valve of china 2100

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:





Quick DetailsStandard or Nonstandard:  Standard Structure:  Gate Pressure:  Medium Pressure

Power:  Manual Material:  Casting Temperature of Media:  Medium Temperature

Media:  Water Port Size:  DN40mm-DN300 Place of Origin:  China (Mainland)

Model Number:  GF4 resilient gate valves:  resilient seat flange


Packaging & DeliveryPackaging Detail: air plastic bag inside/wooden box outside

Delivery Detail: 15-60days


SpecificationsDIN3352 F4 resilient seat flange gate valves

1.size:DN40-DN300

2.medium:water

3.standard:DIN

4.certificate:ISO9001 CE


resilient gate valves

1.size:DN40-DN300

2.medium:water

3.certificate:ISO9001 CE

4.standard:DIN


available medium:water

working temperature:≤80oC


flange dimensions:DIN2501


face to face dimensions:DIN3202F4.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Will A Stop Valve Switch Off Water In The Bathroom Only
Assuming that the stop valves are good, turning them off will stop the flow of water to the sink taps. To test them, turn on the water faucet at the sink, then turn off both stop valves. The water should stop coming out of the faucet. If it continues to drip, the stop valves are defective and should be replaced when you do the job. If this is the case you'll have to shut off the main water valve or a valve upstream of the stops to replace them. Good Luck
Q:butterfly valves d7a1x5
D- valve type (butterfly valve), 7- connection mode (to clamp), A- valve shape mode (A), 1- structure form (vertical plate), X5- valve seat sealant species (Ding Qing, NBR)
Q:Three eccentric hard sealing butterfly valve, why not fit in the end of the pipe?
The sealing ring will hold up. It does not fit in with the flange end of the pipeline, this addition is the most common and convenient pipeline after purge and easily add pipeline.
Q:Electric butterfly valve (not take the lead) what do you mean?
Electric butterfly valve, as its name implies, consists of an electric actuator and butterfly valve, and the customer does not take the lead, that is, without the electric actuator, only the butterfly valve can be provided.
Q:The difference between butterfly valve and gate valve
Its varieties and quantities are still expanding, and the development of high temperature, high pressure, large caliber, high sealing, long life, excellent regulation, as well as multi-function development of one valve. Its reliability and other performance indicators have reached a high level. Disadvantages, there is a certain resistance to the medium. Gate valves are more used in steam pipes and large diameter water supply pipelines, because of the general requirements of fluid resistance is small, the use of gate valve. Valve is hand wheel rotation, stem upward movement. Flow is not the same, the gate valve requires full open. Need a higher installation space, the valve sealing surface has a certain self sealing capacity, its spool by the media pressure closely with the valve seat sealing surface contact, to achieve tight leakage.
Q:What's the meaning of butterfly valve d371po?
According to the provisions of the JB/T 308-2004 valve type programming method:D== butterfly valve3== transmission: worm gear7== connection mode: clip type1== structure: midlinePo== sealing surface material: lining PoPo== propylene oxide (PO)
Q:My eletric hot water tank started spraying water out the pressure valve?
so that should have fixed it I wonder if you needed to replace the stats
Q:What is an ERG valve?
If initially the codes confirmed that the EGR valve grew to become into defective and grew to become into no longer replaced this might smash the o2 sensor. whilst the EGR is caught open simply by fact of carbon strengthen the engine is taking in extra air it is coming from the blistered gases out of the exhaust and re burning them interior the process the EGR. The O2 sensor will examine this gases passing interior the process the exhaust and point out a lean mix of gasoline and could sign the ECM to strengthen the gasoline to the engine.consequently after a time of employing with mistaken mixtures the o2 sensor will fail. My suggestion is to change the EGR and the O2 sensor then highway try the vehicle.then have the codes rechecked. additionally if the engine isn't working mushy this might reason the transmission to act up.verify that the vacuum hose is linked to the modulator valve on the decrease back of the transmission. some transmissions have a working laptop or computer on a separate circuit interior the device and if the engine isn't working solid computer will p.c.. up the incorrect sign and transmission won't shift properly.. solid good fortune oh and the vehicle ECM or computer isn't your difficulty.
Q:What are the butterfly valves models?
Divided by work pressure:(1) vacuum butterfly valve. Working pressure is lower than the standard atmospheric pressure butterfly valve.(2) low pressure butterfly valve. Butterfly valve with nominal pressure PN<1.6MPa.(3) medium pressure butterfly valve. Butterfly valve with nominal pressure PN 2.5--6.4MPa.(4) high pressure butterfly valve. Nominal pressure PN is 10. 0--80.0MPa butterfly valve.(5) ultra high pressure butterfly valve. Butterfly valve with nominal pressure PN>100MPa.At work temperature:(1) high temperature. T>450 degrees C butterfly valve.(2) medium temperature butterfly valve. 120 C
Q:Transformer butterfly valve and pressure relief valve difference
The butterfly valve is usually fitted with an oil immersed transformer between the tank and the radiator to control the flow of oil between the transformer tank and the heat sink. When large power transformers are delivered, the radiators are usually individually packed to reduce transport sizes. The butterfly valve is closed to prevent the outside air or water from entering the transformer tank. When the transformer is transported to the installation site, the radiator is installed on the butterfly valve one by one. When the radiator is installed, the butterfly valve can be opened so that the oil flow between the transformer, the oil tank and the radiator can be circulated, so as to play the role of heat dissipation.When the transformer is running, it is found that when the radiator has seepage, the butterfly valve can be closed to avoid further leakage of transformer oil, and a new radiator can be replaced.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range