• HB Pure Sine Wave Inverter 350 Watt-10KWatt System 1
HB Pure Sine Wave Inverter 350 Watt-10KWatt

HB Pure Sine Wave Inverter 350 Watt-10KWatt

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Piece pc
Supply Capability:
4000 Pieces per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Feature

 

· It can be used as solar inverter or components of solar or wind generator.

 

· It originates that controlled by CPU completely, increasing the stability of good quality, at the same time, it reduces the cost of production, which make the possibility of pure sine wave inverters ( and UPS) entering into the household market come true, it resolved the troubles of power cut completely.

 

· Unique overload design, originate in the seven seas. With the lowest capacity, it can drive the largest impactive loads (such as tube lightings, energy-saving lamps, refrigerator, TV set, air-conditioner, and generator and so on), such usages cannot be achieved by all other UPS and inverters. It creates a miracle in this field and promotes technical innovation waves in this field.

 

· Functions that when the commercial power comes, it will start the unit automatically: when it overloads,it will close the unit automatically; when you cancels the load, it will restore to normal etc. are humanized designs.And it is a real intelligent household uninterrupted power supply.

 

· Full automatic transformer time less than 4ms, even though your computer wont restart.

 

· Protections against output short-circuit.

 

· With powerful and stable recharging function, make sure that in an extremely short time, it will charge the batteries fully. And its over-age recharging current is up to 10 Amps.

 

 

Main Technical Data

 

· Super wide input voltage: 90V-280V and it has a converted switch, when it is 90V-280V, it is used for inverter, but when it is 175V-265V, it is used for UPS. So it is attractive and convenient.

 

· Protection against output short-circuit; against overload, and when you throw off its load, it will turn on the unit automatically.

 

· Functions that when the AC comes in, it will start the unit automatically.

 

· Charge strongly, and its charging current is stable, the average current is 10A.

 

· Output pure sine wave: 220V+/-3%.

 

 

Application

 

Tube lightings, Energy-saving lamps, Refrigerator, TV set, Air-conditioner and generator.

 

 

Specification

 

Model

DC

N.W. 

(Kg)

Shipping W. 

(Kg)

Outside size (Cm)

Shipping size (Cm)

HB-350W

12V

7.6

16.8

37*12.5*19.5

49*45*31

HB-500W

12V

8.1

18.6

37*12.5*19.5

49*45*31

HB-600W

12V

9.5

19.5

37*12.5*19.5

49*45*31

HB-700W

24V

8.9

20.3

37*12.5*19.5

49*45*31

HB-1KW

24V

10.6

22

37*12.5*19.5

49*45*31

HB-1KW

24V

12

26.3

39.5*14.5*21

52*48*34

HB-1.5KW

24V

15.5

33.3

39.5*14.5*21

52*48*34

HB-1.5KW

48V

18.3

20

46*19.5*30

61*35*44

HB-2KW

24V

20.5

22.5

46*19.5*30

61*35*44

HB-2KW

48V

21

22.3

46*19.5*30

61*35*44

HB-2.5KW

48V

23.2

25

46*19.5*30

61*35*44

HB-3KW

24V

27.7

29.8

46*19.5*30

61*35*44

HB-3KW

48V

27.7

29.8

46*19.5*30

61*35*44

HB-3.5KW

48V

34.1

36

46*19.5*30

61*35*44

HB-4KW

48V

34.1

36

46*19.5*30

61*35*44

HB-7KW

96V,220V

78

85

55*25.5*70

70*43*84.5

 

Q:Power and lighting transformers, lighting quality will be affected much?
Corresponding to the transformer power supply, in order to save costs and reduce costs, the choice of AC ignition method is better. Pure resistive load, the power factor is 1. The 3 *100W=300W is the capacity of the required transformer
Q:Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
See whether the lamp power saving, can not see whether it has a transformer, but to see the light efficiency of the lamp, that is, the ratio of light flux to power!Popular speaking, that is, spend the same electricity to see who sends more light!So, when comparing, ask what the light is, then judge again!The luminous efficiency unit is LM/W
Q:Is the substation separate from the power and illumination transformer?
The power and lighting power supply in the substation need not be separated. In a large capacity power plant, the lighting can be electrically powered to ensure that the generator is stopped. The lighting source is often separated from the lighting transformer and powered by other power supplies.
Q:The transformer zero line has broken, has the result to the household illumination circuit?
No, the zero line of the transformer doesn't go through the zero line of the transformer. It is a star connection, and the center point is zero line
Q:Why should lighting transformers be used in factories and mines?
There are two cases. One is the general factories and mines, and the low voltage is three-phase four wire system, and the neutral point is directly grounded. Between the phase line and the zero line is 220V, which can be connected with the illumination load.
Q:How to calculate the rated capacity of small transformers for lighting purposes?
But in fact, consider the total load, the importance, the location of the machine, and the future additional plan, according to the following order.
Q:Does the lighting work properly? Doesn't that power equipment start voltage unstable?
It is not easy to control, the power and lighting and electricity; if the transformer capacity is small, and relatively large power equipment start frequently, voltage stability will be poor, the lamp brightness will fluctuate dramatically, have effect on visual acuity. But as long as the design is reasonable, it has little effect.
Q:Why is the two side of the lighting transformer grounded?
The metal shell transformer grounding grounding protection is called: under normal circumstances is not charged, electrical metal and in the damaged insulation or other circumstances may be charged part (i.e. metal structure and insulation electrical parts part) and grounding wire connected to a reliable way to protect people.
Q:The difference between lighting transformers and control transformers
The lighting voltage is 36 and 12V, the signal lamp is 6V, the control winding is 127, 110V, the one or two insulation, and the two one is grounded.Simple lighting transformers, the two voltage is not so diverse.
Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
Double winding type safety isolating transformer is provided with two windings respectively as input and output (primary) winding (secondary) winding, and between the two windings are insulated from each other, only through the magnetic connection to the power supply, which is the secondary winding and the earth does not constitute a loop, if the use of additional electrical insulation, it should be safety isolating transformer.
Our leading products have obtained Telecom Equipment Network Access License of China Information Industry Department. All our products are qualified and have passed the country surveillance bureau examination. And we believe that we can be your faithful friends and reliable partner forever.

1. Manufacturer Overview

Location Zhejiang,China (Mainland)
Year Established 2000
Annual Output Value US$10 Million - US$50 Million
Main Markets South America; Eastern Europe; Southeast Asia; Africa; Mid East; Eastern Asia; Western Europe
Company Certifications ISO9001 Certificate

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage 51% - 60%
No.of Employees in Trade Department 3-5 People
Language Spoken:
b)Factory Information  
Factory Size: 5,000-10,000 square meters
No. of Production Lines
Contract Manufacturing OEM Service Offered
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords