• 50kva - 800kva Trailer Genset Diesel Generator Double Axle 4 Wheels System 1
  • 50kva - 800kva Trailer Genset Diesel Generator Double Axle 4 Wheels System 2
50kva - 800kva Trailer Genset Diesel Generator Double Axle 4 Wheels

50kva - 800kva Trailer Genset Diesel Generator Double Axle 4 Wheels

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

50kva to 800kva Trailer Genset

1. 250kva Cummins ,Perkins and Deuz diesel engine 
2. Volt 220V/380V, 230V/400V, 240V/415V
3.  Double Axle ,4  Wheels


50kva - 800kva Trailer Genset Diesel Generator Double Axle 4  Wheels

 

Specifications:

Trailer Generator with Turn-table

1. Standard: GB/T2819-1995

2. Single Axle and Double Axle Wheels is available.

3. Heavy Duty Reinforced M.S Chassis, with 8 hours base fuel tank

4.High Strength, impact-resistance, anti-deformation

5. Exclusive water resistance structure, inspection windows, maintenance door in each side

6. Flexible connection lug design insure excellent buffer performance

7. Max. workable Speed 40 km/hr

 

Engine Features:

1. World most famous brand diesel engine: Cummins.Perkins . Doosan. etc

2. Mufti-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

 

Soundproof/Slient Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and safety

6. 1m<80dB/7m<70dB/68dB

  

Control Panel Features:

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

Main Functions:

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

  

Warranty policy

Guarantee for one year or 1000 hours whichever reach first from ex-factory date. During the guarantee period, Genor will provide the free easy-damageable spare parts of diesel engine caused by our quality of production or raw material. After expiration, Genor provides cost spare parts maintenance of gensets.

 

 

Q:Does the motor have a good brush or no brush?
The carbon brush looks a bit like a pencil eraser, with a wire on top. There is a lot of small size. As a sliding contact, carbon brushes are widely used in many electrical devices. The products are made of graphite, lipographene, metal (copper, silver) graphite.
Q:The difference between pulse motor and servo motor
But if you ask the difference between the stepping motor and the ac servo or dc servo, I can tell you: Stepper motor start-up needs a slow speed, and can control through pulse, and is inversely proportional to the speed and torque of the motor, the higher the speed, torque is smaller, and the highest speed is not more than 1500 r and his itself has no feedback device, speed up the easy step, and the low speed easy to shake. And other kinds of motor position control (pulse) and speed (analog control) with a feedback device, constant torque under the rated speed, the speed of tens of thousands of turn, and because there are feedback device step will not be lost
Q:What is the difference between explosion-proof motors and ordinary motors?
the excitation control system is reliable by using the brushless excitation, setting the rotary rectifier disc and the static excitation cabinet. It is accurate to be accurate, without impact. The excitation system loses step protection and is reliable, and the whole step is strong. The circuit design is reasonable, the discharge resistance is not hot in the work. Excitation current adjusts the scope width. (3) synchronous machine, ac exciter and rotating rectifier disk coaxial. The rectifying disk is located between the main motor and the exciter, or outside the bearing seat. (4) the hull protection level is IP54. Adopt F class insulation, temperature rise press B. (6) change the traditional water cooling to the upper water cooling, the water cooler on the upper part of the motor. (7) set up an antitide heaters, fixed in the hood of the motor, to be used for heating and moisture-proof during downtime. (8) select the high quality raw materials, electrical and mechanical calculation with a large margin, which can meet the temperature requirements of the running reliability and the increase of an ampere motor. (9) to set up comprehensive monitoring measures; The main junction box is set up for the differential protection of the self-balancing current transformer. The stator winding is buried in the work and the spare platinum-thermal resistance, which is Pt100. A leak monitor to monitor the leak of a water cooler; The two sides of sliding bearings have the on-site temperature display and remote signal terminals. Positive pressure type motor is a type of positive voltage electrical equipment.
Q:How do you differentiate the converter motor from the general motors?
Variable frequency motor and the common one of the biggest difference is the fan cooling way, general motors was the cold, the fan on the motor shaft, changes with the rotational speed of the motor, so the ordinary motor at low frequency heat dissipation is not ideal. Frequency conversion motor cooling fan is behind the motor equipped with a cooling fan, need an external power, the fan will not be affected by the speed of the motor, is a strong refrigeration.
Q:What's wrong with the rotary roller
The machine burns a set of lines, which may be the starting line. 2, the motor card is dead, try to turn by hand. Check the capacitance or change it. The main board is broken, and it cannot detect the starting signal.
Q:The difference between plateau motor and ordinary motor
Elevation of elevation, the breakdown voltage of the electrical clearance is decreased, so the need to increase the electrical clearance in accordance with the sea level. High elevation, the initial voltage of the corona decreases, and the anti-stun measures of the motor are strengthened.
Q:Can I use the servo motor?
Can't use what you have said that four thread is U V W the servo motor controller, servo motor by the pulse signal, the line 9 is the servo motor, photoelectric encoder is to control the servo motor torque, speed and Angle.
Q:What's the difference between a TEFC motor and a regular motor
The TEFC motor is a fully enclosed fan cooled motor, and the TEFC motor is a self-ventilated cold motor. Motors can be used in open or fully enclosed enclosures and can be used in very hostile environments. The air that is used for ventilation (provided by the user) enters the motor through the duct, and the heat is discharged through the duct. Cooling air is used internally or externally. Weather-proof motor is ventilated with open hull. The structure of the motor makes the electric parts of the electric parts that enter the motor, the snow, and the particles in the air to be minimized. The external air can be recycled through the motor to the cooling effect.
Q:What is the difference between an energy-saving motor and a general motor
Ordinary motors are ubiquitous in daily life, but energy efficient generators are also beginning to emerge when energy is highly developed. And more and more people are choosing to save electric motors, so what is the difference between an energy-efficient motor and a regular motor? First, the output power of the ordinary motor is less than that of the energy-saving machine. The output power of the ordinary motor is only 50% of the input power, and the energy-saving motor can reach more than 90%. The next year, power issues. The electric motor will be powered by the power supply, and the energy saving motor will turn on the power and the feet will not use electricity. In a society where energy is scarce, we should conserve energy and save money for ourselves. Energy efficient motors can do that. The performance characteristics of high efficiency and energy-saving motors are introduced as follows: 1. Completely based on domestic raw materials. The method of low uncertainty test is used to calibrate the efficiency of the measured results. Contrast with the normal Y series: losses of 15% to 25% and efficiency up 2.5% to 4%. 4. With the improved ventilation systems using highly efficient energy-saving fan of energy-saving motor air gap, the flux density distribution of reasonable design, make the motor efficiency index reaches more than GB18613-2006 grade 2 energy efficiency standard.
Q:Is the servo motor more than the general motors? Why is that?
Of course, it's not the same, if it's all running at full capacity, but if you have a surplus, the servo motor will be more efficient, after all, the response is fast

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords