• Butterfly Valve Without Pin Ductile Iron DN100 System 1
Butterfly Valve Without Pin Ductile Iron DN100

Butterfly Valve Without Pin Ductile Iron DN100

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
50 set
Supply Capability:
50000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Centerline structure,pinless double half shaft design.
Disc has two-way bearing, no installation direction requirements.
Non-backed replaceable seat with good performance and a longer working life.
Square and short neck for lable use and cost saving.
Easy installation, no need flange gasket.

 

SizeDN50mm-DN600mm
Design standardAPI609/EN593
End flangeDINPN10/PN16, BS4504PN10/PN16, ANSI class125#/class150#
Face to faceAPI609/EN558-1
Top flangeISO5211
BodyDuctile iron/Cast iron
DiscDuctile iron/CF8/CF8M/C95400/C95500
StemSS420
SeatEPDM/NBR/Viton/PTFE
ActuatorBare shaft/Lever/Gearbox and handwheel
CoatingEpoxy/Nylon/PTFE
PinWith out pin
Suitable mediumWater/Seawater/Sewage/Air/Foodstuff/Oil

 

 

Q:How to connect the signal butterfly valve?
If you mean the signal of fire water supply system, there are generally three outlets, one public, one open and one off. Fire control system signal butterfly valve is normally open, so the signal butterfly valve to open position, with a multimeter to measure the 2 lines, the 2 lines into the input module is fine.
Q:What is the difference between wafer (flangeless) type and LUG type of butterfly valves?
WAFER butterfly valve is the valve is divided into LUG (ears) with and without LUG, ordinary LUG without clip on 12 points in the direction of valve is generally two to four bolt holes was not, whereas the LUG of butterfly valve cross dispersed in a circle. Bolt hole. With LUG all bolted through the LUG, so that the butterfly valve and the clamp on the two flange connection is more solid, you check the valve picture, it is easy to understand
Q:That industry uses most of the butterfly valve, and only use the butterfly valve, a large number of use of butterfly valve, seek expert advice!
Large diameter heating pipes with more than butterfly valves, greater than or equal to DN600 are used butterfly valve
Q:What's the use of fire butterfly valve?
You should ask the signal butterfly valve, butterfly valve in the fire signal system which is a monitoring alarm signal, its purpose is to ensure that the valve has been opened in the daily state, to prevent misuse operation was closed, thus affecting when accidental fire extinguishing. Therefore, it is necessary to set up the signal valve!
Q:Butterfly valve is the control valve?
The flow characteristics of butterfly valves can be approximately equal percentage characteristics, with the positioner can do adjust, is mainly used in large caliber, straight stroke control valve more than 200 volume weight will be great, it suggests using the butterfly valve.
Q:I have a 1993 Oldsmobile Cutlass Supreme and I think I have the case of the blow-by. The engine had high mileage, but was rebuilt b/c it stalled while driving. 3.1L V6 gasoline engine. The fuel filter and the fuel pump are brand new. Now we have the same problem a few months later. It stalls while driving. Its been sitting a while and won't start by itself, so I pulled off the air intake hose off of the air filter to spray starting fluid into it. I noticed oil puddled in the air intake hose, so I looked for the PCV valve on the rocker cover. There is a tube going from the air-intake hose to the rocker cover. I popped out the tube from the rocker cover and there is no PCV valve. Just tube. Is that where the PCV valve is supposed to go? If not, where can I find it on the engine? And could that possibly fix the blow-by and the stalling engine? I'd appreciate any help. Thanks in advance.
top of the manifold
Q:How warm is the PTFE butterfly valve?
Ordinary PTFE clip butterfly valve normal temperature tolerance of about 120 degrees, instantly to about 150 degrees
Q:The difference between the directly buried gate and the flange valve and butterfly valve
Buried gate also called buried gate valve, valve can be directly buried underground, built without manhole, reduce road excavation area; small well maintained road and beautiful room can reduce the difficulty of construction, reduce project cost. The directly buried soft sealing gate valve is divided into two types: telescopic type and fine fixing type, wherein, the telescopic type is divided into metal type and plastic type. In the process of construction, the telescopic type can be adjusted arbitrarily according to the distance between the buried depth of the valve and the ground, and the micro adjustment can be adjusted on the spot. The directly buried gate valve has the advantages of long-term use, no leakage, no maintenance, etc., and can effectively avoid other people switching the valve and stealing the manhole cover at will.Flange gate valve is connected to the flange gate valve, this connection is the most common way.
Q:How to calculate the size of the manual butterfly valve?
[1] type code, transmission mode, connection form, structure form, sealing surface material or lining material, nominal pressure, valve body material, this is the most basic arrangement way now D341X-16C. [2]: butterfly valve also known as butterfly valve, control valve has a simple structure, can be used for low pressure pipeline valve switching control is closed parts (disc or disc) is a disk, around the valve axis to achieve the opening and closing a valve, the valve can be used to control the air water, steam, and all kinds of corrosive media, mud, oil, metals and radioactive liquid media and other types of fluid flow. On the pipeline, mainly from cutting and throttling. Butterfly valve headstock is a disc shaped disc, in the valve body around its own axis of rotation, so as to achieve the purpose of opening or closing or regulation.
Q:16 inches below the choice of electromagnetic valve can be the same, it turned out to be DN200 election 1/4, and now there are DN350 can also use this? With it, limiter, pressure relief valve, locator model will change?
The valve (including the valve, butterfly valve, etc.) are equipped with pneumatic actuators are standard (including restrictor valve positioner of the electromagnetic valve is connected with the installation.) is the international standard NAMUR standards, in the standard of inside electromagnetic valve is G1/4, of course, this is the solenoid valve installation in the NAMUR interface of the driver on the situation, if the solenoid valve is not installed on the drive, but through the trachea installed in a few meters away, it would have to choose a larger size, how to choose? Depends on the switching speed of the valve requirements, such as drive gas consumption is 2L, need to open in 1S, the electromagnetic the valve requires the flow of 120L/min, plus the line loss and acceleration, 500L/min is enough.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords