Gel Technology Battery Ares(OPzV) Series 6OPzV 300

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 unit
Supply Capability:
5000000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:


Gel Technology Battery Ares(OPzV) Series Introduction

Ares(OPzV) range battery adopts traditional gel technology .
The products are designed as standby power for communication, power, military and broadcast and television system with excellent deep cycle performance. The design float life is 18+ at 77oF(25oC)
The Ares(OPzV) range batteries are ensured the quality with NARADA's QA system according to the ISO9001 and ISO14001 standard.

 

Gel Technology Battery Ares(OPzV) Series 6OPzV 300

Gel Technology Battery Ares(OPzV) Series 6OPzV 300

Gel Technology Battery Ares(OPzV) Series 6OPzV 300

 

Type:

  6OPzV 300

Voltage:

  2V

Nominal Capacity:

  300Ah(C10)  300Ah(10 hours rate:)

Length:

  145mm

Width:

  206mm

Height:

  356mm

Height   with termial:

  389mm

Weight:

  28Kg

Gel Technology Battery Ares(OPzV) Series Technical Feature:

  • Traditional gel technology

  • 18+ years design life under floating application   and cycle life is above 1200 at 80% DOD   under temperature 25 oC.

  • Reliable seal performance, no acid spillage, recombination efficiency reach 99.9%

  • Initial capacity above 100%, the remaining capacity above 94% after storage for 3 months (25oC)

  • low float charge voltage. design (2.23V/cell, 25oC), extremely consistent float charge voltage
     Flexible connectors and convenient installation

Gel Technology Battery Ares(OPzV) Series Compliant Standards :

  • IEC60896-21/22

  • Din standard

  • UL

  • Manufactured under system ISO9001(TUV) and ISO14001(DNV) by Narada

Gel Technology Battery Ares(OPzV) Series Battery Installation Compliant with:

  • EN 50272-2 or local equivalents

Gel Technology Battery Ares(OPzV) Series Main Application:

  • Telecommunications

  • Motive power applications

  • Railway and mining markets

  • Uninterruptible power supply (UPS)

  • Solar energy storage application

  • Other applications to provide integrated stored energy system

Gel Technology Battery Ares(OPzV) Series Products Characteristics:

  • Recommended float charge voltage for 2V battery: 2.23Vpc at 25oC(77oF)

  • Self discharge rate :< 2% per month  at 25oC(77oF)

  • Design life: 18+ years at 25oC(77oF)

  • Shelf life: 6 months at 25oC(77oF)

  • Valve regulated system, no water addition needed

FAQ


What is sulfation of batteries?

Sulfation is the formation or deposit of lead sulfate on the surface and in the pores of the active material of the batteries' lead plates. If the sulfation becomes excessive and forms large crystals on the plates, the battery will not operate efficiently and may not work at all. Common causes of battery sulfation are standing a long time in a discharged condition, operating at excessive temperatures, and prolonged under or over charging.

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

Do batteries self-discharge when not in use?

All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the hazards of battery over discharge?
Excessive discharge can seriously damage the battery's electrical performance and cycle life.
Q:How should the battery be well maintained?
Battery Pile The battery pile head is part of the battery connected to the vehicle. If the corrosion or poor connection occurs, the battery will work poorly. The owner can check whether there is a white powder near the pile head, which is the sign of the pile head corrosion. If the white powder is more, you can use boiling water to burn it off, and then its anti-corrosion treatment, in the pile head smear some grease or preservatives can, but should not be too much to apply, so as not to affect the use.
Q:What is the difference between a maintenance-free battery and a conventional battery?
Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
Q:How to repair the battery?
To the battery in accordance with the 0.1C current discharge, record the discharge time. Its discharge current multiplied by the number of hours of time, is the battery repair capacity. If the Chongqing battery capacity to reach the nominal capacity of more than 70%, the end of the repair.
Q:The role of the battery?
Battery is widely used, can be used for ups, electric cars, scooters, cars, wind energy solar systems, security, and so on.
Q:How does the battery increase the voltage?
The so-called battery is the storage of chemical energy, if necessary, the release of electrical energy of an electrical chemical equipment.
Q:What are the advantages of maintenance-free batteries?
Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
Q:What is a maintenanceable battery?
It also has a shock, high temperature, small size, self-discharge characteristics. Life is generally twice the ordinary battery.
Q:Lead-acid battery how to maintain?
After passing the test, cover the exhaust cutting, pay attention to restore the filler, cover the battery cover, if the cover is glued, then glue bonding.
Q:Maintenance-free battery how to detect it?
Battery pole Pole terminal has corrosive material without treatment, as long as no loose on it. If the appearance of the corrosive material, the inner surface of the terminal will also be corrosion, resulting in increased resistance, affecting the normal battery charging and discharge, it must be promptly processed.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range