Linear Air Grilles Square Shape for Ceiling use Air Conditioning

Ref Price:
Loading Port:
Ningbo
Payment Terms:
TT OR LC
Min Order Qty:
100 pc
Supply Capability:
999999 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:


Steel Linear Slot Diffuser Air Grille

 Supplying Air Diffusers 

-Frame Thickness: 1.0mm /0.8mm
-Any Size be customed 
-Powder Coated RAL 9010/9016


Specification of Air Diffuser


 1

Item

HVAC aluminum air conditioner grille

 2

Materials

Extruded Aluminum alloy (6063-T5)

 3

Blade

Blades in 45°from aluminum profile or as customer’s requirements

 4

Bar spacing

30mm as standard or as customer’s requirements

 5

Materials

0.8mm, 1.0mm, 1.2mm, 1.5mm or according to the customers’ 

 6

Surface Finish

Powder coated, Anodized , PVDF, Mill finish.

 7

Size 

Width x Height, any sizes available

 8

Powder for Finish

Environmental protection and non-toxic, and Color to keep 5 -10 years.

 9

Color

Refer to RAL colors swatch or customized colors available

 10

Design

Drawings designed according to the customers’ requirements

 11

Payment terms

T/T, L/C, PYAPAL, etc.

 12

Delivery time

Usual 15-20 work days for a 40GP container 

 13

Package details

Bubble wrap + Cartons for FCL,  Bubble wrap + Cartons + Wood-box for 

 14

Mesh

Stainless steel security mesh, Aluminum security mesh

 15

Type

Fixing and adjustable installation

Pictures Shown of Air Diffuser

Linear Air Grilles Square Shape for Ceiling use Air Conditioning


Linear Air Grilles Square Shape for Ceiling use Air Conditioning

Linear Air Grilles Square Shape for Ceiling use Air Conditioning


Linear Air Grilles Square Shape for Ceiling use Air Conditioning

Linear Air Grilles Square Shape for Ceiling use Air Conditioning

Our service

 

Best quality + Thoughtful service + Reasonable price

Choose CNBM,  PowChooseerful supplier & Best friend   

1. Professional manufacturer of air vent for 7 years.

2. Factory price with high quantity and fast delivery.

3. High grade material and exquisite manufacturing acheives a good quality.

4. Freely sample is available before order.

5.Own anodized factory so diffent finish colour

 

· Adjustable aerofoil-designed blades provide users with the flexiblility to cater to their personal needs. Blades are individually adjustable from the face of the grilles.

· From extruded aluminum of minimum 1.0mm thickness. All grilles are manufactured from highly corrosion resistant heavy gauge aluminum.

· Corners reinforced with welded corner pieces for robust handling during installation. 

· Standard powder coated white finish. Painted finish will be enamel coated and oven baked. 

· Anodised finishes and other finishes are also available upon request.


Company Information

Linear Air Grilles Square Shape for Ceiling use Air Conditioning

Linear Air Grilles Square Shape for Ceiling use Air Conditioning

Linear Air Grilles Square Shape for Ceiling use Air Conditioning



FAQ:

1, What's size do u have for round type diffuser?

A: We have face size from 150mm to 550mm,neck size from 250mm to 400mm

 

2, Do u still have other types ?

A: Yes, we have round diffuser/ rectangle diffuser/ linear grilles/ baseboard diffusers,etc

 

3, What's the most early delivery time?

A: Within 25 days for each 40'fcl




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to analyze air conditioning parts?
Their function makes the air around the condenser and evaporator circulate, the indoor air can be circulated, and the indoor and outdoor air exchange can be realized. Electrical control system: all kinds of circuits, such as compressor circuit, temperature control circuit, protection circuit, etc., the components of these circuits and their particular components form the electrical control system of the air conditioner
Q:The air-conditioning compressor is stuck. Is there any way to repair it?
When necessary the appropriate starting capacitor capacity compressor for the specifications of a compressor can be normal to try to start up, and can be used with a screwdriver on the reverse way of trying to solve the compressor body.
Q:What are the technical parameters of the compressor?
Under certain conditions, the gas quality from the suction end to the exhaust end in unit time is called the mass gas content of the compressor under the mine
Q:What are the types of condensers?
The condenser used in boiler, also called flue gas condenser, can effectively save the production cost, reduce the smoke exhaust temperature of boiler and raise the thermal efficiency of boiler. Boiler operation in line with national standards for energy conservation and emission reduction
Q:What are the condensers made of?
Divided into single type refrigeration and heating of type two, regardless of which kinds of form, is composed of a combination of the following
Q:What are the air compressors for?
Wind tunnel experiment, underground passage ventilation, metal smelting
Q:What's the difference between compressor and air compressor?
Both are provided with different medium pressure is compressed. Is a standard atmospheric air through the transformation of the mode of energy output to meet the needs of users of air equipment, energy conversion is generally understood as mechanical energy into kinetic energy
Q:How to repair air conditioning compressor?
The inspection results for the compressor power supply cord is damaged, the compressor terminal generally will rust, if simply replace the compressor wiring card terminals, due to poor contact, and the compressor when working current is large, easy to cause the fire, not a long time or will appear again the same fault, so when replacing the wiring card, must use sandpaper compressor terminal surface rust polished and clean.
Q:What is the function of the air conditioning condenser?
The high pressure and high temperature refrigerant gas discharged from the compressor enters the condenser coil outside the chamber and is cooled by the airflow outside the fan (about 35 degree C) driven by the fan
Q:What are the risk factors of condensers?
A pressure pulse caused by air impact, pressure, or cavitation, causing an explosion of temperature

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range