galvanized pipe clamp with welding nut

Ref Price:
$0.03 / pc
Loading Port:
Qingdao
Payment Terms:
TT LC
Min Order Qty:
100 pcs pc
Supply Capability:
300000pcs Per Month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Usage: Pipe Clamp
Material: steel、matel;Galvanized iron ,stainles
Band width:3mm/20mm
Connection:welding
Model number:As your requirement
Structure:Swivel clamp
Certificate:ISO9001:2008
Feature:
1.Use the open internal and external circle structure,and with screw fixed.It is effectively to solve the problem that when small diameter solft tube connect the hared tube,it is easy appear dead angle,and liquid or gas leakage problem.Easy structure,Easy maked.
2.Edge is no burrfree,it is ability to prevent the tube damaged
3.By a efficiently hydrogen relief treatment,long-term use needn't to worry fracture and other problems
Surface: zinc plated Packaging
4.Accord with DIN3017 Standard.By 48 hours salt and fog test,it has a good corrosion resistance
5.By our last 48 hours elastic test,to insure a high strength mechanical properties.
6.Easy to fix.
Working Temp: -40 ℃ ~ 110 ℃
Size:3/8" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2
Structure: Suspension Clamp and so on On-time shipment and pre-shipment product quality safeguards clamp is mainly used in automobiles,tractors, ships, gasoline engine, and so on each kind of mechanical
device for oil, gas, hydraulic hose connector, various types of
rubber tube interface must join parts fastening.
Detail: plywood case ,pallets or any other package as buyer's requirements
Delivery Detail: about 20-30days

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What kind of appliances are these? What role does it play? Not how the measured current clamp meter?
The relay is used as protective and breaking circuit, and the current parameter is usually marked on the top, and the unit is A.
Q:Method of using current clamp
Clamp meter before the measurement was estimated the size of the current, and then decide which range. If you can not estimate, you can use the maximum range file, and then appropriate to smaller, to accurate readings. Small current cannot be used to measure high current. To prevent damage to the clamp type meter.
Q:How to auto discharge clamp current meter
The clamp type meter works like a transformer.A primary coil is a traverse through a clamp core, equivalent to the primary coil of a transformer with 1 turns, which is a step-up transformer. The two coil and the ammeter used for measurement constitute the two loop. When the wire is AC current through the coil, which is the alternating magnetic field, induction current is generated in the two loop, the size of the current and a current ratio, the equivalent of a number of turns and two coil inverse. The clamp type ammeter is used for measuring high current. If the current is not large enough, the primary wire can increase the number of turns through the clamp table and divide the measured current by the number of turns.
Q:With the operation of the motor current clamp meter measuring three-phase, single-phase current is very low, what is the reason?
Is there a problem with the removal of the caliper?. If you have checked, no problem, you can determine the correct data, low current, or motor without load or light load, or the power of the motor itself is small.
Q:How to find out the broken capacitor in the three-phase capacitor of the reactive compensation cabinet with the clamp table?
Use clamp meter measuring each capacitance of each phase current, no current is failure, current ratings than too much capacity loss.In fact, do not need to use a clamp meter measurement, the reactive power compensation cabinet in manual operation, and observe the 3 input capacitance by monitoring the current cabinet said the number and capacitance rating (each) to determine whether the sum of.
Q:I would like to ask the relationship between the power of the water pump motor and the flow of water
As long as the valve is fully opened, the motor is not overloaded, so that the frequency flow can be adjusted by using a flow transmitter or a pressure transmitter with frequency conversion. As long as the setting is good, the automatic control can be realized automatically.
Q:How does three-phase motor check current?
Fu photoelectron FM 7 series high precision digital multimeter professional measuring instruments, portable, large screen LCD digital display and backlight, easy reading, single hand operation for measuring range switch, with overload protection and low battery indicator, is an ideal tool for the use of professional maintenance personnel, factories, schools and other institutions the.
Q:What's the difference between a caliper meter and an ordinary multimeter?
Clamp meter to measure the current does not need the pen, as long as the pliers to the circuit working on a "bite", reading can be displayed immediately, the convenience is self-evident. Because of its convenience, the measured current clamp meter, often measured power personnel standard.
Q:Current and power conversion of clamp type meter
Single phase 220V circuit, current, *220= power.
Q:How can the clamp meter measure alternating current?
The general type for measuring current clamp meter, you open the jaw vise current wires can be, if you want to measure the AC voltage, can use the pen, with a multimeter used almost

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing