valve of china 4500

Ref Price:
Loading Port:
China Main Port
Payment Terms:
Min Order Qty:
Supply Capability:

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Quick DetailsStandard or Nonstandard:  Standard Structure:  Gate Pressure:  Medium Pressure
Power:  Manual Material:  Casting Temperature of Media:  Medium Temperature
Media:  Water Port Size:  DN40mm-DN300 Place of Origin:  China (Mainland)
Model Number:  GF4 resilient gate valves:  resilient seat flange

Packaging & DeliveryPackaging Detail: air plastic bag inside/wooden box outside
Delivery Detail: 15-60days

SpecificationsDIN3352 F4 resilient seat flange gate valves
4.certificate:ISO9001 CE

resilient gate valves
3.certificate:ISO9001 CE

available medium:water
working temperature:≤80oC

flange dimensions:DIN2501

face to face dimensions:DIN3202F4.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Valve cover gasket replacement?
Hi Make sure your PVC valve it clear. That puts pressure inside the engine and makes the leaks. If it is plugged just tighten the valve covers might work.
Q:What's the difference between an electric two position control valve and an electric butterfly valve?
Double switch electric butterfly valve, electric butterfly valve is usually said, namely the electric butterfly valve in the electronic case can achieve fully open or fully closed precise place to stop, not directly with the pipeline system flow feedback device for regulating the flow of accurate interaction.
Q:Three eccentric hard sealing butterfly valve, why not fit in the end of the pipe?
The sealing ring will hold up. It does not fit in with the flange end of the pipeline, this addition is the most common and convenient pipeline after purge and easily add pipeline.
Q:The difference between vertical and horizontal butterfly valves in municipal water supply
The general municipal water supply butterfly valve is mainly vertical installation, mainly due to underground pipe network, vertical drive device in the upper, easy to operate, and installation of smaller wells;Horizontal, usually large diameter butterfly valve, usually used in the main network, often open, not easy to collect slag.
Q:Are fire fighting signal valves and signal butterfly valves the same thing?
The same nature: both can open and close, there is also information back fed.Signal valves are collectively referred to as signal butterfly valves.
Q:mitral valve prolapse?
I have Mitral Valve Prolapse, and slight regurgitation. If your cardiologist says not to worry, I wouldn't worry. Mitral Valve prolapse just means you have a slight deformity of the bicuspid valve. It doesn't close correctly. It's not a disease, or anything like that, just a slight deformity. The symptoms are annoying. You may or may not have palpitations, slight sharp chest pain sometimes, dizziness, fatigue, and anxiety from it. You must have it checked yearly to make sure it's not progressing. I have had it since I was born, and now I am 28, and it has not progressed at all. MILLIONS of people are walking around with it, and don't even know it. It's not really a big deal. However, it does have the potential to worsen and you may or may not need a new valve. But that normally happens when you're older, in your 50's or up. Don't worry about it.
Q:Especially butterfly valve
Butterfly valve headstock is a disc shaped disc, in the valve body around its own axis rotation, so as to achieve the opening or closing or adjustment; actuators have electric or pneumatic, and so on, through the transmission device to drive the stem, valve plate rotation;
Q:What is an ERG valve?
Exhaust Gas Recirculation It redirects a portion of the exhaust gasses from the exhaust manifold back into the intake manifold so they can be re-burned. This is part of the emissions system that has been used since the early 70's.
Q:Do you use the straight stem butterfly valve in the fire fighting engineering?
Only the gate valve clearly rod and dark pole, butterfly valve classification is the clamp type and flange type, Zhengzhou butterfly valve factory, Mr. Zhao
Q:Function of signal butterfly valve in fire sprinkler system
The signal butterfly valve is generally installed in two parts: floor level, dry pipe, flow indicator front end, trunk pipe, wet alarm valve, front end.Floor level pipe installation is a function of the signal valve, when the floor spraying system needs repair, close the valve, open the end of the floor drain, emptying the water in the spray system, maintenance; two is the sprinkler system is not allowed inside water, when the butterfly is closed, will transmit a signal to the the fire alarm system, fire alarm system receives a monitoring signal (so called signal butterfly valve), fire sprinkler system that the floor is anhydrous state, fast repair.Wet alarm valve at the front of the signal butterfly valve with the main floor of the main role of the butterfly valve, first, maintenance, and two is the prompt sprinkler system, there is a signal butterfly valve closed, should be repaired as soon as possible.

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range