• High Medium Voltage Drive 10KV 4600KW RMVC4000-A100/5800 VFD System 1
  • High Medium Voltage Drive 10KV 4600KW RMVC4000-A100/5800 VFD System 2
High Medium Voltage Drive 10KV 4600KW RMVC4000-A100/5800 VFD

High Medium Voltage Drive 10KV 4600KW RMVC4000-A100/5800 VFD

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
100000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Energy-saving Solutions for Enterprise
1
Program Overview
Saving energy achieves 10% -70%
The enterprises do not need to pay for expense of equipment manufacture and installation.
Enterprises only need to pay the saving electricity expense to our company according to the actual quantity of energy saving after the equipments put into operation.
According thousands of the projects’ implementation experiences, such projects recover the investments in three or four years. (Equipment service life is 15 years)
Our company will no longer charge the saving electricity expense after recovering the investment.

The significance of the program:
1
)、Concentrate on solving problems of energy conservation, make enterprises’ energy-saving work reach new level and take their social responsibility
2
)、Avoid the enterprises reactive power fine of low power factor caused by electric energy using (according to Ministry of Electric Power and Water Resources, State Price Control Bureau establish the " measures of power factor adjustment expense ").
3
)、Avoid the high-energy consumption enterprises are implemented differential prices because of the changes of national power regulation.
4
)、For the standard-conforming large-scale (saved energy equal 10 thousand tons standard coal or more) energy-saving technological transformation projects, China will reward the enterprises for energy saving which based on the "Financial Incentives Interim Measure for Energy-saving Technological Transformations" established by Ministry of Finance, the National Development and Reform Commission.( Amount of 200 yuan / ton of standard coal).
5
)、Equipments recovery period is generally 3-4 years, each period payment equal to the amount of current energy-saving benefits, and equipments service life are 15 years, so enterprises will gain huge energy-saving benefits.


2
Implementation Process
Energy Audit
Energy Saving Program Design
Construction Design
Equipments Manufacture
Construction and installation
Maintenance and Repair
Energy Monitoring and Efficiency Insurance
Recovery of Program Investment


3
Program Features
High energy-saving efficiency
The project saving rate is generally 10% -30%, highest is up to 70%.
Clients Zero Investment
All works of design, audit, manufacturing, construction, monitoring are handled by RXPE, clients does not require investment.
Energy-saving Guarantee
RXPE promises the amount of energy saving, ensuring that clients’ cost reduction immediately.
Short Investment Recovery Period
The investment recovery period is short, average period is 3-4 years.
Low Risk
Customers do not input large sums of money also can enjoy professional energy-saving products, technologies and services, and the investment risk is very low.
Improvement of Cash Flow
Customers with the support of RXPE approve energy-saving program to improve cash flow, invest the limited funds into other priority investment areas.
Enhance competitiveness through implementing energy conservation, improving energy-saving efficiency, reducing energy costs and enhancing the quality of environment, establish green corporate image and enhance market competiveness.

Q: In the case of the inverter, why can not the normal operation after removing the gearbox? The motor is 4 pole.
If there is a load, it may be less than the torque. So it can not run.
Q: What is the common COM point of the PLC and the inverter? Is it positive?
Plc is divided into two kinds of transistor output and relay output, com side may be connected to the high level may also be connected to the low level, the general input com port then low, the output port com mouth high, specifically what to take See the data sheet. Inverter is the same, the inverter has 24v com side and 10v com side, can not be connected together, com side generally low.
Q: How does the spindle drive system of the inverter realize the positive and negative control of the main pole?
The general inverter has an external terminal control and communication control two modes optional, select one of them can be completed ah
Q: What is the application of variable frequency speed control?
In the second half of the 20th century, the power electronic devices from the SCR (thyristor), GTO (gate can be turned off thyristor), BJT (bipolar power transistor), MOSFET (metal oxide field effect transistor), SIT (electrostatic induction transistor ), SIT (Electrostatic Inductive Thyristor), MGT (MOS Control Transistor), MCT (MOS Control Gate) to today's IGBT (Insulated Gate Bipolar Transistor), HVIGBT (High Voltage Insulated Gate Bipolar Thyristor), Device To promote the continuous development of power conversion technology. Since the 1970s, pulse width modulation variable frequency (PWM-VVVF) speed control research has aroused people's attention. In the 1980s, the PWM model optimization problem, which was the core of the frequency conversion technology, attracted people's interest and made many optimization modes, in which the saddle-wave PWM mode was the best. The 20th century, the late half of the 1980s, the United States, Japan, Germany, Britain and other developed countries VVVF inverter has been put into the market and widely used.
Q: Laptop power adapter (no power supply, but indicator light)
Notebook power adapter can not charge, but the indicator light does not light the common reasons are: 1, the power adapter is broken or the connector is broken. 2, the power adapter output problem, no output or output is too low, can not give the computer charge. 3, the notebook charging interface is broken, not into the electricity charge. 4, the notebook power management circuit out of the fault, resulting in can not charge.
Q: Variable frequency pump pressure in the very low flow instability, why?
. If you want to stabilize the pressure, you must adjust the pipeline characteristic curve is the work point to enhance, so that you can both stabilize the pressure and adjust the flow.
Q: Huichuan frequency converter drag a 4-kilowatt four-pole motor to change the six pole can?
can. Re-enter the new motor parameters in the drive.Inverter motor power to 4KW, speed 980 can!
Q: How does the variable frequency motor output torque at very low frequencies?
Low frequency, the motor torque is relatively low, generally VF inverter performance is good or bad, the price level reflected in this time. But there is torque to enhance the function, it will not move without moving. If no load can not start, check the motor card and other mechanical problems such as whether there is a problem.
Q: Can the inverter be used to control the speed of the DC motor?
The inverter can be used to control the speed of the DC motor. Inverter control DC motor is to control the DC motor. Inverter is the application of frequency conversion technology and microelectronics technology to change the AC power frequency and effective voltage power control equipment. The frequency converter is usually used to control the AC motor. Inverter at work can change the AC power frequency and effective voltage, another point of view, is the inverter in the control output (injected into the controlled device) AC frequency, but also control the output of the effective power. A DC motor is a rotating electric machine that converts DC power into mechanical energy. DC motor coil in the current must be in accordance with certain changes (commutation) can be rotated, according to the principle of commutation DC motor can be divided into brush and brushless motor two categories.
Q: The inverter flat rate transferred to 29, on the submersible pump to burn the coil ?!
4, high-speed motor: high-speed motor running process will produce a large number of harmonics, enhance the output current of the inverter, resulting in a lot of heat. Therefore, the inverter selection is also larger than the ordinary one gear. 5, explosion-proof motor: In some mines, oil extraction environment, the frequency conversion system is explosion-proof motor, the choice of inverter should use the explosion-proof function of the inverter, and the inverter placed in a safer place. 6, the degree of protection: for dust, wet applications, inverter selection should pay attention to its protection level. Or choose Ampang letter AMB inverter, the fan can also run in the water. 7, single-phase motor: When the scene using single-phase motor, the inverter useless. 8, variable pole motor: When the field using variable pole motor, the inverter selection should ensure that the maximum operating current should not exceed the rated current of the inverter

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords