Power

0.5kVA-10kVA(Horizontal)

5kVA-60kVA(Vertical)

Single phase input voltage

70V-130V and 160V-250V

160V-250V

Single phase output voltage

220V and 110V

220V

Accuracy of voltage stabilization

220V±3% 110±6%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Three Phase Four-wire AC Voltage Regulator

Power

1.5kVA-60kVA

Three Phase Input Voltage

Phase voltage 160V-250V;Wire viltage 277V-430V

Three Phase Output Voltage

Phase voltage 220V;Wire viltage 380V

Accuracy of voltage stabilization

2-5%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Power

0.5kVA-10kVA(Horizontal)

5kVA-60kVA(Vertical)

Single phase input voltage

70V-130V and 160V-250V

160V-250V

Single phase output voltage

220V and 110V

220V

Accuracy of voltage stabilization

220V±3% 110±6%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Three Phase Four-wire AC Voltage Regulator

Power

1.5kVA-60kVA

Three Phase Input Voltage

Phase voltage 160V-250V;Wire viltage 277V-430V

Three Phase Output Voltage

Phase voltage 220V;Wire viltage 380V

Accuracy of voltage stabilization

2-5%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Application

 

Widely used in the fields of post office,store,elevator,hospital,school,publishing house and stock exchange where normal voltage is in need,and also can be used in the factories of large and middle-scale industrial and mining corp,it is very much suitable for some important devices and supporting single machine.

 

Input voltage

Three-phase four-line system phase voltage:220±20%

 

line voltage:380±20%,or phase voltage:220±30%

line voltage:380±30%(can be selected.Please specify when ordering)

Single-phase:220±20% or 220±30%(can be selected.Please specify when ordering.)

 

Output voltage

Phase voltage:220V Single-phase:220V Line voltage:380V

Output voltage accuracy

1-5%(can be adjusted)Frequency:50HZ/60HZ

Efficiency

≥98%(Power grade over 50KVA)

Ambient temperature

-10~+40°C

Insulation resistance

≥5MΩ

Electric intensity

The voltage for electrical strength and power frequency sinusoidal is 2000V without breakdown and flash over when lasts 1minute

Overload Capacity

It can last 1 minute at the rated current of two times

Wave form Distortion

No additional waveform distortion

Protective function

it offers the protections against over voltage,over current,phase shortage and phase-sequence(The single-phase offers no protection against the phase shortage and phase-sequence)and mechanical failure

Response speed

≤1s(in the condition that the external voltage changes is 10%)

 

 

Q: What transformer can be used in a safety voltage lighting transformer?
An isolated transformer is a transformer that is electrically isolated from an input winding and an output winding. The isolated transformer is used to avoid accidental touching of the charged body at the same time, and the isolation of the transformer is to isolate the current of the former side winding coil.
Q: How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
Voltage x current = power, in general we are using the total power of 2/3, you can press this type of calculation, if the installation of electrodeless lights, the line should be separated,
Q: Who knows how big transformers and lines the 36V transformer uses in lighting?
No matter how many volts the output / input voltage of the transformer is, the size and the amount of the core of the transformer, the wire diameter of the winding lead and the lead thickness must be determined by the transformer capacity. Example: input 220V, output 36V load is 36v/40w light bulb 6, so the primary needs 0.72, secondary use 1.81 diameter enameled wire winding system. The transformer capacity is about 250VA.
Q: What type of low voltage transformer should be adopted for safety lighting power supply?
We have produced many low voltage lighting transformers, such as outdoor waterproof, high-power stage lighting, as well as indoor small power transformers, customer response, but also good! For example, Guangzhou Color Art Lighting Co., Ltd., before them, our reputation is good!
Q: How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
General digital multimeter has a capacitor (some of the files with a million capacitance test table of Jack, some use pen)
Q: Is the substation separate from the power and illumination transformer?
There is only bus in the substation, and the station is connected with the transformer from the bus. If there is no electricity even in the bus, then the substation should not be considered active.
Q: The transformer zero line has broken, has the result to the household illumination circuit?
The power supply system in three-phase four line zero line is broken, the breakpoint of the single-phase circuit (220V) electrical burn by voltage to 380V. I met, the incandescent lamp suddenly particularly bright then the blow up of internal fuse TV has burned out. So in the three-phase four wire power supply system zero line asked to do repeat grounding in households is the reason.
Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
What you think? Your light is 220V, right. Over 36V, it's better not to live with electricity unless there is good protection
Q: Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
If the transformer is not calculated, the loss is the same. If the calculation is the latter, save electricity.
Q: Why can't autotransformer be used as transformer for safety lighting?
The main and auxiliary coils of the autotransformer have common parts. Once the short-circuit is made, the lighting circuit is directly connected with the high voltage circuit, which is very dangerous
We have set up stable trading cooperation with customers from the Middle East, South Africa, North America, Europe and other areas worldwide. We gain a good reputation among customers and lay solid foundation for our development. And we believe that we can be your faithful friends and reliable partner forever.

1. Manufacturer Overview

Location Shanghai, China
Year Established 2008
Annual Output Value US$50 Million - US$100 Million
Main Markets South America
Eastern Europe
Southeast Asia
Africa
Oceania
Mid East
Eastern Asia
Western Europe
Central America
Northern Europe
Southern Europe
South Asia
Domestic Market
Company Certifications CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Shanghai Port,Ningbo Port,Guangzhou Port
Export Percentage 81% - 90%
No.of Employees in Trade Department 6-10 People
Language Spoken: English, Chinese, Spanish, Arabic, French, Russian
b) Factory Information
Factory Size: 3,000-5,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords