for  Hotel School Company

Vegetable Cutter Used for Hotel School Company

Ref Price:
get latest price
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Vegetable Cutter discription:

Multifunction vegetable cutting machine, cleaning machine for fruits and vegetables, frozen meat dicing machine, shredded meat, sliced meat machine corm shredding machine, ginger shoot silk machine, cut machine, cutting machine and ducks row

Q: Know flow and lift how to calculate the pump power?
P: the density of refrigerant, when the working fluid is water, P =1ETA - pump efficiency, can not find desirable value =0.8N=30x (200/3600) x9.81x1/0.8=20.44 = 20 (kW)(that is, 20kW motors)
Q: What is the Rhodes pump?
Best answerRoots vacuum pump (referred to as: Roots pump) refers to the pump is equipped with two opposite direction of synchronous rotation of the leaf rotor, rotor, rotor and pump housing between the walls of a small gap and no contact with a variable capacity vacuum pump.Roots vacuum pumps have been tested for long time in the fields of petroleum, chemical, plastic, pesticide, steam turbine rotor dynamic balance and aerospace simulation, so it should be popularized and applied in china. It is also widely used in petroleum, chemical, metallurgical, textile and other industries. Vacuum pump fittings are used for noise control of vacuum pumps, vacuum pump silencers.
Q: What is the "variable" of a variable pump? Is the displacement change or the flow change? Thank you
There are many ways to change the variable pump flow: by changing the eccentricity to change the piston stroke length (radial piston pump, the frequency change principle) motor speed to adjust the flow (such as gear pump flow control principle).
Q: What's the difference between non negative pressure and variable frequency water pump?
When peak water is used, the fluctuation of water pressure will be the same for customers! Because the key to the fluctuation of hydraulic pressure is the flow rate of the pump and the lift of the pump. As long as the flow of the selected pump is large enough, the tank is large enough, the lift head is suitable, and the pressure fluctuation is relatively small. And the selection of non negative pressure and frequency conversion pump group is not directly related. If the municipal tap water pressure and water sufficient (large enough diameter), the use of non negative pressure is better. If the municipal tap water pressure and water shortage, you can only use the frequency converter pump + water tank, no negative pressure can not be used.
Q: Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
Select the hydraulic pump from the following considerations:1. hydraulic pump pressureHydraulic pump operating pressure is the pump (or motor) in actual work output (or input) oil pressure, determined by the external load.Rated pressure refers to the maximum pressure under continuous running in accordance with the test standards under normal working conditions. The size of the pump is limited by the service life, and the service life of the pump (or motor) will be shorter than the design life if it exceeds the rated pressure. When the work pressure is greater than the rated pressure, it is called overload.
Q: Why does the centrifugal pump start and close first when the outlet valve is closed?
The operation rules of centrifugal pump strictly required to close the outlet valve before the shutdown, boot and then slowly open the outlet valve, regulating pipeline pressure and current range. The reason is: the centrifugal pump in the startup process in order to avoid large starting current caused by electrical faults, such as circuit breaker tripping,
Q: What is an industrial water pump?
Classification by usagePump, circulating pump, fire pump, pressure test pump, sewage pump, metering pump, sanitary pump, dosing pump, pump, pump, gelatinization defoaming pump, flow pump, oil pump, water pump, drainage pump, drainage pump, dredging pump, sprinkler pump, booster pump, high pressure pump, heat pump high temperature, low temperature, pump pump, condensate pump, heat pump, cooling pump, heating pump, deep well pump, analgesic pump, pump, pump, chemotherapy, blood pump material pumping pump, pump, pump, sulfur removal, shearing grinding pump fuel pump, pump, pump, quillback bath source heat pump, filter pump oxygen pump, pump, shampoo, injection pump, air pump, gas pump, pump, pump, art odorization pump chopped
Q: Types and differences of pumps
(I) volumetric typeClassification reciprocating rotary typeThe basic principle of reciprocating action by the piston in the cylinder in the cylinder volume changes again, with the suction and discharge of fluid in the shell or the rotor rotating member rotates, the volume of work between rotor and casing changes to the suction and discharge fluid, such as piston pump gear pump, screw pump(two) blade type;The main structure of vane pumps and fans is rotary, bladed impellers and stationary housings that rotate fluid through the impeller to do work, thereby enabling fluids to obtain energy
Q: Filter backwash pump for what use, what is the principle of work ah?
Regeneration of the filter medium is required to regain the filtration capacity of the medium. The regeneration process is mainly accomplished by the backwashing pump (the backwash pump is not a special pump, referring to the pump for the completion of the process). The working principle is through the cleaning liquid from the downstream of the filter into the backwash pump (alkali, acid and water), reverse flushing filter medium, cleaning liquid discharged from the upstream, this process can be attached to the dielectric surface and internal impurities washed away.
Q: Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
The centrifugal pump at a fixed speed, the head is fixed, adjust the outlet valve to adjust the diversion area