DN220 Spectacle Plate for IHI Concrete Pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
1000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:


Product Description:

Product Name: DN220 Spectacle Plate for IHI Concrete Pump

1.        Specification

 

Size

DN205DN220

Material

tungsten carbide, Q235B steel, Vautid-150 electrode imported from Germany

Lifetime

30,000-80,000cbm

Carbide HRA

> 86

Electrode HRC

> 63

Type

hardfaced, tungsten carbide and 7 shape tungsten carbide

2.        Application

Spare parts for mud pump, shotcrete,trailer and truck mounted concrete pump

         3.  Package

Plastic bag and carton box, also according to your requirements

FAQ:

Q1: Why buy Materials & Equipment from OKorder.com?

A1: All products have its ISO certifications, adheres to the highest standards and a commitment to supply chain safety and customer satisfaction.

Q2: How do we guarantee the quality of our products?

A2: We have established an advanced quality management system which conducts strict quality tests at every step, from raw materials to the final product. At the same time, we provide extensive follow-up service assurances as required.

Q3: How soon can we receive the product after purchase?

A3: Within three days of placing an order, we will begin production. The specific shipping date is dependent upon international and government factors, but is typically 10 to 30 workdays.

Q4: If we can produce DN220 Spectacle Plate for IHI Concrete Pump according to customers request?

A4: Yes, we can produce DN220 Spectacle Plate for IHI Concrete Pump according to the difference country situations to make it suitable to the market and customers. We have very professional technical team to make the design.

Q5: How to make a quick resolution for after service?

A5: We have overseas branches all-around of world, If needed, the seller shall dispatch 2 engineers to the buyer's site for supervision of training. The buyer shall make available of necessary facilities &skilled personnel at site for training.

 

Images: 

 

 

DN220 Spectacle Plate for IHI Concrete PumpDN220 Spectacle Plate for IHI Concrete Pump

 

DN220 Spectacle Plate for IHI Concrete PumpDN220 Spectacle Plate for IHI Concrete Pump

 

DN220 Spectacle Plate for IHI Concrete PumpDN220 Spectacle Plate for IHI Concrete Pump

 

 



 


 


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the "variable" of a variable pump?
There are many ways to change the variable pump flow: by changing the eccentricity to change the piston stroke length (radial piston pump, the frequency change principle) motor speed to adjust the flow (such as gear pump flow control principle).
Q:How can I buy a pump?
2, must meet the characteristics of the media requirementsFor the delivery of flammable, explosive, toxic or valuable medium pump, requiring reliable sealing shaft or the use of non leakage pump, such as magnetic drive pumps (without shaft seal, using isolated magnetic indirect drive).For the transmission of corrosive medium pumps, convection components are required to use corrosion-resistant materials, such as fluorine plastic corrosion resistant pump.For conveying pumps containing solid particles, wear resistance materials shall be adopted in convection parts, and clean liquid shall be used for shaft seal when necessary.
Q:What is the nominal pressure of the hydraulic pump and hydraulic motor?
Related concepts of hydraulic motorsFlow theoretical volume refers to the volume of oil inhaled in unit time without leakage.
Q:What are the application areas of pumps?
Water pump has different uses, different transmission liquid medium, different flow, lift range, therefore, its structure form is not the same, the material is also different, summed up, can be roughly divided into:
Q:The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
Vacuum pump plus form must not reach a standard atmospheric pressure vacuum, so the general can absorb 8 meters is very good, and the self suction pump itself and loss, the horizontal self-priming pump can suck on basic 4~6 meters is very good, self-priming pump. Suction lift of 30 meters is purely in the Mongolian people, does not comply with the laws of nature, obvious anti science.
Q:Why does the centrifugal pump close the pressure to start?
The flow is zero (i.e. off dead) minimum, the highest lift power; with the outlet valve opening increases, flow increases, the lift, power and efficiency are increased, the maximum value (usually in the vicinity of the highest rated flow point)
Q:What are the problems that should be paid attention to when using vacuum pumps?
(14) vacuum pump used in the winter season, after stopping the pump body, lower drain plug unscrew medium on the net. To prevent cracking.(15) the vacuum pump has been disabled for a long time. All the pumps should be taken apart and dried. The rotating parts and the joint should be coated with grease and properly preserved.
Q:Advantages and disadvantages of centrifugal pumps?
The uniform liquid no pulse phenomenon.(2) shortcomingsBefore running, the pump must be filled with liquid.For the supply of small flow, large pressure head inappropriate, inefficient and limited.Encountered imperfect design or operation is not at the time, such as milk, it is easy to produce foam, affecting the next process production.The installation is wrong. There will be "Qi tie" phenomenon.The efficiency is also lower than the reciprocating pump.The sources of knowledge are absolutely reliable!!!!
Q:Harm of air pump and pump
Centrifugal pump situationEmpty pump is divided into two kinds, if there is no liquid, then it will cause the mechanical seal of the pump to overheat, wear and even die
Q:What are the basic technical parameters of the pump?
The basic parameters of the pump, the basic parameters of the main performance parameters of pump are the following: first, water pump flow Q flow is the amount of liquid in the pump unit time delivery out (volume or quality). The volume of flow with Q that the unit is: m3/s, m3/h, l/s and so on. The quality of flow unit is expressed in Qm. T/h, kg/s and so on. The relationship between mass flow and volume flow is Qm= P Q density in P - liquid (kg/m3, t/m3), room temperature water P =1000kg/m3.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range