• WHITE FUSED ALUMINA FOR ABRASIVE MATERIALS IN DIFFERENT SIZES System 1
  • WHITE FUSED ALUMINA FOR ABRASIVE MATERIALS IN DIFFERENT SIZES System 2
  • WHITE FUSED ALUMINA FOR ABRASIVE MATERIALS IN DIFFERENT SIZES System 3
WHITE FUSED ALUMINA FOR ABRASIVE MATERIALS IN DIFFERENT SIZES

WHITE FUSED ALUMINA FOR ABRASIVE MATERIALS IN DIFFERENT SIZES

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT or LC
Min Order Qty:
25 m.t.
Supply Capability:
10000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

·         Place of Origin: Henan, China

·         Shape: Powder or Grain size

·         Material: Alumina

·         Al2O3:99.6%min

·         SiO2:0.02%max

·         Fe2O3:0.02%max

·         NA2O:0.25%max

·         Refractoriness (Degree):1770°< Refractoriness< 2000°

·         Model Number:Customer's Requirement

·         Brand Name:CMAX

·         Application:Metallurgy and Refractory

·         Product name: White Fused Alumina

·         Color: White

·         Size:0-1mm/1-3mm/3-5mm/-200mesh/-325mesh

·         Certificate:ISO9001

·         Usage:Fire Resistance Place

·         Type:Raw Refractory

·       Packaging Details:Bags/As costomer's requirement'

 

 

WHITE FUSED ALUMINA FOR ABRASIVE MATERIALS IN DIFFERENT SIZES

 

Quality assurance:

1.On a regular basis or as per your request,we entrust national testing agencies to conduct quality inspections

2. Strictly in accordance with the ISO9001-2008 international quality system standard,we monitor and manage the whole process throughout production,quality testing,and measurement to ensure product quality

 

FAQ:

Q: What kind of payments does your support?
A: T/T, L/C, Cash are accepted.
Q: Do you charge for the samples? 
A: Accordeing to our company policy, the samples are free, you only charge the freight fee. And we will return the freight fee during the next order. 
Q: Can you produce according to customers' design? 
A: Sure, we are professional manufacturer.
Q: Do you have other products?
A: Yes, please check our other products in website.

 

Q:What's the fire resistance test method of doors and roller shutters?
Fire resistance test method of doors and roller shutters: This standard specifies the fire resistance test method for roller shutter doors under standard fire conditions. The method is used to test the fire resistance of the ventilating duct when bearing the external fire (A duct) and internal fire (B duct). Fire resistance test of vertical ducts may be conducted referring to this standard. 1.Test specimen1.1 The test specimen is obtained by cutting from any part of the qualified metal tube unless otherwise relevant standard or mutual agreement specifies the cutting position of the metal tube. 1.2 Length of the specimen: L≈2.5D+50mm (D: outer diameter of the metal tube). The cut surface of the specimen must be perpendicular to the axis of the metal , and the seamed edge of the cut should be round off. Test method GB243-82 of metal tube necking 2. Test procedures 2.1 In the test, punch or press the metal tube into the tapered conical seat (see Figure) with a hammer or press machine, and make it uniformly diminished to the regulated shrinkage X which is calculated according to the following formula: Test method GB243-822 for metallic pipe necking: The inner wall of the seat cover used in the test should be polished, and has certain hardness and is coated with lubricating oil. Its conicity is 1:10, 1:5 or others in accordance with relevant standard provisions. If there is no provision, then adopt the conicity of 1:10. This standard is not suitable for: a) The pipeline whose fire resistance depends on the fire resistance of the ceiling; b) The pipeline with access door, unless otherwise the access door is included into the pipeline and tested together; c) The pipeline with two or three sides; d) Fume exhaust pipes;
Q:Can polystyrene foam color steel plate be used as decorative fireproofing material ?
No, only non-combustible product can prevent fire. Most polystyrene foam boards are flammable which cannot prevent fire. Polyphenyl can only retard flame, highest fire?retardant fire?rating being B1 level. Under the same conditions, fireproof performance of polystyrene foam board will be better because most extruded sheets are made by recycling materials and contain much more impurities which will affect flame resisting property. The second reason is that high temperature in extruded sheet manufacturing technique will decompose part of flame retardants. For B1 level extruded sheet, it is difficult to reach 30 burning oxygen index, while for B2 level, it is hard to reach 32. So polyphenyl board is safer.
Q:What are the common refractory insulation cotton material?
I know less about this, I hope the following will help: Fire resistant thermal insulation material mainly refers to inorganic thermal insulation material and compround thermal insulation material. According to the shape can be divided into: Fibrous finishes, slag wool, rock wool, glass wool, aluminum silicate cotton. ceramic fiber, micro pile of diatomite, calcium silicate, expanded perlite, expanded vermiculite, aerated concrete etc., foam like bubble glass, volcanic ash glass, foam clay, foaming concrete, paste powder polystyrene particles insulation slurry
Q:what's the detailed address of fireproof and thermal inuslation matertial market?
Detailed address of fire insulation materials market is as follows: A: Guangzhou Huatai building materials co., LTD. Address: Guangzhou Tianhe Chepo Road no. 10 B: Address of Donglong building materials market: Guangzhou Tianhe Taian North Road no. 7 C: Address of Huiya building materials trade market : Guangzhou Tianhe Sports West Road No. 109
Q:How long is the fire resistant limit for ultra thin fire retardant coating?
The fire resistant limit of ultra-thin fire retardant coating is 1.5 hours, generally fire resisting time for thin fire retardant coatings does not exceed 1.5 hours. If the time exceeds 1.5 hours, thick fire resistive coating should be uesd. There is no detailed stipulation for ultra-thin fire retardant coating, and the thickness of the inside is the fire resistance limit shall reach certain time(at least). If fire resistance limit is 2.5 hours, the thickness shall be 4.9mm. If the fire resistance limit is 2 hours, the thickness is 3.5mm. If fire resistance limit is 1.5 hour, the thickness should be 1.75mm.
Q:What are the best refractory materials in 2,400 Celsius degree?
It is the purpose that decides what kind of materials you should use. What you have said is 2,400 Celsius degree, right? It is about the fire resistance of the material or the required temperature of it?
Q:Who knows the setting requirements of roofing fire barrier zone?
First, the the minimum of fire barrier width is greater than 30cm, and the thickness should be same to the thickness of the insulation materials. Fire barrier zone insulation board must do the whole area sticking construction with the base wall during the construction. Fire barrier zone insulation board is required to assistant binding by anchor bolt, anchor bolt must suppress the underlying mesh. Second, Fire barrier zone should be set at the upper position of door and window openings, the distance between the low edge of isolation belt and the upper edge of the window must be less than 50cm. The thermal resistance of fire barrier zone must be half than EIFS thermal resistance in the cold northern areas, while the thermal resistance of fire barrier zone must be three times than EIFS thermal resistance in the hot summer and cold winter area. Third, When the fire barrier zone is set on the edge of the window, fire barrier zone at the upper part of the window should do flanging when sticking, flanging glass fiber mesh must exceed 10CM than firebreak insulation board. Flanging network, underlying network and surface network can not be overlapped or butted at the top of the window. I hope you can be satisfied
Q:The manufacturing technique of refractory material
The major components of alkaline refractory material include magnesium oxide and calcium oxide. The commonly used alkaline refractory material is magnesia bricks. The magnesia bricks with 80%~85% magnesium oxide has good resistance to basic slag and slag and higher refractoriness than clay bricks and silica bricks. It is mainly used in open hearth, oxygen blowing of converter, electric furnace and smelting non-ferrous metal equipment and other high temperature equipment. Refractory materials applied on special occasions include high temperature oxide refractory materials such as alumina, lanthanum oxide, beryllium oxide, calcium oxide, zirconium oxide, etc., refractory compounds such as carbide, nitride, boride, silicide and sulfide, etc., and high temperature composite materials, including metal ceramics, high temperature inorganic coating and fiber reinforced ceramics, etc. Consult and find reference for efractory materials production equipment, go to http://hi.baidu.
Q:What are unshaped fire-resisitance materials?
Refractory castable, refractory plastic material, usually classified according to construction and manufacture method, unfired bricks precast block, refractory pressed into material, refractory cast material, refractory coating, refractory ramming material there are many classification methods
Q:What are the additives and recipes of refractory?
SM water reducing agent

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request