Freight Elevator

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Unit unit
Supply Capability:
600 Units per Month unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Detailed Product Description

1) Effective and energy-saving

2) Green environmental protection

3) Stable and reliable

4) Space-saving & Low noise

 

Photocell door protection device

Photocell protection safe net are formed at the entrance of the lift, which sensibly detects and responses to

any objects that intrude into the detecting scope. The safety of human and cargoes are guaranteed.

Our lifts boast extraordinary service hours and the operation is highly effective with an energy-saving merit.

With stable & reliable performance, which will become your helpful assistant & best cargo transportation tool.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the meaning of E and F in the elevator?
E in the elevator is an emergency stop, F is fire. Modern elevators are mainly composed of traction machines (winch), rails, counterweight devices, safety devices (such as speed limiters, safety gears and buffers), signal handling systems, cars and hall doors. These parts are installed in the building of the shaft and the engine room. Usually using wire rope friction drive, wire rope around the traction wheel, both ends of the car and the balance of the weight, the motor drive traction wheel to lift the car. Elevator requires safe and reliable, high transport efficiency, leveling accuracy and ride comfort. The basic parameters of the elevator are the rated load, the number of passengers, the rated speed, the car size and the hoist type.
Q:Hello, Hitachi Elevator is often a 38 fault is what reason. There are those cases he out of 38 failure, how to solve?
Hello, Hitachi Elevator is often a 38 fault is what reason. There are those cases he out of 38 failure, how to solve?...
Q:What are the requirements of the fire function of the elevator?
Fire elevator set requirements, there is a complete set of norms. Very detailed, very fine to the. Simply to you to talk about: just upstairs also said the point; have a dedicated button; top should not be greater than one minute; before the room to the outdoor shall not be greater than 30 meters, planting weight shall not be less than 800kg. These are just the most basic features. Its detailed settings, as well as the specific norms, there is a very complete to save. Such as the front room fire rating, the former room position, the front room area, smoke and smoke, the front room of the door, retaining facilities, ladder and car fire design requirements, electrical system, Leopard Mo fire design requirements. and many more. se are not a word or two can be clear, specifically you have to refer to the specification. Specification is not what one person said, is the fire law set, only in line with the norms to pass the acceptance.
Q:What are the doors of the elevator?
1: you are talking about the 6-sided body, one side is the door (car door), or how it will open? 2: each layer also has a door, we called: hall door 3: car door is with the elevator up and down together The car door open, while the mechanical drive to drive the door at the same time open is so simple, you do not understand, you can ask me again
Q:Vertical elevators between the two kamels distance 11m must be installed in the middle of the security door?
Yes, according to the provisions of (1) when the adjacent two-door gate of the gap between the big tiger gong port harboring locust song Wei linked to 11m, during which should be set to a height of not less than 1.80m, width of not less than 0.35m of the well safety door (3) the door should be installed with a key to open the lock, when the door is open without a key to be able to close and lock, after the door locked (after the door is locked) , The key can be opened from the hoistway; (4) the electrical safety device should be provided to verify the door closed
Q:Which elevator requires the driver
The signal-controlled elevator requires the driver to operate the set of controls that are not needed
Q:Rated load 1050KG elevator on the weight is generally how much
The weight of the weight = car weight + half of the rated load is the weight of the counterweight + weight = car + balance coefficient (here take 50%) * rated load of your elevator factory weight is the number of KG ? 1050KG elevator, then the total weight of the total weight of 1.3T ~ 1.4T 酣 households Feng Feng Ju 莶 angle to bring around the ax. (Including the heavy frame). That is 50KG on the heavy block, then need 24-28 pieces. If you do not worry, after loading the balance under the measured coefficient to ensure that the balance between 0.4 to 0.5 can be installed after the can also be added or minus the weight.
Q:What is the meaning of the word inside the elevator?
Each elevator in the meaning of B may be different, such as some B1, B2 ... ... that the ground floor, the second floor of the ground ... ...; some 1B, 2B ... ... that the first floor half, second floor half ... .... So the specific meaning depends on the specific situation.
Q:How to determine the balance coefficient of elevator GB
The balance factor (K) is a familiar and unfamiliar parameter for elevator professionals. It is known because we all know that the traction elevator has a balance of the weight of the configuration, all know that the national standard in the provisions of the balance coefficient should be in the range of 40% to 50%. (1) directly weighing P and W balance coefficient K is not a mysterious parameter. In the final analysis it is to configure the weight of the weight of the weight, so the balance coefficient K is determined by the balance coefficient design value to configure the weight. This method is cumbersome to operate, and the other parts of the weighing is difficult to achieve without omission, generally not applicable. (2) According to the known K value, the weight of the weight is determined from the balance coefficient K. When the load corresponding to KQ / H is loaded in the car, the static moment on both sides of the traction wheel should be balanced. If you know the design value of the balance factor, simply load the load and verify that it is balanced. The easiest way to verify is to release the brake on the mainframe, and use the manpower to feel the torque balance on both sides of the traction wheel on the hand wheel to increase or decrease the weight. (3) According to the existing weight, it is recommended to use the method of measuring the traction motor current on the national standard. The basic principle is: when the elevator for uniform operation, the traction motor shaft output torque converted to the motor shaft, the elevator mechanical transmission resistance resistance torque (referred to as resistance torque)
Q:What is the elevator called?
Back to the first layer of meaning
We have introduced production facilities and inspecting equipments with advanced world levels from Germany, Italy and other countries, so that keeps a manufacturing capacity about 40,000 sets as annual output, which is a large-scale and modern manufacturing enterprise, facing the global market for elevators, escalators and parking system equipments.

1. Manufacturer Overview

Location Zhejiang,China (Mainland)
Year Established 2007
Annual Output Value Above US$100 Million
Main Markets 90.00% Domestic Market
2.90% Southeast Asia
2.10% Eastern Asia
1.50% South America
1.20% South Asia
1.00% Africa
0.60% Mid East
0.50% Central America
0.20% Oceania
Company Certifications Machine Roomless Passenger Lift CE Certificate; Passenger Lift CE Certificate

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shanghai port
Export Percentage 11% - 20%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese, German
b)Factory Information  
Factory Size: Above 100,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Average