Ductile Iron wafer butterfly valves DN340

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 set
Supply Capability:
80000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Size:

DN50-DN1000

End flange:

ANSI B 16.1,EN1092,AS2129

Face to face:

ANSI B 16.10

Top flange:

ISO 5211

Normal pressure:

PN1.0/1.6MPa(150/200PSI)

Body:

CI/DI/WCB/ALB/CF8/CF8M

Disc:

DI/ALB/Rubber lined Disc/1.2501/1.4529/CF8/Hastelloy Alloy/Monel

Stem:

410/416/304/431/17-4PH/316/monel

Seat:

NBR/Hypalon/EPDM/Neoprene/NR/Wear-Resistant EPDM/Viton/Silicon/Heat-Resistant EPDM/White EPDM/EPDM(NSF)/PTFE

Suitable temperature:

-10~120

Medium:

Fresh water, sewage, sea water, air, vapor, food, medicine, oils, alkalis, salt etc. 

 

A butterfly valve consists of body ,stem ,disc , actuator (manual actuator, worm-gear actuator , aerodynamic actuator or electric actuator) , and wafer type butterfly valve can implement the process for turning on turning off and regulating the flow by the circumrotation of stem and disc  that is droved by actuators.
 

1.Simple and compact construction. Small in size and light in weight. Easy transportation, installation and maintenance.
2. Quick 90 degrees on-off operation. Minimized operating torque ,energy saving.
3. Excellent sealing performance with no leakage. Long service life.
4. Wide selection of materials ,applicable for various media..
5. Flow curve tending to straight line. Excellent regulation performance.

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Is the pressure test of the centerline butterfly valve checked or checked?
Every factory factory must require pressure tests.
Q:anti siphon valve?
anti siphon valves are junk. just install regular valves and put in a backflow preventer on your mainline before all the valves, but right after the shut off vavles.
Q:Does the pneumatic butterfly valve need electricity?
Yes, for emergency power off, use the 24V power belt with pneumatic butterfly coil to allow pneumatic valve to work
Q:Read your answer, about pneumatic butterfly valve solenoid valve selection
DN200 pick 1/4DN350, DN400 corresponding solenoid valve, you can choose 3/8 hose 12mmOther accessories are related to valve path and pressure. If the same series, the valve has no change at all.
Q:CAD drawing of butterfly valve
Your question is very international. Ha-haThis method of painting is not clear in one or two words.First you'll know the map, then you'll use CAD, so the two will add up.Guess you will.
Q:What's the difference between an electric two position control valve and an electric butterfly valve?
Double switch electric butterfly valve, electric butterfly valve is usually said, namely the electric butterfly valve in the electronic case can achieve fully open or fully closed precise place to stop, not directly with the pipeline system flow feedback device for regulating the flow of accurate interaction.
Q:can't locate freon intake valve for 03 jaguar?
There is no Freon intake valve for an 03 Jaguar. Freon is R12 refrigerant and the vehicle uses an R134a refrigerant system. There is also no such thing as an intake valve on any vehicle refrigerant system. There is a high pressure port and a low pressure port. To answer your question: under the hood. Any other information would likely endanger your life, since this is obviously a DIY question and you lack the knowledge to safely recharge your vehicle's refrigerant system. R134a refrigerant, if inhaled, can kill you. Do not turn a DIY project into a DIE project. Leave the complicated stuff to the professionals.
Q:Will A Stop Valve Switch Off Water In The Bathroom Only
Only water what is still in the pipes will come out but you will lose all your hot water in the hot water cistern if you have that type of hot water storage tank.
Q:Butterfly D371X5-16ZB1 what does each letter stand for?
Daily valve pressThe regular model is out of step with you. I can only explain the regularD371X5-16ZB1D is butterfly valve3 is the turbine drive7 is the clamp connection1 is the display opening signX is a rubber seal16 is 16 kg pressureI don't know the other superfluous letters
Q:Butterfly valve flow direction is single or two-way?
The arrow on the butterfly valve is the medium direction of circulation, generally double eccentric, and the three eccentric butterfly valve has the arrow in this direction.The butterfly valve, the valve direction and fluid flow direction should be consistent, we use the butterfly valve is in accordance with the arrow direction and flow direction of the installation.If the arrow is marked on the valve body, it must be installed in its direction. If it is marked on the handle, it means open. Depending on the internal structure, it is possible to have the installation direction required.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range