Quick Detail:
One Hole EMT Conduit Strap
Material: Zinc Plated Steel
SIZE: 1/2”—4”
Standard: UL
Field Names:
EMT Conduit straps, EMT one hole strap, EMT conduit clip, EMT one

 

 

Q: 1000 kW 600 m cable to use much
1000kw ah that with three groups of 400-ping line should be no problem
Q: Is the cable head made of every building?
First, the cable production and installation of each building has. Second, the cable terminal set of waterproof, stress control, shielding, insulation in one, with good electrical and mechanical properties, in a variety of harsh environmental conditions for long-term use. With the advantages of light weight, easy installation and so on. Cable terminal is widely used in electric power, petrochemical, metallurgy, railway ports and construction and other fields. Third, the production process: including the following: . cut off the excess cable; . the cable protective layer of the stripping; . conductor connection; . wrapped around insulation (or shrink pipe); . install the connector shell; . ; . for sealing treatment.
Q: What is the meaning of PG + digital markings for electrical wiring?
The best cement and other dry in the closing, because the wet cement contains moisture, can be conductive, dry the probability of conduction less. Pay attention to the wire to maintain integrity, no broken skin, it is best to protect the casing.
Q: 3 by 16 cable is a few flat? How? That 5 by 16?
Motherboard and power supply problem, the best way is to try to USB2.0 ban on the use of USB1.1 but will be slower
Q: Does anyone know the "line buckle" classification (including shape / size / material / has been some commonly used size!) Line deduction is a hardware products! For daily necessities!
In accordance with the relevant safety regulations, the power cable should not be parallel to the top of the thermal pipe laying, when can not be avoided, the interval distance should not be less than 1000mm, during which should also take effective insulation measures. Power cable and thermal pipe cross, the thermal pipe insulation layer, the separation distance should be not less than 500mm, no insulation layer should not be less than 1000mm, and in the cross with the insulation board to be protected, the length of the insulation board should not be less than d + 2000mm (d for the thermal pipe insulation layer diameter).
Q: 5 air conditioning can be used 4 square cable
You do not use the 9V power supply, a long time will burn the router.You'd better measure the original adapter voltage, if you want to extend the power cord, it is best to use a thick line of reliable connection, you can not start now, you can not start Depending on whether the extension line is too thin, causing the voltage drop too much.It is necessary to extend the front end of the adapter can extend the 220V power cord.
Q: The difference between nylon balls and geese and ducks
It depends on the thickness of the wires you use. The thicker the copper wire is, the better. Because the distance will be a voltage drop. So be it, you use a multimeter to look at how long you charge when the output voltage is how much. If you can more than 50 should be no problem. If the voltage is relatively low can change a rough wire, or find a few wires in parallel can also be. I do not know if you can understand it. Even if there is a voltage drop if it is not very powerful should not be the problem, the worst result is the battery charge dissatisfaction. You can try to see how the effect of the day. Certainly will not break your equipment and battery, rest assured it
Q: How do I ask for cable prices? How many tons is one or more?
Cable bridge grounding should belong to the protective grounding, grounding resistance at a cross point is not greater than 50 milliohms, no jumper no more than 5 milliohms
Q: 6 square cable up to how many air conditioning (1.5P)
1 square millimeters can flow 4A current, 1KW380V, then the current is about P = UI about 2.6A7KW, 380V, then the current is about 18A, each with the line to share 18/3 = 6A2.5 square mm of copper on it. Of the area need to take . probably 6 level. V is probably 7KW220VI = p / u = 7000/220 = 31A. Then need 10 square millimeters of copper.
Q: 25 square copper cable how much money one meter?
3 plus 1 64.13 yuan, 3 plus 2 75 yuan, 4 plus 1 81.38 yuan contact to see my registration name