Copper Clad Aluminum Magnesium Wire

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

CCAM Wire
1.Better price with same characteristics against pure copper wire
2.Better tensile strength and elongation

Main Techinacal Parameters

Technical CharacteristicsCCAM wire
Clad typePlated type
15H15A
Size range0.12-8.00.12-8.00.12-6.0
Copper content34-4034-4010
Tensile Strenghth≥220150-210180-250
Elongation155
Conductivity555537
Resistivity0.0308590.0308590.047
Density3.633.632.85


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Emergency cable T-box and cable distribution box of the information?
Cable distribution box according to its electrical composition is divided into two categories: one is not any switch equipment, the box only the cable end of the processing and connection of the attachment, the structure is relatively simple, smaller, more functional , Can be called ordinary distribution box; the other is not only the general distribution of the box annex, but also contains one or more switchgear, its structure is more complex, larger, more connected devices, manufacturing technology Large, high cost, can be called advanced distribution box
Q:What is the difference between VV22 and VV62?
Cross-linked power cable heating the main reason there are . the choice of continuous allowable current is less than the load of the maximum continuous current power cable; . the power cable in the implementation of the cable for cold contact, the use of crimping pliers die too large, leading to copper . the air switch input and output and cable copper nose connection, the choice of non-standard flat gasket or no spring gasket; . the air switch input and output side of the cable and cable core crimp is not solid and reliable; When the cable is connected to a strand, the air switch bolts are not tightened. . high-power UPS running, the filter cabinet is not put, n harmonic effects of cable overload, neutral overload, serious lead to cable breakdown, and a fire hazard. . the power cable along the building facade iron cabinet box laying, the surrounding environment is not ventilated, poor heat dissipation. Select the power cable should consider the following factors: . the rated voltage of the cable is greater than or equal to the rated power supply system power supply system; . the cable can continue to allow the current to be equal to or greater than the maximum load current load; . Power supply system short-circuit stability requirements; . according to the length of the cable to determine whether the voltage drop to meet the requirements; . the end of the line minimum short-circuit current should be able to protect the device reliable action. . a high degree of breakdown strength; . low dielectric loss; . a very high insulation resistance; . excellent resistance to discharge performance; . with a certain degree of flexibility and mechanical strength; . long-term stability of insulation.
Q:How to convert the computer's audio and video to cable TV signals. Through the cable television transmission to the 40 TV (hurry)
In general, a 42U cabinet to 200 information points within the appropriate
Q:Is the power cable considered a fixed asset?
Is fixed assets fixed assets - machinery and equipment - conductive equipment
Q:What is the meaning of "cable tray: 200 * 100 middle strip" in electrical engineering
Two should be phase line, generally in the three-phase loop corresponding to the color: A phase is yellow, B phase green, C phase red, neutral (that is, zero line) for the blue. If only in the single-phase loop only red and green when the default is red for the phase line, green for the zero line. But not necessarily, some electricians do not follow the requirements, the specific you have to use the pen to know what the
Q:110 voice patch panel directly to the telephone line can be connected to it
sure. Take the ground pipe is to be from the floor under the brick. But the late completion of the drawing to be accurate, so that the next time to repair the line can not find the location. Want to answer to help you.
Q:With a i3-2100 desktop computer about how much money. To have a separate graphics card. Give a configuration alone, no more than 4000
The length of the cable bracket is determined by how much the cable is
Q:Power Cable Check Well b-type covers show what?
A grade steel fiber concrete inspection covers are used for airports or special roads and venues for expressways that can take off and land for helicopters
Q:What are the varieties of wire and cable (detailed point)
Chien fiber optic transceivers fiber optic cable flange fiber box fiber jumpers welding machine. Our company: Qin Sheng network
Q:Power cable yjv22-10kv-3 * 50 what it means
10kV XLPE insulated steel tape armored PVC sheathed power cable three core 50mm2

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range