• Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning System 1
  • Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning System 2
  • Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning System 3
  • Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning System 4
  • Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning System 5
  • Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning System 6
Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning

Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning

Ref Price:
get latest price
Loading Port:
Ningbo
Payment Terms:
TT OR LC
Min Order Qty:
100 pc
Supply Capability:
999999 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing


Steel Linear Slot Diffuser Air Grille

 Supplying Air Diffusers 

-Frame Thickness: 1.0mm /0.8mm
-Any Size be customed 
-Powder Coated RAL 9010/9016


Specification of Air Diffuser


 1

Item

HVAC aluminum air conditioner grille

 2

Materials

Extruded Aluminum alloy (6063-T5)

 3

Blade

Blades in 45°from aluminum profile or as customer’s requirements

 4

Bar spacing

30mm as standard or as customer’s requirements

 5

Materials

0.8mm, 1.0mm, 1.2mm, 1.5mm or according to the customers’ 

 6

Surface Finish

Powder coated, Anodized , PVDF, Mill finish.

 7

Size 

Width x Height, any sizes available

 8

Powder for Finish

Environmental protection and non-toxic, and Color to keep 5 -10 years.

 9

Color

Refer to RAL colors swatch or customized colors available

 10

Design

Drawings designed according to the customers’ requirements

 11

Payment terms

T/T, L/C, PYAPAL, etc.

 12

Delivery time

Usual 15-20 work days for a 40GP container 

 13

Package details

Bubble wrap + Cartons for FCL,  Bubble wrap + Cartons + Wood-box for 

 14

Mesh

Stainless steel security mesh, Aluminum security mesh

 15

Type

Fixing and adjustable installation

Pictures Shown of Air Diffuser

Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning

Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning

Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning

Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning

Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning

Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning

Our service

 

Best quality + Thoughtful service + Reasonable price

Choose CNBM,  PowChooseerful supplier & Best friend   

1. Professional manufacturer of air vent for 7 years.

2. Factory price with high quantity and fast delivery.

3. High grade material and exquisite manufacturing acheives a good quality.

4. Freely sample is available before order.

5.Own anodized factory so diffent finish colour

 

· Adjustable aerofoil-designed blades provide users with the flexiblility to cater to their personal needs. Blades are individually adjustable from the face of the grilles.

· From extruded aluminum of minimum 1.0mm thickness. All grilles are manufactured from highly corrosion resistant heavy gauge aluminum.

· Corners reinforced with welded corner pieces for robust handling during installation. 

· Standard powder coated white finish. Painted finish will be enamel coated and oven baked. 

· Anodised finishes and other finishes are also available upon request.


Company Information

Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning

Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning

Steel Frame Air Grilles Rectangle for Ceiling use Air Conditioning



FAQ:

1, What's size do u have for round type diffuser?

A: We have face size from 150mm to 550mm,neck size from 250mm to 400mm

 

2, Do u still have other types ?

A: Yes, we have round diffuser/ rectangle diffuser/ linear grilles/ baseboard diffusers,etc

 

3, What's the most early delivery time?

A: Within 25 days for each 40'fcl




Q:What are the condensers made of?
Such as solenoid valves, dispensers, dryers, heat collector, fusible plug, pressure controller and other components, they are in order to improve the economy of operation, reliability and safety setting.
Q:Refrigerators do not cool, compressors do not work, but very hot, what is the reason?
For the refrigerator electronic control system, in the case of electricity, with a multimeter measuring AC voltage blocking main control board of the input voltage and the output voltage is normal, the screen to show whether the compressor work? Each sensor is normal or not? The contact normal? If the input voltage and output voltage is normal without the main control board a fault
Q:What is the working principle of the condenser?
Refrigeration principle general refrigerator compressor is the refrigerant by low temperature and low pressure gas compressed into high temperature and high pressure gas after temperature high pressure condenser into the liquid, through the throttle valve throttle valve, is a low temperature low pressure liquid. The liquid medium at low temperature and low pressure is sent into the evaporator to absorb heat and evaporate into low temperature and low pressure steam. It is transported into the compressor again, so as to complete the refrigeration cycle
Q:What is the Basic accessories for air conditioners?
with six system,Air duct system, refrigeration system, humidifying system, electric heating system, power distribution system and control protection system
Q:What is the cause of the overload of the air conditioning compressor?
Dust on the outside condenser can be cleaned, and the heat insulation cotton wrapped on the compressor can be removed
Q:How to deal with the liquid hammer phenomenon of compressor
If the compressor has occurred abnormal impact (knock or impact) sound, and will strongly shake vibration, indicating that the liquid is in the attack. Slight short term abnormal shocks may be of little concern, but often prolonged and heavy fluid shocks cause compressor deformation, rupture, and even breakage, which directly damages the compressor
Q:How many types of drive are there in an air conditioner compressor?
As a traditional refrigeration compressor, reciprocating refrigeration compressor is suitable for the refrigeration system with a wide range of refrigeration
Q:The air-conditioning compressor is stuck. Is there any way to repair it?
When necessary the appropriate starting capacitor capacity compressor for the specifications of a compressor can be normal to try to start up, and can be used with a screwdriver on the reverse way of trying to solve the compressor body.
Q:What is the mean of condenser?
In refrigeration plants, condensers are used to condense the cooling vapours of ammonia and freon. In petrochemical industry, condensers are used to condense hydrocarbons and other chemical vapors. A device in which steam is converted into liquid during distillation. Also called a condenser. All condensers operate by removing heat from the gas or steam.
Q:What are the parts of the outdoor unit?
The outdoor unit comprises a compressor, a heat exchange copper pipe, an expansion valve, a four way valve, a liquid storage tank, an exhaust fan and an electric component

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords