Outdoor UPS HW9110E Series
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 2 Pieces pc
- Supply Capability:
- 30 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Key Features
1. Providing with pure sinewave power for outdoor telecom and network equipment.
2. Be suitable for outdoor severe Temperature,Humidity and harsh Environment, especially can meet the outdoor electric network requirements. (Outdoor environment is severe and quality of electric network also is so bad . For example outdoor high temperature is 50 and severe winter is 40,Voltage range is from 160V to 260V even easily change )
3. Adopting sealed natural cold design, high-temperature resistant ,cold resistant and corrosion resistant,that degree of sealing is IP55 .
Model | HW9110E 1-10KVA | ||||
1KVA | 2KVA | 3KVA | 6KVA | 10KVA | |
1KVA/800W | 2KVA/1600W | 3KVA/2400W | 6KVA/4800W | 1000KVA/8000W | |
220/230/240VAC | |||||
50/60HZ | |||||
115~295VAC(±3VAC) | 176~297VAC(±3VAC) | ||||
50HZ(46~54HZ),60H(56HZ~64HZ) | |||||
0.98 | |||||
220/230/240X (1±2%)VAC | |||||
50/60HZ±0.05Hz | |||||
0.7/0.8(optional) | |||||
Linear load<3% Non-linear load <6% | |||||
Overload (110% ~ 150%) for 30 seconds,then automatically transfer to bypass.When load is normal,it can automatically transfer to normal mode. | |||||
3;1 | |||||
0ms(AC to DC ) | |||||
36VDC | 96VDC | 96VDC | 240VDC | 240VDC | |
4A/8A(optional) | 4A/8A(optional) | 4A/8A(optional) | 4.2A | 4.2A | |
(38/65/80/100AH)optional | |||||
Display input and output voltage, frequency, battery voltage, battery capacity, load percentage | |||||
RS232,SNMP card(optional) | |||||
0~40°C | |||||
0~95% Non-condensing | |||||
-25°C~55°C | |||||
<1500m | |||||
<50dB | |||||
85 | 125 | 125 | 150 | 155 | |
640×900×900 | 640×900×1185 | 640 ×900×1185 | 940×940×1770 | 940×940×1770 |
- Q: How many power illuminator can 5Kva 36V transformer drive?
- Transformer (Transformer) is a device that uses the principle of electromagnetic induction to change AC voltage. The main components are primary coil, secondary coil and iron core (magnetic core). The main functions are voltage conversion, current conversion, impedance transformation, isolation, voltage stabilization (magnetic saturation transformer) and so on. According to use can be divided into: power transformers and special transformers (electric furnace transformer, rectifier transformer, power frequency test transformer, voltage regulator, mine, variable audio transformers, intermediate frequency transformers, high frequency transformer, transformer, instrument transformer, the impact of electronic transformer, reactor, transformer etc.). Circuit symbols are often used as the beginning of numbers. Examples: T01, T201, T, etc..
- Q: What type of low voltage transformer should be adopted for safety lighting power supply?
- In general, indoor transformers are used in general practice
- Q: Why should lighting transformers be used in factories and mines?
- In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
- Q: Why is elevator lighting transformer installed?
- 1) a lamp shall be installed at the highest and lowest point 0.5m away from the hoistway, and a light shall be installed at intervals not exceeding 7m, and a control switch shall be installed in the engine room and the bottom pit respectively;2) the lighting power supply for car top and hoistway shall be 36V; when 220V is adopted, the residual current action protector shall be installed;3) there is no lighting device for a closed well road with sufficient lighting conditions around the hoistway.
- Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- What you think? Your light is 220V, right. Over 36V, it's better not to live with electricity unless there is good protection
- Q: How is the lighting power of the 380V transformer calculated?
- With a light bulb with 4KVA load, the premise of the distance can be Mrs. face light bulb, dark can light the best load, 3KVA bulb brightness
- Q: Can the 500 volt lighting transformer be changed into an electric welder?
- 500 VA transformer should not be used as an electric welding machine, so it is very difficult to reform the system, so it is better to buy a new electric welder
- Q: Power and lighting transformers, lighting quality will be affected much?
- Corresponding to the transformer power supply, in order to save costs and reduce costs, the choice of AC ignition method is better. Pure resistive load, the power factor is 1. The 3 *100W=300W is the capacity of the required transformer
- Q: Lighting, lights, transformers, bulb brightness is too low, what's the matter?
- Line light for safety light, voltage 24 volts and 36 volts, pay attention to the bulb and transformer voltage matching.
- Q: How to calculate the rated capacity of small transformers for lighting purposes?
- Capacity of power transformer is the basic equipment for a total capacity of [kW] (maximum power consumption rate by a / X100 capacity) divided by the power load [%] value for benchmarking.
1. Manufacturer Overview
Location | Guangdong,China (Mainland) |
Year Established | 2006 |
Annual Output Value | US$10 Million - US$50 Million |
Main Markets | 9.09% North America 9.09% South America 9.09% Eastern Europe 9.09% Southeast Asia 9.09% Africa 9.09% Mid East 9.09% Eastern Asia 9.09% Western Europe 9.09% Southern Europe 9.09% South Asia |
Company Certifications | UPS CE UG/UX 1K; UPS CE (UG/UX) 2/3K; standards organisation of nigeria soncap; Soncap UX6K |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shenzhen China |
Export Percentage | 61% - 70% |
No.of Employees in Trade Department | 11-20 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | 10,000-30,000 square meters |
No. of Production Lines | 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
Outdoor UPS HW9110E Series
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 2 Pieces pc
- Supply Capability:
- 30 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches