SVC Single Phase 220V Voltage Regulator

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Piece pc
Supply Capability:
2000 Pieces per Month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Power

0.5kVA-10kVA(Horizontal)

5kVA-60kVA(Vertical)

Single phase input voltage

70V-130V and 160V-250V

160V-250V

Single phase output voltage

220V and 110V

220V

Accuracy of voltage stabilization

220V±3% 110±6%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Three Phase Four-wire AC Voltage Regulator

Power

1.5kVA-60kVA

Three Phase Input Voltage

Phase voltage 160V-250V;Wire viltage 277V-430V

Three Phase Output Voltage

Phase voltage 220V;Wire viltage 380V

Accuracy of voltage stabilization

2-5%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Application

 

Widely used in the fields of post office,store,elevator,hospital,school,publishing house and stock exchange where normal voltage is in need,and also can be used in the factories of large and middle-scale industrial and mining corp,it is very much suitable for some important devices and supporting single machine.

 

Input voltage

Three-phase four-line system phase voltage:220±20%

 

line voltage:380±20%,or phase voltage:220±30%

line voltage:380±30%(can be selected.Please specify when ordering)

Single-phase:220±20% or 220±30%(can be selected.Please specify when ordering.)

 

Output voltage

Phase voltage:220V Single-phase:220V Line voltage:380V

Output voltage accuracy

1-5%(can be adjusted)Frequency:50HZ/60HZ

Efficiency

≥98%(Power grade over 50KVA)

Ambient temperature

-10~+40°C

Insulation resistance

≥5MΩ

Electric intensity

The voltage for electrical strength and power frequency sinusoidal is 2000V without breakdown and flash over when lasts 1minute

Overload Capacity

It can last 1 minute at the rated current of two times

Wave form Distortion

No additional waveform distortion

Protective function

it offers the protections against over voltage,over current,phase shortage and phase-sequence(The single-phase offers no protection against the phase shortage and phase-sequence)and mechanical failure

Response speed

≤1s(in the condition that the external voltage changes is 10%)

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:3 24V100W lights, I need to use a large capacity transformer (220V change 24V)?
The quality of transformer itself, coupling coefficient, overload capacity, as well as the impact current of the bulb, filament, cold resistance and simultaneous startup factor, it is better to choose the 400VA transformer
Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
General digital multimeter has a capacitor (some of the files with a million capacitance test table of Jack, some use pen)
Q:Why is elevator lighting transformer installed?
1) a lamp shall be installed at the highest and lowest point 0.5m away from the hoistway, and a light shall be installed at intervals not exceeding 7m, and a control switch shall be installed in the engine room and the bottom pit respectively;2) the lighting power supply for car top and hoistway shall be 36V; when 220V is adopted, the residual current action protector shall be installed;3) there is no lighting device for a closed well road with sufficient lighting conditions around the hoistway.
Q:Can the 500 volt lighting transformer be changed into an electric welder?
The structure of the electric welding machine is different from that of the transformer, and the magnetic gap of the iron core can be adjusted so that the welding current can be changed. In addition, the output voltage of the welder is also soft
Q:The transformer zero line has broken, has the result to the household illumination circuit?
The power supply system in three-phase four line zero line is broken, the breakpoint of the single-phase circuit (220V) electrical burn by voltage to 380V. I met, the incandescent lamp suddenly particularly bright then the blow up of internal fuse TV has burned out. So in the three-phase four wire power supply system zero line asked to do repeat grounding in households is the reason.
Q:How many power illuminator can 5Kva 36V transformer drive?
Of course, if you want to bring more is not impossible, but depends on the working conditions, the actual power = nominal power, short time use (to ensure that the transformer temperature rise is not too high) is also available
Q:How many 40W bulbs can be brought into the 1000VA lighting transformer?
Connect 220V method, FireWire 220V terminal, zero line 0 terminal, 380V terminal is not connected.Connect 380V method, A phase 380V terminal, B phase 0 terminal, 220V terminal is not connected.
Q:Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
What you think? Your light is 220V, right. Over 36V, it's better not to live with electricity unless there is good protection
Q:What's the function of the lighting transformer?
Applies to some requirements for safe voltage 24V - 36V lighting sites. Such as: basement, tunnel, dangerous goods warehouse and so on. Then there is the (mobile, temporary) safety lighting for the overhaul.
Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
We have set up stable trading cooperation with customers from the Middle East, South Africa, North America, Europe and other areas worldwide. We gain a good reputation among customers and lay solid foundation for our development. And we believe that we can be your faithful friends and reliable partner forever.

1. Manufacturer Overview

Location Shanghai, China
Year Established 2008
Annual Output Value US$50 Million - US$100 Million
Main Markets South America
Eastern Europe
Southeast Asia
Africa
Oceania
Mid East
Eastern Asia
Western Europe
Central America
Northern Europe
Southern Europe
South Asia
Domestic Market
Company Certifications CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shanghai Port,Ningbo Port,Guangzhou Port
Export Percentage 81% - 90%
No.of Employees in Trade Department 6-10 People
Language Spoken: English, Chinese, Spanish, Arabic, French, Russian
b)Factory Information  
Factory Size: 3,000-5,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Average