size range1/2"~10"
working pressurePN1.6~6.4Mpa, 150~300LB, 10K, 20K
suitable temperature-29~150°C
Suitable mediumwater, gas, oil
CF8(304): suitable for nitric acid
CF8M(316): suitable for acetic acid
Technical Standard
Design StandardASEB16.5a
Facto to face StdASMEB16.10
Pressure-Temperature RatingASEB16.34
End-Flange StdASEB16.5a
Test StandardAPI598, ISO5208
MaterialWCB, CF8(304), CF8M(316)
OperationManaul, Pneumatic, Electric

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Gate valve z11h/y-16 what does that mean?
Product Name: internal thread gate valveItem number: Z11HProduct specification: DN15-50Product pressure: 1.6MPa-2.5MPaMaterial: cast iron, cast steel, stainless steelInternal thread gate valve nominal pressure 2.5Mpa, applicable temperature range -20-232-350, applicable medium: water, oil, gas and certain corrosive liquid (W.O.G), thread type G.NPT.BSPT.BSP.DIN259/2999.
Q:The difference and use of gate valve and stop valve
Standard light valve professionals to answer for you, gate valve refers to the closure of parts (gate) along the central line of the vertical direction of moving valve. The gate valve is mainly used for cutting in the pipeline. The valve is a valve with a very wide, cutting device general caliber DN = 50mm use it, sometimes a small diameter cutting device also use valve, gate valve has the following advantages:Fluid resistance is small.Minor force needed for opening and closing.
Q:What gate valve is the J41H-150LBDN100 gate valve?
J41H-150LBDN100 is not a gate valve, it is a API stop valve.API valve can only medium one-way flow direction when installing. Its structure length is larger than gate valve, and the fluid resistance is large. The reliability of sealing is not strong in long-term operation.Also called cut-off gate valve is the most widely used as a valve, it is popular is because the process of opening and closing the sealing surface friction between the small, more durable, highly open small, easy manufacture, convenient maintenance, not only for low pressure, but also suitable for high pressure.
Q:Why does the centrifugal pump start and stop in the case of closing the gate valve?
The centrifugal pump starts and stops in the case of closing the pump outlet valve. Start off the pump outlet valve is to reduce the starting current, stop when the pump is closed, the outlet valve is to reduce water hammer, prevent blade from bad.
Q:What is the difference between cut-off valve and gate valve?
Simply put, the cut-off valve is one-way, only into, do not give up, the valve is two-way
Q:The difference between cut-off valve and gate valve
Structurally, the gate valve for the gate, down to the front and back seat seal; globe valve with spherical, taper and flat spool, down to the valve seat seal. Functional stop valves are generally used for pressure flow control. Gate valves are used for isolation.
Q:Z41T one 10 gate valve and Z44T one, 10 gate valve difference
Z41T one, 10 is single gate, Z44T one, 10 is double gateAccording to the provisions of the JB/T 308-2004 valve type programming method:Z== gate valve4== connection: flange type1== structure: Rigid single gate4== structure: Rigid double gateT== sealing surface material: copper alloy10== pressure rating: 1.0MPa
Q:What are the advantages and disadvantages of flat gate valves?
The advantage of flat gate valve is that the flow resistance is small, and the flow resistance is similar to the flow resistance of short valve. The flat gate valve with guide hole is installed on the pipeline and can be directly cleaned with the cleaner. As the gate is sliding on the two seat surface, the flat gate valve can be applied to the medium with suspended particles, and the sealing surface of the flat gate valve is actually positioned automatically. The seat seal surface is not subject to thermal deformation of the valve body. Moreover, even if the valve is closed in cold condition, the thermal elongation of the stem will not cause the seal to be subjected to overload. The length of the structure is much shorter than that of the ball valve, and it is easier to start. Light plate gate valve is more refined, but the effect is exactly the same.The disadvantage of flat gate valve is that when the medium pressure is low, the sealing force of the metal sealing surface is insufficient, so as to achieve satisfactory sealing. On the contrary, when the medium pressure is high, if the sealing surface is not lubricated by the system media or foreign media, often opening and closing may cause the sealing surface to wear too much. Another disadvantage is that the circular motion of the circular gate in the circular flow, only when it is at the valve closed position of 50%, this valve is more sensitive to flow control. Moreover, the gate will produce severe vibration when it breaks the high-speed and dense medium flow. The valve seat can also be throttled if the seat is made of a V - shaped opening and is tightly oriented to the gate.
Q:What are the structural differences between parallel and wedge valves?
The structure of globe valve and gate valve. What does this article introduce first?What is parallel gate valve?The sealing cover is parallel to the vertical center line, so the sealing surfaces of the valve body and the gate are parallel to each other. This gate valve is the most common double gate plate, in order to shut down, so that the valve and gate two sealing surface contact closely asked, often used in two ram double sided thrust wedge block. Thus, when the valve is closed, the double side thrust block is contacted with the bottom of the valve body and is gradually stressed.
Q:What is the Z15T-16C letter of the gate valve?
The Z class code indicates the type of gate valve, gate valve is the first letter of the alphabet. The gate is manual driving mode, 1 said the connection form of gate valve for connecting thread, 5 represents the structure form of gate valve for rigid single gate, T gate said lining material of copper alloy, 16 PN1.6MPa nominal pressure valve. C said the valve body material is carbon steel.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range