Single Core and multi-core PVC Insulated and PVC Sheath Cable 450 /750 V BVV

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
3000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Single Core and multi-core PVC Insulated and PVC Sheath Cable 450 /750 V Production Introduction for Single Core and multi-core PVC Insulated and PVC Sheath Cable:

Voltage Rate: 300/500V, 450/750V

Cores: 1~5 cores

Range of Nominal cross section: Single core: 0.75 mm2 ~ 630 mm2

                                        Multicore core: 0.75 mm2 ~ 120 mm2

Conductor: Class 1/2 Plain annealed copper wires, solid or stranded

Constructions: Insulation: PVC

            Sheath: PVC

Core color: Brown, Grey, Black, Blue, Green/Yellow or others on request

Max. Operating Temperature: 70, can be 90,105as per requirement

Packing: 100 meter/roll for small size, wooden drum for big size, or as per requirement

 

Application for Single Core and multi-core PVC Insulated and PVC Sheath Cable:

These cables are used for general purpose, as building wire for power, lighting and control wire to electrical appliances, suitable for use in conduit and for fixed, protected installation.

 

Production Standard for Single Core and multi-core PVC Insulated and PVC Sheath Cable:

I EC 60227, GB/T5023, VDE0281, BS6004

 

The  Feature for Single Core and multi-core PVC Insulated and PVC Sheath Cable:

The cable can be of flame retardance, fire resistance and other property

 

Packing photo for Single Core and multi-core PVC Insulated and PVC Sheath Cable:

 

Single Core and multi-core PVC Insulated and PVC Sheath Cable 450 /750 V BVV

Single Core and multi-core PVC Insulated and PVC Sheath Cable 450 /750 V BVV


FAQ For Single Core and multi-core PVC Insulated and PVC Sheath Cable:

 

Q1:What is the Production Capacity for your factory?

About 50 kilometer every day

 

Q2: What is the Minimum Order Quantity For Single Core PVC Insulated Cable 450 /750 V?

MOQ: 10000 meters for small size, 5000 meters for middle size, 1000 meters for big size

 

Q3:What is the delivery time for these cables?

10~15 working days

 

Q4: What standards is the product complying with?

    We can produce thousands of electric wires and power cables complying with different standards, such as: GB, JB , IEC, BS, AS/NZS, VDE, UL ETC.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Home improvement, the wire specifications generally how to choose? Lighting, sockets, air conditioning with a few square lines? Ground specifications can be lighter than the line of fire, zero line?
Dual-screen display expansion, but it is estimated that the graphics card is not too small to see the movie line also play the game at the same time ~!
Q:How to effectively reduce the cost of car wiring harness?
5mm, that is 100: 76 followed by the proportion of push The height of the isosceles triangle at the time of the bend of the 200 high bridge is also suitable for the adjustment of the 90 ° bend; the use of the tool is cut off and the bending of the bridge is 90 ° Bridge elbow As for the length of the bridge to limit the restructuring of the elbow, as long as the use of junior high school learned by the simple mathematical knowledge of the calculation, any length distance can be controlled The use of mathematical methods simple calculation, a variety of angles, the length of the elbow can be made zuo
Q:Calculate the control cable under what circumstances the cable terminal needs to be calculated
This is the air defense when the air pipe laying through the mouth of the closed wall or the protection of closed wall approach, regardless of the side of the wall or the roof into the line have this requirement
Q:Power cable inspection, how many meters should be sampled?
in the wide-linked pricing software GBQ40 to achieve, directly enter the corresponding quota, click on the quota below the" standard conversion ", the cable laying five core check , You can achieve the fixed sub-sub-multiplied by the coefficient of 13 For example: YJ - cross-linked polyethylene insulation (insulation) V - PVC jacket (outer jacket) did not mark the conductor material that is the default copper wire, if the aluminum wire should be YJLV4 * 70 + 1 * 35 core (Mm ^ 2) + Neutral core (indicated by "1") × Neutral core cross section (mm ^ 2) CT - Indicates the cable tray in the laying mode
Q:110 voice patch panel directly to the telephone line can be connected to it
See home improvement or tooling, home improvement we will be buried in the trench below the pipe. Also need not particularly out of the picture, not so high demand. All the lines of the tooling must take the bridge, that is, from the ceiling to go, must be strong and weak to separate a distance, the line can not exceed 40% of the tube (tooling home improvement) to no longer clear the label is not OK, simply can not repair. And this is the national norm. Of course, the construction process of a lot of strong power or take the ground, but this is inside the floor. Can be drawn directly.
Q:How long is the service life of the cable?
cable bridge and other pipes and other facilities shall not share a column (bracket)
Q:Engineering materials inspection, all types of cable wires should be issued a test report?
That is to tell you the code, then you will not do now you have to do the password
Q:Power cable casing buried what are the requirements
2 direct laying cable way, should meet the following requirements: 1 cable should be laid in the trenches, and should be along the length of the cable on the next, next to the side of the shop with a thickness of not less than 100mm soft soil or sand 2 along the length of the cable should cover the width of not less than 50mm on both sides of the cable protection board, protective board should adopt concrete 3 urban cable buried in the laying, it is appropriate in the protection board laying eye-catching signs 4 in the suburbs or open areas, along the cable path of the line spacing of 100m, corner or joint parts, should be erected obvious signs or signs 5 when the use of cable through the corrugated pipe laying in the trenches, should be along the full length of the bellows casting thickness of not less than 100mm of concrete, the width should not be less than 50mm outside the tube, the cable can not armor 3 buried in the non-frozen soil area, the cable embedding depth should meet the following requirements: 1 cable to the basement of the basement structure, not less than 03m 2 cable skin to the ground depth, not less than 07m; when located in the carriageway or farmland, should be properly deepened, and should not be less than 10m 4 buried in the permafrost area, should be buried below the permafrost layer, when not buried can be buried in the soil drainage of dry frozen soil or backfill, but also take other measures to prevent damage to the cable The 5 Directly laying the cable, is strictly prohibited in the underground pipe is just above or below The minimum distance between cable and cable, pipe, road, structure, etc shall be in accordance with Table 535 Table 535 Permissible minimum distance between cable and cable, pipe, road, structure, etc (m)
Q:What is the cable for the YJV33 cable?
If there is a mutation in the target fragment, all the dideoxy-terminated fragments that are larger than a certain size corresponding to the mutant position have no wild-type system, and the rate of detection of mutations is improved for each occurrence of multiple changes in the mobility The ddF method overcomes the difficulty of SSCP analysis due to the effect of DNA length on SSCP, and produces a specific single stranded DNA by a dideoxycyclic acid to show that the DNA fragments with suitable length indicate SSCP changes
Q:Power cable yjv22-10kv-3 * 50 what it means
This model is called copper core XLPE insulated PVC sheathed steel tape armored 3 core, each core conductor size 50mm. the cable voltage is 10KV cable. YJ: cross-linked polyethylene, cable insulation material for the chemical cross-linked polyethylene V: PVC, cable inner jacket material for the PVC jacket material first 2: plating Zinc steel strip, cable armor layer material for the galvanized steel strip Second 2: PVC, cable outer jacket material for the PVC sheathed material 10KV: that the use of the voltage of the cable waiting for you 10 kV 3 * 50 : That the cable is 3 core, each core conductor section 50mm2

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range