• Butterfly Valve Without Pin Ductile Iron DN510 System 1
Butterfly Valve Without Pin Ductile Iron DN510

Butterfly Valve Without Pin Ductile Iron DN510

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
5 set
Supply Capability:
50000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Centerline structure,pinless double half shaft design.
Disc has two-way bearing, no installation direction requirements.
Non-backed replaceable seat with good performance and a longer working life.
Square and short neck for lable use and cost saving.
Easy installation, no need flange gasket.

 

SizeDN50mm-DN600mm
Design standardAPI609/EN593
End flangeDINPN10/PN16, BS4504PN10/PN16, ANSI class125#/class150#
Face to faceAPI609/EN558-1
Top flangeISO5211
BodyDuctile iron/Cast iron
DiscDuctile iron/CF8/CF8M/C95400/C95500
StemSS420
SeatEPDM/NBR/Viton/PTFE
ActuatorBare shaft/Lever/Gearbox and handwheel
CoatingEpoxy/Nylon/PTFE
PinWith out pin
Suitable mediumWater/Seawater/Sewage/Air/Foodstuff/Oil

 

 

Q:Is the axial force and torque of the wedge gate valve the same?
The sealing performance is good, the gate valve is not easy to be jammed when heated, and is suitable for the parts with frequent switches. B is suitable for steam, high temperature oil and gas medium. C is not suitable for easy coking medium.
Q:Gate valve Z41H-16Q generally used for what place?
Commonly used in petroleum, chemical systems, especially in long-distance pipelines of petroleum and natural gas.
Q:what are their applicable conditions? Advantages and disadvantages?
The gate valve is one of the simplest valves. Generally manual, most of the electric valve failure, as a manual. Butterfly valve is more, I saw the pneumatic butterfly valve, that is, with gas control closed, general and solenoid valve matching.Without strict conditions and advantages and disadvantages, of course, the equipment requires a relatively high degree of automatic control. I can check it out on Baidu.
Q:What's the difference between the knife gate valve and the stop valve?
Standard light valve professionals to answer for you, gate valve refers to the closure of parts (gate) along the central line of the vertical direction of moving valve. The gate valve is mainly used for cutting in the pipeline. The valve is a valve with a very wide, cutting device general caliber DN = 50mm use it, sometimes a small diameter cutting device also use valve, gate valve has the following advantages:Fluid resistance is small.
Q:Why does the fire hydrant box in the air defense area need to be added with gate valves?
Code for design of basement for civil air defence GB50038The installation and installation of the protective valve on the water supply line of the 6.2.13 air defense basement shall comply with the following requirements:OneWhen the water supply pipe from the entrance into, should be set up in the inner protective sealing door;
Q:What is the allowable leakage rate of the gate valve D?
In GB/T 13927, the leakage rate of the valve is divided into 10 grades, namely: A, AA, B, C, CC, D, E, EE, F, G class. And stipulates that when the order contract does not specify, the metal sealing valve according to D requirements.
Q:What are the features and uses of the gate valve?
1) advantages: sealing performance than the cut-off valve, the fluid resistance is small, open and close more effort, full sealing surface by the erosion of media, media flows from the restrictions, with double flow, small structure length, wide application range. 2) disadvantages: high size, open need a certain space, opening and closing time is long, in the opening and closing, the sealing surface is easy to erode and scratch, and the two sealing pairs bring difficulties to the processing and maintenance.3) use: gate valve is generally used in the caliber of DN15-1800mm pipes and equipment, and its dosage is great, mainly cutting off function, not allowed to throttle.
Q:What kind of valve is gate valve? Is it different from the cut-off valve?
Gate valve and the role of the cut-off valve, are playing a role in isolation. The difference is that the gate valve and the cut-off valve are constructed differently. Fluid from the gate valve flow and flow direction is straight, there is no change in direction, but in the cut-off valve is from the bottom of the valve flow into the flow from the upper part of the spool.
Q:Is the gate valve clockwise or closed?
In general, the valve is clockwise turn off, in the case of special requirements under the opening.
Q:What type of flange does it fit with the gate valve?
According to the welding plate flange, flange material selection of piping material.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords