8.7/10kV,8.7/15kV XLPE ,3c185m2unarmoured power cable,elctrial cable wire
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 200 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
MV 8.7/10kV,8.7/15kV,Cu/XLPE/CTS/PVC
----unarmoured power cable
-----3x185mm2,3x185sqmm
XLPE insulated PVC sheath power cable
Conductor:copper(aluminum is also ok!)
Insulation:XLPE
Nominal voltage: 8.7/10kV,8.7/15kV
Sectional area:3cores x 185sqmm,3cores x 185mm2
Armoured or not:Not
CTS:Copper Tape Screen
Sheath:PVC
Used for power transmission and distribution line with voltage rated at 35kV and below.In comparison with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working
The standards
The power cable is mainly complying with IEC 60502,IEC60840 standard, also can be produced according to OEM requirements and other standards, such as BS, DIN, ASTM, VDE, NFC standards, and so on.
PS:We can also manufacture as follows
Medium voltage cabel power cable:
3.6/6kV,6/6kV,6/10kV,8.7/10kV,8.7/15kV,12/20kV,18/20kV,18/30kV,21/35kV,26/35kV.
XLPE insulated PVC sheathed power cable (XLPE/PVC Cable)
XLPE insulated steel tape armored PVC sheathed power cable (XLPE/STA/PVC Cable)
XLPE insulated steel wire armored PVC sheathed power cable (XLPE/SWA/PVC Cable)
Flame retardant XLPE insulated PVC sheathed power cable (FR/XLPE/PVC Cable)
Flame retardant XLPE insulated steel tape armored PVC sheathed power cable (FR/XLPE/STA/PVC Cable)
Flame retardant XLPE insulated steel wire armored PVC sheathed power cable (FR/XLPE/SWA/PVC Cable)
PVC insulated PVC sheathed power cable (PVC/PVC Cable) NYY cable
PVC insulated steel tape armored PVC sheathed power cable (PVC/STA/PVC Cable)
PVC insulated steel wire armored PVC sheathed power cable (PVC/SWA/PVC Cable)
Flame retardant PVC insulated PVC sheathed power cable (FR/PVC/PVC Cable)
Flame retardant PVC insulated steel tape armored PVC sheathed power cable (FR/PVC/STA/PVC Cable)
Flame retardant PVC insulated steel wire armored PVC sheathed power cable (FR/PVC/SWA/PVC Cable)
Conductor long-time operating temperature is 90 degrees.
In short circuit, conductor highest temperature should be not more than 250 degrees.
Generally specs:
Number of the cores:Single core and 3 cores
Conductor:copper or aluminium
Insulation:XLPE
Copper tape or copper wire screen
Unarmoured and armoured(Steel tape and steel wire armored)
PVC or PE sheath power cable
- Q:Cable zc_y v22 what does it mean
- No problem with the copper, the home is no problem as if you take a twisted pair as a telephone line KVV with BV material, the process is not much difference in the production...
- Q:if I buy a new 4 pronged power cable how should i install in the dryer,what should i do with the extra 4th wire of the cable,pls help Thanks
- Remove the jumper from the neutral lug, (the center lug), to the appliance chassis. Attach the ground wire to the appliance chassis. The 3 lug terminal hooks up Hot-Neutral-Hot. Make DAMNED SURE the appliance chassis is grounded.
- Q:I have a Parrot Boombox bluetooth speaker but am missing the power cable. Can you look at this picture and tell me what kind it is and where I might get one?
- It is an IEC C7 power connector (unpolarized, but that is pretty much the norm). Also known as a figure-8 or tape recorder connector for largely historical reasons. Any electronics or electrical shop should be able to sort you out - Radio Shack for instance.
- Q:Copper core power cable laying (cable section YJV4 * 35 + 1 * 16mm2) Will the dawn of the software in how the amount of superposition? The Please master instructions, the problem added: YJV4 * 35 + 1 * 16mm2 is not the 4 * 35 + 1 * 16 = 156mm2 copper core power cable laying (cable section 156mm2) to count, more
- That is to tell you the code, then you will not do now you have to do the password
- Q:I've got everything connected to my motherboard, but cant start up my computer until i get these small cables connected to my motherboard. I just want to start up my computer. I've got the cpu in, the cpu fan, ram, speaker,hard drive, floppy etc.. How do i fit the cables in the question above, in the right order so my computer will start. I believe they go into the USB and PANEL on my motherboard.thank you
- There should be an insert that came with your motherboard that shows you where to plug what. Also, read the instruction manual, or at least flip through it until you find a diagram. A third thing you can do is look at the little plugs, sometimes they're labeled right there on the board.
- Q:When I plug and unplug a power cable to the net in my home for let's say, 50.000 times a day, why doesn't my electricity-meter not count that power for the monthly electricity fee?When I unplug the cable the cable should still have some electricity flowing through it at the moment of unplugging. That electricity disappears very shortly after . But after unplugging it, it doesn't have any electricity anymore. So some electricity is lost right? How does this work?
- Basically, the appliance works on the current flowing into it. When you unplug the cable (or hit the OFF switch, same thing) the current stops flowing, then the appliance then stops working. Very simple. .
- Q:can you use a standard molex power cable on a SATA HD or do you have to use a SATA power cable to power it?
- It depends on the drive, some have both some only have one option. Avatarxz
- Q:its a rca home theater system and i need a power cable as my last one broke is there somewere were i can buy one
- Compare it with the one plugged into your computer. Most any store that carries computers or home electronics will have that kind on hand, possibly even a box full of leftovers in the back of the service department. If the cord is thick it's built to carry more power and you should get a similarly rated one to be safe.
- Q:I have a Maxtor 3200 and I accidentally plug in the wrong power cable for it. I saw the light flicker on then off. I realized my mistake and tried to plug it in its correct cable but now it won't turn on at all. I figure that the wrong cable must of forced too much energy through it. I have a lot of important files on there. I know that fixing it won't be cheap, I fully realize that. However, is there any hope of retrieving my files at all?
- You will be able to get your files back as they are magneticly stored on the harddrive not electronicly, as far as fixing it yourself, you could try opening the plastic shell and retrieving the harddrive itself from inside and hook that up to your pc if you know how.
- Q:If Not What Do I Have To Look Out For Because Im Looking For A New Power Supply Fan.
- The power supply fan is normally built into the power supply. If you are trying to replace the fan in the unit, you will have to deal with taking it apart and probably doing some soldering. Be careful to at least match the specifications of the original fan.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
8.7/10kV,8.7/15kV XLPE ,3c185m2unarmoured power cable,elctrial cable wire
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 200 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products