Mono Block Air Cooled Condensing Unit
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 Sets set
- Supply Capability:
- 10000 Sets per Month 15 days set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
copeland scroll compressor condensing unit(CE certificate)
Our air-cooling condensing unit is prefered by its smart sharp in fields of food storage, meat storage,water chiller,beer brewing, ice maker equipment,mining equipment chiller etc. installation.
professional scroll compressor condensing unit manufacturer of 20 years in China.
reputable after-sales serives.
world brand scroll compressor
high efficient refrigeration capability
good motor
aluminium fin condenser
high quality copper tube
refrigerant:R22.R134a,R404A,R407
capacity:1/6HP--7HP etc.
220V/380V.50/60Hz
- Q:The cooling water pipe has condensed water. Can it be prevented from blowing up with the fan? Why?
- Do not prevent the steam from freezing into water. The fan blows to accelerate the cooling. So it doesn't work
- Q:What is the cause of the resonance in the cooling pipe of the central air conditioner?
- This sound is generally a vibration of the sound, mainly because of the cooling pipe gas, causing the tube qi stagnation occurs, coupled with the water pipe flow increases, it will produce the so-called resonance.The solution: use a vacuum machine to clean the air.
- Q:The cooling water pipe 42 stainless steel tube and 38 stainless steel pipe butt joint, installation field work for about 3 months, found leakage phenomenon, ask which expert how to solve this problem, welding before welding what to improve? How to improve it? What are the main points to be tested after completion of welding, and what specific tests are needed?
- The joint polish and butt if pressure then it is best to use argon arc welding is the best advice with a concentric size reducer with grinder
- Q:What is the cooling water pipe of an automobile engine?Who can explain the introduction of the cooling water pipe of the automobile engine?
- You may say the tank and the engine connecting pipe, the main purpose is to jump by the engine pump water storage cylinder Cao, then recycled to the water tank, water tank by the cooling fan speed, again to the engine, in order to ensure the engine to reach the reasonable temperature, avoid overheating the engine blew up
- Q:Is the water switch for the central air conditioner installed on the cooling water pipe or the cooling water pipe?
- Both water pipes need to be fitted with this water switch.
- Q:Can you tell me how to distinguish the freezing pipes, cooling pipes and condensate pipes in HVAC engineering?
- The chilled water is the water used in the air conditioning. The cooling water pipe is used for the cooling of the unit. The condensation water is caused by the temperature difference.
- Q:The engine cooling pipe is stiff and can not pinch
- The car is old. That's normal
- Q:My car is a 125CC assembly off-road vehicle. The engine is Tanaka's. Can this engine load the oil cooler?By the way, what is the lubrication of this engine?
- Oil cooling is to achieve better lubrication effect but I see in the picture that stuff you said fitted to the exhaust pipe of the exhaust pipe temperature reaches what such a hundred degrees is not baked lubricating oil will be more hot! The lubrication of the engine is to press the oil pump into the oil passage and deliver it to the parts that need lubrication through the oil passage
- Q:How to scale the cooling water pipe of vacuum pump reducer?
- Descaling ultrasonic, high pressure water or chemical reagents, descaling has not used, just know so many methods of descaling, or simply replace the tube to measure the economy of yourself!
- Q:How to decorate the mass concrete cooling water pipe
- Cooling water pipes are not generally advocated! (because partial cooling is not enough after hydration), a temperature hole is set for observation: as long as the temperature difference between the inside and outside of concrete is not more than 25 degrees, no measures should be taken! If the temperature difference is too large, you can take insulation measures (also ensure that the temperature difference is not greater than 25 degrees)This should be the construction team to consider the matter, the design institute will not consider this, are generally handed over to the construction unitThe purpose is to take away the temperature rise of cement hydration in time, and there is no need to do any calculation. According to the water temperature changes during construction, it is good to arrange the water flow
1. Manufacturer Overview |
|
---|---|
Location | Shandong,China |
Year Established | 2002 |
Annual Output Value | US$1 Million - US$2.5 Million |
Main Markets | 8.33% North America 8.33% South America 8.33% Eastern Europe 8.33% Southeast Asia 8.33% Africa 8.33% Oceania 8.33% Mid East 8.33% Eastern Asia 8.33% Western Europe 8.33% Central America 8.33% Northern Europe 8.33% Southern Europe |
Company Certifications | ISO 9001:2000;RoHS;CE |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Qingdao,shanghai,Ningbo |
Export Percentage | 41% - 50% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English |
b)Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | 6 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | High and/or Average |
Send your message to us
Mono Block Air Cooled Condensing Unit
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 Sets set
- Supply Capability:
- 10000 Sets per Month 15 days set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords