• Aerial Bundle Cable  Power-Transmitting And Strong Mechanical System 1
  • Aerial Bundle Cable  Power-Transmitting And Strong Mechanical System 2
Aerial Bundle Cable  Power-Transmitting And Strong Mechanical

Aerial Bundle Cable Power-Transmitting And Strong Mechanical

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 Product Introduction:
Aerial Bundle Cable  power-transmitting and strong mechanical。

 

Operating Characteristics:
(ABC Cable) has characters of power-transmitting and strong mechanical. In comparison with bare wire, aerial insulated cable boasts many advantages, such as:small span in laying, higher safe reliability, better atmosphere aging resistence property. Aerial Bundle cable(ABC Cable) has the priority to be used in urban and rural power-transmitting construction project.

 

Specification:

 1kV Aerial Bundle cable(ABC Cable)

 Standard:IEC502、IEC227   
 
Conductor:aluminium , steel-Al
 
Insulation Materials: XLPE, HDPE
 
Working Temperature : 0℃-90℃;
 
Minimum Bending Radius:
Overall diameter<25mm:4×overall diameter;
Overall diameter≥25mm: 6×overall diameter.
 


Cross Section mm²

Ref. diameter
mm

Kg/km

Commom

Light

XLPE

 HDPE

XLPE

HDPE

Commom

Light

185/30

26.4

23.4

1003

1005

926

928

240/30

28.6

25.6

1251

1254

1169

1171

300/40

31.8

28.8

1524

1527

1433

1435

 

Aerial Bundle Cable  Power-Transmitting And Strong Mechanical

Aerial Bundle Cable  Power-Transmitting And Strong Mechanical

 

Q: Hi,I have a set of Sony speakers that are a few years old. They have no power cable (nowhere to plug a cable in either) and the aux cable has no jacks. It is just two split wires. How can I connect them to my TV?Thanks,Aaron
They need an amplifier in order to work....You attach the speakers to the amp then the amp to the TV....You could also take the plastic shell off your TV then disconnect the internal speakers of the TV and solder the wire from the speakers you have onto the wire just connected from the TV speakers...You also would probably need to drill a small hole in the plastic cabinet of the TV in order to pass the wire through... also would need to figure out the polarity of the internal wires and also the speaker wire from the cabinet speakers or satellites...also the Impedance must also match..so it could be that you would need to add a resistor in order to match the impedance of the TV's amplifier....
Q: Does it need the PCI-e power cable on the PSU
No maximum mom forums are huge-spread in they want the ATX 24pin significant plug. The could also want the 12v AUX too. regularly there's a mixture of molex and SATA connectors. maximum production unit machines do not use a extreme end video card so the wont have the PCIe video card connectors you should actually get a PSU that has extra skill than the cardboard needs AND that it comes with each and every of the connectors you want.
Q: is it possible to run a 2-wire AC power cable (2x2.5mm2 or thicker) from the telephone junction box to the inside of the house instead of using an ordinary thin phone cable? will that affect the voice quality or maybe an ADSL setup? the distance is approximately 50 meters.thanks a lot.
Two conductors are two conductors, unless there are high-frequency issues. In this case it appears that if you are replacing parallel (not twisted) wires with another set of at least equal thickness, you should be okay. Since ADSL is used on parallel wires, without twisting them, the frequencies conducted should not present problems.
Q: I'm only asking this on here out of interest, this is not homework. I want to know how to calculate exact distances between to poles connected at the top by a cable. The length or height of the objects are not important to me, but if you must use an example please do so. So I want to know what formulas to use, what variables in those formulas mean, and how the slope of the cable will affect the distance. For example, if two poles have a distance between them of 0, and the cable extends 100, it would not mean that the drop of the cable (called a catenary?) would be 50, (it's misleading because you would think that since the distance between the two poles is 0, the cable would drop 50 and rise 50. But this is not taking into account the slope it has to take at the bottom of the catenary. It must lose some drop (perhaps to 48 or 49) in order to bend and rise back up...I want this out of my head, it's bugging me that I can't figure it out.
So you want the length along the cable? I honestly don't know how to compute the arc length of a catenary, but I'm sure that the power company knows how to do it because they need to know how much cable it will take to string up a whole line of poles. Your example doesn't work only because you impose a physically impossible constraint (zero distance between the poles - the poles have no thickness) and then try to impose physical reality (the cable can't bend instantaneously) on the problem. In the physically unrealizable problem, yes the cable does drop 50 ft because it is infinitely bendable. You're dealing with hyperbolic sines and cosines. Good luck
Q: i wanna know how much distance should be in between the power cable and the cat5 cable
it could be ok at a few inches however i personally had experience where it had to be a few feet but only with power going to a florecent light... whenever light was turned on i lost net yet cat5 could be run right next to light itself or other power lines no problem.. fyi, no one could figure it out, even qwest dsl service people ( 3 in all) - ended up having to be 3 feet from just that certain power line
Q: My stereo in my car is cutting out (powering off and on again) on high volumes. I'm trying to determine if it's my amp/sub-woofer or not. I switch off my amp with my remote power switch (the blue cable switch) and I still get the cut out. Is this conclusive enough to indicate that the problem is not with my amp/subwoofer?
Ok, so this is what your going to do to test this. First unscrew your remote switch and place a wire from the positive terminal from your amp to the remote switch on your amp and then the amp should power on. now if you have the same problem it is most likely that it is not that the remote switch is having problems but probably your sub is not matched with your amp and has greater ohms than your amp is capable of therefore sending it into protect mode which would make sense since you say it is when you turn up the volume. I wish the best of luck : ) P.S check your wattage if your amp draws more than 600+ maybe even 500 your battery may not be able to power it so maybe if all else fails see if you can get your hands on a capacitor.
Q: I asked before about installation of power and control cable in the same conduit .. I think it is not a good practice.. I want to ask about installing 2 power cable each 480V in the same conduit ..Also I want to know if it is mentioned in any standard like NECthx
Article 725 of NFPA 70 (the NEC) should answer your questions regarding Class 1, 2 3 Remote-Control, Signaling, and Power-Limited Circuits and the installation requirements that apply to your specific application.
Q: It never occurred to me that the power cable -- the one connected from the outlet to the laptop's AC brick -- is rated at quot;125V - 7Aquot;. Does that mean it won't be able to handle the 240V in some countries? The brick itself is rated 100V - 240V, so it can be used internationally. In fact, I spent a year in France, where I used my Dell Inspiron just fine (with a prong adapter so it'll fit into the socket). The reason why I'm paying attention to the power cable is because the cable for my Nikon D80 battery charger has a quot;USsticker on it. The charger itself can handle 240V, but does this mean the cable cannot?
read the stuff on the adapter. if it says 120-240 then you can use internationally. if not you CAN'T use it. you have to get a transformer then which will convert electric to 120.
Q: Please, its urgent. Is it possible to use another wire? I don't have money btw.
Troll patrol a brilliant answer as far as humour goes. Your computer would normally have spare power leads in it in case you want to add other drives. if not then try taking one from your CD rom and plugging it to your hard drive. Only problem here is your system may boot from the cd rom.
Q: The Leader of the band inists that all power cables connected to the amplifires be placed away from the performance area.
a) He(she) is smarter and more experienced than you? b) He(she) wants some action on the stage and you might just kick (scuff) the cords in the process (either of which is undesirable since sudden silence in the middle of a number does not get repeat performances and sudden shorts doesn't impress too many people, either).

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords