Product Description:

Along with the rise of LED illumination, LED lamps are widely used in hotel, business center, household decoration etc., there are more and more chances to use LED and fluorescent lights at the same project, if LED lamps and fluorescent lights can be controlled together by a traditional fluorescent dimming system, it will make everything more convenient, but the dimming principles of LED and traditional fluorescent lights are different, LED lights can not be dimmed by the fluorescent dimming controller directly.

 

As a fact of that, our company developed a new 0-10V to PWM dimming driver which has solved the compatible problem of fluorescent dimming system. and LED illumination, LED lamps can be controlled by many traditional intelligent dimming system.

 

NOTE: The CV Dimming Drive and CC Dimming Drive can be connected together on the same dimming system, which is convenient for controlling different LED lamps with different voltage and power. Signal input and output of 0-10V dimming driver have security protection function with photoelectricity isolation 5KV

 

Product parameter

Input voltage DC12V~DC24V

Max load current 10A/CH×1

Max output power 120W(12V)/240W(24V)

Input signal 0-10V analog dimming signal

Output signal PWM LED dimming signal

working temperature -30°C~55°C

Dimension L121×W39×H39(mm)

Package Size L123×W42×H42(mm)

Weight (G.W) 85g

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
If there is no painting can be used with a diode symbol file (measuring probe connected to the capacitor to hear a sound if the table does not ring at the table and then the general display is 1, then the pen on the emergence of the phenomenon that the capacitance is still good. If one table has been ringing that received the capacitor capacitor breakdown is broken)
Q:How many A leakage protection switches are used in 5000VA lighting transformers?
Line lighting transformer is suitable for AC circuit of 50~60 (Hz). It is widely used in electronic industry or industrial and mining enterprises, mechanical equipment, general circuit control power supply, safety lighting and indicator light power supply.
Q:Can the 500 volt lighting transformer be changed into an electric welder?
The structure of the electric welding machine is different from that of the transformer, and the magnetic gap of the iron core can be adjusted so that the welding current can be changed. In addition, the output voltage of the welder is also soft
Q:Is the substation separate from the power and illumination transformer?
There is only bus in the substation, and the station is connected with the transformer from the bus. If there is no electricity even in the bus, then the substation should not be considered active.
Q:Our power lines and lighting lines are connected to the same transformer. Is there any effect?
As long as the capacity of the transformer is enough, the voltage fluctuation of the line will be sure to occur when the high power equipment is started. Such fluctuations do not have much impact on the lighting.
Q:The transformer zero line has broken, has the result to the household illumination circuit?
When the zero line break line is not broken, the voltage drift of the point voltage leads to the rise of the 220V branch voltage and the reduction of the 220V branch voltage
Q:How many 40W bulbs can be brought into the 1000VA lighting transformer?
Connect 220V method, FireWire 220V terminal, zero line 0 terminal, 380V terminal is not connected.Connect 380V method, A phase 380V terminal, B phase 0 terminal, 220V terminal is not connected.
Q:Why can't autotransformer be used as transformer for safety lighting?
When a fault occurs, leakage of electric leakage occurs, and the original coil is transmitted to the residents at high voltage, causing disastrous effects on the human body and property!
Q:Why is the two side of the lighting transformer grounded?
In the three-phase transformer, the neutral point of the three-phase transformer and the metal case are always reliably connected, and the utility model has the advantages of reliable grounding, both working grounding, protection and earthing, and protection of personal safety and equipment safety.
Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
We insist on "Good faith, Technical Innovation" management concept and take customer's demands and product innovation as our goals. we can create value for our customers as well as offer the first-class quality products and the best solutions to them.

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2003
Annual Output Value
Main Markets
Company Certifications 2009 China Lighting & Electrical Appliance Contest; ISO:9001-2008

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage 61% - 70%
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size: 3,000-5,000 square meters
No. of Production Lines 5
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range