Technical specifications

Table 2.3: Technical Parameters of QD200 Series Frequency Inverters

ITEM

SPECIFICATIONS

Main

Input

Rated voltage and frequency

Single-phase 200V class:  200V-240V,50Hz/60Hz

3-phase 400V class:  380V-480V , 50Hz/60Hz

Allowable value of change

Voltage: 380V-15% ~ 480V+10%;  Frequency: ±15%

Main output

Output voltage

Maximum output voltage equals to input voltage

Output frequency

0.5 Hz to 400 Hz

Overload capacity

150% of rated output current for 60s, 200% of rated output current for 2s

Control performance

Modulation mode

3-phase PWM, 2-phase PWM

Control mode

V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving

Setting method of run command

Outer terminal, keyboard panel or serial communication

Setting method of speed command

Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal

Speed setting resolution

Keyboard: 0.1 Hz

Analog setting: 0.05/50Hz (10bit)

Speed control precision

V/f control:±2%

vector control without PG (open loop control): ±0.2%

Speed control range

V/f control 1:40

vector control without PG (open loop control)  1:200

Acceleration and Deceleration

Time

0-3200.0s

switching frequency

1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency

Analog input

Number

2 ways: AI1、AI2

Type

DC voltage or DC current

Maximum input range

AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable

AI2: 0 to 10VDC or PTC probe input receivable

Analog output

Number

1 way: AO1

Type

DC voltage or DC current

Maximum input range

Voltage output: 0 to 10V, Current output: 0/4 to 20mA

logic input

Number

0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2

15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2

note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic)

Type

Source or Sink

Maximum input range

0-24VDC

ITEM

SPECIFICATIONS

logic output

Number

0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C

15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C

pulse signal output

OC,output frequencycurrentoutput、ect other function

relay output

RA-RB-RC, including a NO contact and a NC contact

Maximum switch capacity:

T1A,T1B: 3A at 250VAC, or 4A at 30VDC

T2A,T2B: 2A at 250VAC or 30VDC

Serial communication interface

RS485 interface supports Modbus protocol.

Display

4-digit LED digital display

For display of frequency setting, output frequency, fault code and parameter setting etc.

Environment

Standard

Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.

Altitude

Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m)

Ambient environment

0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating.

Storage: -25 ~ 70°C

Humidity

No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3

Impact strength

15gn for continuous 11ms, In accordance with IEC/EN60068-2-27

Maximum antipollution capacity

Class 2, in accordance with IEC/EN61800-5-1

Structure

Protection level

Top: IP41 (without removing the protective top cover). Other parts: IP20

Cooling Method

Forced Air cooling

Installation method

Wall mounted

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:My motor is a low frequency 8 pole motor, about 80W. I would like to choose a frequency converter
VACON frequency converter (Finland wholly owned) Model: NXL 0006 2 C1N1 Parameters: Low overload Continuous current: 6.6A 110% Overload current: 7.2A 110% Overload power: 1.5kw (ambient 40 ℃) High Overload Continuous Current: 4.8A 150% Overload Current: 7.2A 150% Overload Power: 1.1kw (Ambient 50 ℃) Maximum current: 9.6A Weight: 2.0kg Mechanical specifications: 84 x 220 x 172 Please consult the pre-sale technical support department
Q:What is the laptop adapter
2, the basic composition: input line + charger main body + output line + connector such as Acharger single-band notebook charger composition, which constitute the basic elements of the notebook charger, as inside the internal parts is very complicated.
Q:What is the working principle of high voltage electrodes and frequency converters?
High-voltage inverter is the input power supply voltage above 3KV high-power inverter, the main voltage levels are 3000V, 3300V, 6000V, 6600V, 10000V and other voltage levels of high-voltage high-power inverter High voltage inverter from high - low - high; low - high; high - high points.
Q:Can the laptop power adapter be generic?
Not common. Different computer adapter interface is not the same, and the voltage, current is not the same. If just the same, you can use, the voltage can also be used.
Q:Three-phase motor, quadrupole asynchronous motor to 15rpm, the inverter output how many volt voltage? The 4 V
The voltage does not change, but the frequency changes, about 0.5 Hz
Q:What are the types of power adapter used in notebooks?
The regulator wants the laptop adapter to not waste energy or add harmonics to the electricity lines. The first factor is that the adapter should plug the plug without any load, and it should be as small as possible to absorb power (standby). People are accustomed to the laptop adapter inserted in the socket, but not connected to the computer, the request can prevent the loss of this situation. The second factor is the recent requirement that it requires a specific average power efficiency at different load conditions (25%, 50%, 75%, and 100%) and is implemented by the global regulatory agencies in order to facilitate compliance with the specification And reduce overhead costs. Finally, the European and Japanese mandated reduction harmonics requirements have been applied to laptop power adapters because they have exceeded these standard specifications for the 75 W input power threshold. In a sense, the mobile / universal features of the laptop adapter make it the first mass production power product subject to the IEC1000-3-2 specification.
Q:Can the notebook's power adapter be mixed?
At present, the market sales of notebook power is generally 90 watts and 65 watts two, using integrated graphics, or configure the low-end notebook, usually 65 watts. Using the independence was, the configuration of high-end, or the game audio and video of this, are generally 90 watts. If the laptop's power adapter is damaged can not be used, it is best to repair the department as soon as possible to repair. If it is for emergency, before using the two adapters to check the output power and current and voltage are conceded, as the adapter input current and voltage is not the same, should be the general household voltage is 220V, so almost all of the notebook power The adapter is 100-240V ~ 1.5A words, as long as the output current and voltage values, and wattage equal, and then one is the same interface, you can mix. In general, the voltage is stable, the output wattage is the same, the notebook is basically no harm.
Q:What is the number of parameters of the motor frequency of the Siemens inverter?
It is best to provide the model of the inverter Oh!
Q:What is the frequency converter used to do, why some motor with the inverter?
Speed control, there are speed requirements of the place are in the inverter
Q:Jd1a-40 motor speed controller and how to connect the motor
Third, cascade speed control method Cascade speed regulation refers to the winding motor in the rotor circuit in the adjustable additional potential to change the motor slip, to achieve the goal of speed. Most of the slip power is absorbed by the additional potential in series, and then an additional installation occurs, and the absorbed slip power is returned to the grid or converted to the energy. According to the slip power absorption application method, the cascade speed regulation can be divided into the motor cascade speed regulation, the mechanical cascade speed regulation and the thyristor cascade speed regulation situation, take the thyristor cascade speed regulation, Suitable for fans, pumps and rolling mills, mine hoists, extruders on the use. Fourth, winding motor rotor series resistance speed control method Fifth, the electromagnetic speed control motor speed method Six, hydraulic coupler speed control method This method is suitable for fan, pump speed.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range