Description of 22KW Vector Control Converter Frequency
22KW Vector Control Converter Frequency is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features of 22KW Vector Control Converter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control
2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure of 22KW Vector Control Converter Frequency
Application of 22KW Vector Control Converter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.
★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance of 22KW Vector Control Converter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q: How do I protect the inverter when the three-phase two-pole motor is running?
- Three-phase two-pole motor running inverter protection, should be based on the protection of tips, check the corresponding manual to deal with. When the inverter protection has a corresponding protection tips (such as over-current, over-voltage, speeding, stall ... ... etc.), the product manual will generally give the corresponding protection tips. According to these measures to check, deal with, you can solve the problem.
- Q: Notebook power adapter on how to look at power
- It should be noted that there are many in Japan to buy a notebook or over there in the parallel imports, input only support 110V in China is not used, because the Chinese standard is 220V. Now the subject is 90W 20V. Output voltage and power will be identified, such as the target for the 90W 20V, that output power is 90W, the output voltage is 20V. If only the output voltage and output current are identified,
- Q: Pump frequency converter instantaneous restart and restart the problem
- Inverter speed: Based on the advantages of speed control, energy saving and reliable operation, the frequency converter has gradually replaced the traditional variable speed, electromagnetic speed and voltage regulation. In the introduction of PWM flux vector control of the inverter a few years later, the end of 1998 and the emergence of DTC control technology inverter. ABB's ACS600 series is the first generation of DTC technology using the inverter, it can open the ring speed and torque for accurate control, and dynamic and static indicators have been better than PWM closed-loop control indicators. Direct torque control to measure motor current and DC voltage as input to the adaptive motor model. The model produces a set of precise torque and flux actual values ??every 25μs. The torque comparator and flux comparator compare the actual values ??of torque and flux with the reference values ??for torque and flux to Determine the optimal switch position. It can be seen that it is through the torque and magnetic flux measurement, instantly adjust the inverter circuit switching state, and then adjust the motor torque and magnetic flux, in order to achieve the purpose of precise control.
- Q: The inverter is running independently
- . Main working circuit (1) Operation circuit: the external speed, torque and other instructions with the detection circuit current and voltage signal comparison operation, determine the inverter output voltage, frequency. (2) voltage and current detection circuit: isolation with the main circuit potential detection voltage, current and so on. (3) drive circuit: drive the main circuit device circuit. It is isolated from the control circuit to turn on and off the main circuit device. (4) speed detection circuit: mounted on the asynchronous motor shaft speed detector (tg, plg, etc.) signal for the speed signal into the operation loop, according to the command and operation can make the motor running at the command speed. (5) protection circuit: the detection of the main circuit voltage, current, etc., when the overload or over-voltage and other abnormalities, in order to prevent the inverter and asynchronous motor damage
- Q: Delta VFD-F frequency converter how to adjust the number of poles
- Look at the 07 motor parameters, I VFD-F instructions need, then the mailbox sent
- Q: My motor is a low frequency 8 pole motor, about 80W. I would like to choose a frequency converter
- Poor match, the program is unreasonable Current 1.5A, choose a single-phase 220v power supply, 370-500w inverter it
- Q: Inverter principle eff23
- The basic principle of the inverter The inverter is a device that converts the power frequency (50Hz or 60Hz) into AC power of various frequencies to realize the variable speed operation of the motor. The control circuit completes the control of the main circuit, and the rectifier circuit converts the alternating current into direct current and DC Circuit rectifier circuit output smooth filter, the inverter circuit will reverse into the DC power.
- Q: Three sets of batteries (540V) DC power supply U / f inverter.
- It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.
- Q: 400w 6-pole motor should be equipped with much of the inverter?
- 0.75KW just fine, neither waste the inverter resources, but also to meet the occasional overload. And 0.75KW inverter is the standard model.
- Q: First reduce the frequency of about one-third of the test, not the case, then appropriate adjustments!
- And the inverter is connected to the positive and negative bk-dk electrical Han Han device,
1. Manufacturer Overview
Location | Liaoning,China |
Year Established | 2001 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO9001 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | DALIAN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b) Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
22KW Vector Control Converter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1pc pc
- Supply Capability:
- 8000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords