Mineral Wool Insulation for Roofing and Thermal Insulation

Mineral Wool Insulation for Roofing and Thermal Insulation

Ref Price:
$5.00 - 10.00 / m² get latest price
Loading Port:
Tianjin
Payment Terms:
TT or LC
Min Order Qty:
10000 m²
Supply Capability:
1000000000 m²/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Mineral Wool Insulation for Roofing and Thermal Insulation

1.Structure of Mineral Wool Insulation for Roofing and Thermal Insulation

Rock wool insulation refers to a type of insulation that is made from actual rocks and minerals. It also goes by the names of stone wool insulation, mineral wool insulation, or slag wool insulation. A wide range of products can be made from rock wool, due to its excellent ability to block sound and heat. This type of insulation is commonly used in building construction, industrial plants, and in automotive applications.

 

The Manufacturing Process

Melting / Forming into fibers /Continuous-filament process/Staple-fiber process/ Chopped fiber/ Rock wool / Protective coatings /Forming into shapes

2.Main Features of Mineral Wool Insulation for Roofing and Thermal Insulation

● FEATURES

Thermal Insulation

Fire Safety

Acoustic Control

No Corrosion

Environmental friendly

Moisture Resistance

Energy Conservation & Emissions Reduction

Different raw material: Our rock wool is mainly made by Basalt and other natural ores. The raw material for other so-called rock wool is mineral slag. Different raw material, different features.

Different corrosion resistance. Our rock wool have good corrosion resistance. non-corrosive for metal. But the mineral slag wool is different. In high humidity environment, CaS in mineral slag will have chemical reactions and produce corrosive when contact with metal.

Different working life. The working life for mineral slag is very short and Durability is very low because of higher CaO and MgO in slag. The efflorescence for mineral Slag is easy and also effect the working life. The

Different heat resisting. The heat resisting for rock wool(Basalt) is higher than mineral Slag wool. Our operating temperature can reach 800.But for Slag wool ,can not higher than 675.The features for our rock wool is totally superior to Slag wool.

3. Mineral Wool Insulation for Roofing and Thermal Insulation Images

 

 

4. Mineral Wool Insulation for Roofing and Thermal Insulation Specification

ROCK WOOL BLANKET & BOARD

Standard Size

Product Blanket Board

Density (kg/m3) 60-100 40-200

Size: L x W (mm) 1200X3000-6000 600X1200

Thickness (mm) 30-150 30-100

Remark:

Other sizes are available upon request.

Facing materials can be applied upon request.

 

Standard Size

Product Blanket Board

Density (kg/m3) 60-100 40-200

Size: L x W (mm) 1200X3000-6000 600X1200

Thickness (mm) 30-150 30-100

Remark:

Other sizes are available upon request.

Facing materials can be applied upon request.

Rock wool PIPE

Standard Size

DIA Thickness (mm)

inch mm 25 30 40 50 60 70 80 90 100 120 150

1/2’’ 22

3/4’’ 27

1’’ 34

1-1/4’’ 43

1-1/2’’ 48

2’’ 60

2-1/2’’ 76

3’’ 89

3-1/2’’ 108

4’’ 114

5’’ 140

6’’ 169

8’’ 219

10’’ 273

12’’ 325

14’’ 356

15’’ 381

16’’ 406

18’’ 456

19’’ 483

20’’ 508

22’’ 558

24’’ 610

 5.FAQ

We have organized several common questions for our clientsmay help you sincerely

①     What’s the mainly material for rock wool

Rock wool is called a mineral wool because it is made primarily from basalt, an igneous rock,

What’s the mainly type for rock wool

rock wool insulating products are available in loose-fill form and as batting. Batts, or blankets, are thick slabs of insulation that may have a kraft paper facing.

How you control the quality?

During the production of fiberglass insulation, material is sampled at a number of locations in the process to maintain quality.

 

Q:The distance between knee wall and attic ceiling is about 6 foot. Could I push a perforated pipe between the rafters?
That is an option. And there aren't many options.Not much is going to slide easily behind the insulation. I'm thinking --------------------. You are undoubtedly going to snag on roof nails coming through the decking. I don't know if they would hold up but the cardboard tubes wrapping paper comes on might work if you tape 2 together. and flatten and tape the end you will be pushing in first. cut slots with utility knife. I think your idea would work if you can afford the pipe. That's a tough one. When we convert attics we line those cavities with a styrofoam insulation chute end to end until we reach open ventilation-you probably know that by now. Give it a try.
Q:So I'm renovating an old farmhouse with a metal roof and there is no insulation in the attic. I was up in the attic checking for leaks since we just got some freezing rain and it is currently melting I thought now was the perfect time to check. I found no leaks but I did notice the roof was sweating with noticeable beads of water in many places and many of the 2x4's that act as the frame were damp, although none were rotted (I found that odd as the house is approx. 140 years old and those are the original 2x4's. I could tell that the attic does have vents so I guess it dries out before rotting or mold occurs.. but makes me wonder if I put down some roll-in faced R-30 Owens Corning Insulation and then add a plywood floor over top if everything will be fine.. or not so fine..
I own an 80 year old house -- a home originally built as temporary housing for people working in the airplane industry during the war, and for returning soldiers. Temporary housing that is better structurally than many new homes. In fact, the original design and work was brilliant in its simplicity and precision, and I have found that the problems with my house are the result of work done later on -- additions and fix ups that screwed with the original integrity. One thing I have learned RE old houses is it is often best to leave well enough alone. This does not mean one should not address definite problem, or add certain features, but it does mean one has to think things through and do a great deal of research before acting. As you say, the structure of the roof is the original, so all the folks who had the house before you must have been doing something right. If I were you, I would ask around my community, do some internet searches, and find someone in your area who is an expert on dealing with historical structures of the area. This person will not necessarily be a master craftsman with a PhD in history and another in architecture. It may actually be a skilled handyman or carpenter who is continuing the old family business. He also probably lives in an old farm house, or knows plenty of folks who do. THAT is the guy you want to consult.
Q:I am specifically considering the re-roofing of a an older home where rafters were made with 2x4 or 2x6 and the rafter space (and possibly the attic space) does not allow sufficient space for insulation and proper ventilation behind the insulation. The old layers of roofing have to be removed in any event. At this point I am considering applying insulation boards on the existing sheathing and then a new layer of sheathing before the new roofing material. (similar to a SIP: structural insulated panel) The two issues I am concerned with is that the insulation can act as a vapor barrier. Would condensation potentially rot the lower sheathing. How is this avoided in SIP roofing panels? The second issue may be with fire regulations.
Good question and I do not know the answers. For the fire issue, call your local fire department and chat them up. Then call your building inspector and talk with him. If he's been around awhile he may have seen it done before and have some information on how it has worked out or what are must do's.
Q:Hi, my building is hot in temperature in summers, so I am finding ways to tackle the problem by placing some heat insulating materials against the sunlight on the roof of my building. I have found several possible solutions, but none of them close to perfect. 1. grass layer: hard to maintain2. heat-insulating brick: might be too heavy to carry them to the roof3. heat-insulating coating: would it be damaged if we step on them? Are there things like heat-insulating carpets that would be convenient to instal?
If you're redoing the roof, a radiant barrier under the sheathing helps. So does insulation. And also, if there is an attic space there, consider putting in a fan to blow the hot air out.
Q:What is the aim of insulation in walls and in roofs?
Insulation can reduce your heating cost. Insulating your solid walls could cut your heating costs considerably, because solid walls let through twice as much heat as cavity walls do.
Q:Should a two story home have insulation under the roof in the big closets ?
Hell yes it should. A lot of contractors skimp on insulation though. Every singe area in your attic under your roof needs fiberglass insulation or you will lose heat and air and your electric bill will be higher. Heat rises and u will lose it fast in the winter if there is just one small spot without it.
Q:Can you put fiberglass insulation on the under side of roof tiles in the loft in the house?
I would be concerned that this may cause moisture to form between the roofing and the insulation. They make a special foam panel that fit underneath the roofing in between the roof rafters. They allow air to flow from the eave to the roof's ridge.
Q:we have liq. ammonia storage tank (capacity 40000 ton)having double wall & suspended deck.liq. NH3 stored at temp -33 degree cent. insulation (form ) being provided to annular space (wall ) but not on top roof . can you explain for exact reason.with regardsanvar shaikh
Insulation is less necessary on the roof. The ammonia is mostly a liquid, and a liquid would absorb heat rapidly from tank walls. Above the liquid is vapor, and vapor absorb heat much less rapidly than liquid does, so insulation is less important there.
Q:... building code max. (R-50)???
The roof can also be heated enough to melt snow/ice by the sun. I wouldn't assume it's being caused by heat escaping from inside. That said, just because you have R50 doesn't mean it's perfect - it's not. Some heat will still escape. Prefect insulation is not feasible.
Q:i live in a tropical country and i need to insulate my roof to block off the heat from the sun...which insulation would best help me? aluminum foil with foam, real foil with foam or PE with foam? pls help...thank u so much!
Use HDPE foam (high density polyethylene) - possibly with a layer of aluminum foil sandwiched in between. It's also waterproof (polystyrene isn't).

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches