Rubber Foam Heat Insulation Tube
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 20 Cubic Meters m³
- Supply Capability:
- 200000 Cubic Meters per Year m³/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Detailed Product Description
1.air conditioning ,industrial cooling etc pipe;
2.low conductivity factor;
3.Self extinguishing,
4.air conditioner duct tube
1.Product features:
It is an elastomeric rubber based insulation material in the form of sheet and pipe with closed cell structure which doesn’t contain CFC halogen materials (chlorine, bromine, etc.) and PVC. It is manufactured to be used for air conditioning, heating and cooling systems.It has high thermal insulation value. It can be faced with aluminium foil and can be self-adhesive.
2. Application:
It is a black coloured elastomeric rubber based insulation material in the form of sheet and pipe with closed cell structure It is used on the exterior surfaces of the ducts and large diameter pipe lines in the heating, cooling and air conditioning systems for thermal insulation and condensation control purposes. It is developed to use at battleships, merchant ships, transportation systems; in areas where there are crowds of people such as business and entertainment places, hospitals, airports in order to reduce the emissions of smoke and poisonous gases. The sheets are adhered to the duct surface by using a special adhesive that it suggested. For the pipe applications, the pipe to be insulated and the rubber surface should fit properly and no gap should be left in between. Joints should be tightly sealed and they should be covered with insulation tape afterwards if necessary. Taping should not result in thickness loss. The application should be protected against distruption and rupture.
- Q: How to decorate the mass concrete cooling water pipe
- Cooling water pipes are not generally advocated! (because partial cooling is not enough after hydration), a temperature hole is set for observation: as long as the temperature difference between the inside and outside of concrete is not more than 25 degrees, no measures should be taken! If the temperature difference is too large, you can take insulation measures (also ensure that the temperature difference is not greater than 25 degrees)
- Q: Volkswagen Sagitar cooling pipe, three pass joint, what is the name of
- Hello This fitting is called a three - way connector. It is better to change aluminum because of the bad three - way connection. This is a common problem for volkswagen. After replacing the aluminum three pass, it can prevent future damage again.
- Q: The cooling water pipe 42 stainless steel tube and 38 stainless steel pipe butt joint, installation field work for about 3 months, found leakage phenomenon, ask which expert how to solve this problem, welding before welding what to improve? How to improve it? What are the main points to be tested after completion of welding, and what specific tests are needed?
- The joint polish and butt if pressure then it is best to use argon arc welding is the best advice with a concentric size reducer with grinder
- Q: Is the cooling tube facing the light pressed E or E continuously?
- Light up, press E, press E if you press it all the time, it doesn't respond
- Q: The cooling water pipe has condensed water. Can it be prevented from blowing up with the fan? Why?
- The condensate on the cooling pipe is blown with a blower, and the condensate can not be prevented from producing.First of all, you should find out why condensed water is produced on the condensate pipe. Because the water in the condensate pipe is lower than the ambient temperature, the water vapor in the air can condense into the condensate pipe (where the temperature is low and the water vapor condenses there). This is the reason for the condensation of water droplets from the water pipes at home before the summer rains. If you don't want the water vapor to condense in the condensate pipe, take the following two methods:I. the surface temperature of the condensate pipe is higher than the ambient temperature;Two. Let the condensate pipe through the environment space and the outside to maintain good ventilation conditions, if ventilation is not smooth, at this time can use fan forced drainage cycle, as much as possible the indoor water vapor excluded.If you use a fan in a confined space, you can't blow it. When the water reaches a saturated vapor pressure, it condenses into water, no matter what object it attaches to. Otherwise it does not conform to the laws of physics.
- Q: Rifled or smoothbore gun is? Why does it only use water cooling pipes, while anti-aircraft guns, infantry fighting vehicles and artillery guns do not? Thanks a lot!
- Of course is the rifled gun, the gun is designed crash before the mid nineteenth Century. At present, only emphasizes the smoothbore high velocity direct tank gun of this demand, not the other needs, and in order to ensure the accuracy of long-range shooting only with rifled gun. There is enough space for warships. If there is a need for firing speed, water cooling systems can be used, and anti-aircraft guns and infantry fighting vehicles are not likely to be water-cooled in size and quality.
- Q: What is the cause of the resonance in the cooling pipe of the central air conditioner?
- General central air conditioning with electromagnetic expansion valve, depending on the sound, where the resonance, and see if the throttle valve is sound. If the effect is very good, you can consider the fixed vibration parts, and if the effect is not good, we should consider whether the pipeline appears to throttle, bend the place is whether the copper tube deflated. This problem is troublesome.
- Q: The engine cooling pipe is stiff and can not pinch
- The car is old. That's normal
- Q: Can you tell me how to distinguish the freezing pipes, cooling pipes and condensate pipes in HVAC engineering?
- The chilled water is supplied at the end of the fan coil and the temperature is 7-18 degrees. The exterior is usually insulated with rubber and plastic;The cooling water is supplied to the refrigerator and is used without heat. The exterior is painted with green industrial paint;The condensed water pipe is generally installed at the lower part of the fan coil, and is connected with the water receiving plate, and introduces a floor drain or a collecting device without cold protection and brushing.
- Q: Work on the coolant at work today the cooling pipe slid open spray clothes in some parts of the water, I just put clothes in front of the apple 5S mobile phone bag. The uncertain parts into the mobile phone bag clothes there is no spray to worry. Pocket inside the mobile phone will be sprayed into the water, how to identify, does it matter?
- Can open to see the battery, there is a red place, then the water.
1. Manufacturer Overview
Location | Shandong,China |
Year Established | 2009 |
Annual Output Value | |
Main Markets | 30.00% Mid East 10.00% Southeast Asia 10.00% South America 9.00% Oceania 9.00% North America 8.00% South Asia 6.00% Eastern Asia 5.00% Western Europe 5.00% Eastern Europe 3.00% Northern Europe 2.00% Central America 2.00% Africa 1.00% Southern Europe |
Company Certifications | ISO 14001:2004;IQNET |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Qingdao,Ningbo |
Export Percentage | 51% - 60% |
No.of Employees in Trade Department | 15 Day(s) |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Rubber Foam Heat Insulation Tube
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 20 Cubic Meters m³
- Supply Capability:
- 200000 Cubic Meters per Year m³/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords