Perfect Power Output Section
The HIVERT general MV VFD adopts the power cells connected in series and voltage overlapping method (i.e. Power cells multi-level cascade technology), it can output the perfect PWM sinusoidal waveform (see Figure 2 and Figure 3). It has the following advantages:
1. No need for the additional output filter
2. Directly driving general synchronous or asynchronous motor
3. No de-rating operation on the motor
4. No dV/dt stress on the insulation of motor and cables
5. No torque ripple, extending service life of motors and mechanism
6. No cable length restriction within the acceptable voltage drop.
The general MV VFD has the following protection functions and features:
Overload and over-current
Phase loss and grounding
Over voltage
Overheat
Current limit
Redundant control power supply
Cell Bypass (optional)
Cabinet door alarm
Phase-Lock function
Synchronous Switching between VFD and Grid system
Soft start of motor
High efficiency >98% (VFD at full-load)
Electrical Isolation by the optic fiber
Built-in PID regulator
RS485 communication with the protocol, Modbus as standard, optional Profibus-DP, Ethernet,etc
Accurate fault records, easy to check fault history
Compact structure and layout, customized design is available
- Q: What is the number of parameters of the motor frequency of the Siemens inverter?
- Siemens inverter motor pole number parameter code is r0313 motor pole pairs. Note that the number of pole pairs.
- Q: Is it possible to use a different laptop's power adapter?
- See the adapter is suitable for notebook models to use, the following three conditions for reference: 1. The output voltage of the adapter is the same as that of the notebook. 2. Is the adapter's output current consistent with the notebook's requirements? (Or a little bit of the current is also not.) 3. The size of the joint is appropriate. (If the connector is too loose, will be bad, excessive fever.) For DELL and HP / Compaq and other notebook power adapter, will involve a decoding problem. Please pay attention when the pro to buy. It is said that the market is also very popular universal adapter, a friend bought a LVSUN brand universal adapter LS-PAB90-BC10, with eight joints. Adapter has a liquid crystal display, you can automatically switch the voltage, very smart, with more than a year, has also been used
- Q: Three-phase asynchronous AC motor speed control method
- Third, cascade speed control method Cascade speed regulation refers to the winding motor in the rotor loop into the adjustable additional potential to change the motor slip, to speed control purposes. Most of the slip power is absorbed by the additional potential in series, and the additional device is used to return the absorbed slip power to the grid or to convert the energy. According to the slip power absorption and utilization, cascade speed can be divided into motor cascade speed, mechanical cascade speed control and thyristor cascade speed form, the use of thyristor cascade speed, which features: Can be transferred in the speed of the process of slip loss back to the grid or production machinery, the higher efficiency; Device capacity and speed range is proportional to the investment province, for the speed range of 70% -90% of the rated speed of production machinery; Speed ??control device failure can switch to full speed operation, to avoid shutdown; Thyristor cascade speed power factor is low, the greater the impact of harmonics. This method is suitable for use in wind turbines, water pumps and rolling mills, mine hoists, extruders.
- Q: I have a 5.5 kilowatts of 4-pole motor, want to pass through the inverter, slow down to 130 per minute use, eliminating the need for speed,
- wo recommendations, the first, the use of vector control of the inverter, you are expected to run the frequency of about 5Hz, this time, ordinary V / F inverter output torque may be small, not necessarily meet the requirements, of course, if it is High-end imported inverter, the problem should be small, with the domestic vector inverter, the frequency can also be full torque output;
- Q: Servo control system can give the inverter signal,
- Servo motor driver can give the inverter signal, with analog output to control,
- Q: Yasukawa inverter reported bb code that is the reason why the base blockade?
- This should be the meaning of the drive block, that is, the drive signal is locked, there is no drive signal, and start a frequency change but no voltage output, you find someone to repair the circuit board can be used normally, this is generally the circuit board Problem, the module is less likely to be bad
- Q: ASUS and dell notebook power adapter can be universal?
- I can not remember to insert into the ah. The Looks like DELL that interface is very special
- Q: What is the difference between AC and DC frequency converters?
- L inverter air conditioner refrigeration system components: inverter air conditioner by the compressor, evaporator, condenser, electromagnetic four-way valve, electronic expansion valve, defrost valve, double capillary and other components (see Figure II), work, air conditioner Room needs, automatic control of the inverter output frequency higher AC, the motor speed to speed up, the compressor cooling capacity increased to achieve the purpose of rapid cooling or heating, on the contrary, when the room cooling or heating less, Compressor to normal speed or lower speed operation, therefore, inverter air conditioner has a continuous cooling capacity adjustment, making the room temperature fluctuations smaller. In the process of compressor operation, the microcomputer system controls the inverter compressor at the same time, controls the opening degree of the electronic expansion valve, maintains the proper refrigerant flow, and directly changes the flow of the refrigerant in the evaporator to change its state, the compressor The speed corresponds to the opening degree of the expansion valve, and the displacement of the compressor corresponds to the supply amount of the expansion valve, so that the degree of superheat is not so large that the capacity of the evaporator is maximized, so that the refrigeration system The most efficient control.
- Q: Does the inverter set the number of poles to match the number of poles of the motor?
- Variable-frequency (VFD) is the application of frequency conversion technology and microelectronics technology, by changing the motor operating frequency mode to control the AC motor power control equipment. The inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit and so on.
- Q: 400w 6-pole motor should be equipped with much of the inverter?
- Under normal circumstances, the market are sold on the inverter are based on the common 4-pole motor matching, when to match the 6-pole motor, the inverter to a large power level, which is 400W of the first-class power 0.75KW, and so on