• Led Single Color Switch Dimmer DC12V LT-3200-6A System 1
Led Single Color Switch Dimmer DC12V LT-3200-6A

Led Single Color Switch Dimmer DC12V LT-3200-6A

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
12 Pieces pc
Supply Capability:
10000 Pieces per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Brief introduction

 

LT-3200 series LED intelligent dimmer is dedicated to adjust the brightness of LED lights, which adopted the most advanced PWM (Pulse-Width Modulation) digital brightness-adjusting technology at present, users can either operate manually or use the IR wireless remote controller to control the brightness in the distance, they are suitable for commercial and household 86-style socket installation, the socket can be installed outside or inside the wall. LED intelligent dimmer can meet different brightness requirements at different time, and can extend life tenure of LED, suitable for adjusting the brightness of both low-power and hi-power LED illumination lights, energy-saving.

 

Performance Features

1,0~100% brightness adjust, infinite knob style dimming+ wireless IR remote dimming, easy to operate;

2,256 grey scales, soft & smoothly, without flicker.

3,25%,50%,75%,100% 4 DIY modes, fast adjust.

4, 4 DIY modes, with Fluorescent Indicator & delay off button, users friendly.

5,When load of constant current/voltage is beyond, add extra repeater to expand power.

6,Three types available, suitable for LED lamps in different circuits.

 

Input voltage DC12~48V

Output signal Constant voltage PWM

Max load current 6A

Max output power 72W/144W/216W288W

(12V/24V/36V/48V)

Dimming range 0~100%

Scale levels 1024 levels

working temperature -30°C~55°C

Q:Why can't autotransformer be used as transformer for safety lighting?
The transformer of the lighting circuit is a step-down transformer (general input 10kv., 220V). The first coil of the autotransformer is shared and connected together
Q:Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
If the transformer is not calculated, the loss is the same. If the calculation is the latter, save electricity.
Q:Is the substation separate from the power and illumination transformer?
There is only bus in the substation, and the station is connected with the transformer from the bus. If there is no electricity even in the bus, then the substation should not be considered active.
Q:The transformer zero line has broken, has the result to the household illumination circuit?
The zero line is connected to the transformer neutral point of transformer, three FireWire for its voltage is 220 volts, according to regulations, the total can not take the zero line fuse, switch, because once the zero line is disconnected, the rest of the line will no longer be a neutral line, into the use of electrical appliances connected to two the conductor, according to the characteristics of series circuit, each phase with electrical voltage, on load distribution, change the original load smaller which phase by using electrical appliances, will damage due to excessive voltage.
Q:How to calculate the rated capacity of small transformers for lighting purposes?
But in fact, consider the total load, the importance, the location of the machine, and the future additional plan, according to the following order.
Q:Lighting, lights, transformers, bulb brightness is too low, what's the matter?
Line light for safety light, voltage 24 volts and 36 volts, pay attention to the bulb and transformer voltage matching.
Q:What transformer can be used in a safety voltage lighting transformer?
220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
Pe=19.5KW, installed capacityKx=1 coefficient of demandPjs=KxPe=19.5KW, calculated loadCOS, phi, =0.85, power factorIjs=KxPe/3/220/cos phi (Ijs calculates current, voltage, 380V/220V, three-phase)=1*19.5*1000/3/220/0.85=34.76A
Q:Can the 500 volt lighting transformer be changed into an electric welder?
500 VA transformer should not be used as an electric welding machine, so it is very difficult to reform the system, so it is better to buy a new electric welder
Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
General digital multimeter has a capacitor (some of the files with a million capacitance test table of Jack, some use pen)
We insist on "Good faith, Technical Innovation" management concept and take customer's demands and product innovation as our goals. we can create value for our customers as well as offer the first-class quality products and the best solutions to them.

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2003
Annual Output Value
Main Markets
Company Certifications 2009 China Lighting & Electrical Appliance Contest; ISO:9001-2008

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage 61% - 70%
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size: 3,000-5,000 square meters
No. of Production Lines 5
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products