AC drive LED T8 tube Super long service life high luminance
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 pc
- Supply Capability:
- 10000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification
Products features
1. Aaward-winning technology of 2014 Geneva International Exhibition of Inventions
Prolong the service life of T8 tube to 50,000 hours, it is 2 times as long as traditional driver.
5. High light efficiency. Use high quality SMD chips to ensure the high light efficiency
6. Low lumens depreciation. Less than 3% per year. The users needn’t to replace the tube during 4-8 years.
Perfect AC directly drive solution which won the won the 2014 Geneva International Exhibition of Inventions.
As the global leader in LED driving technology.
AC Chips replace the traditional LED driver.
The service life of AC chips more than 100,000 hours,so service life of the whole tube more than 50,000 hours.
The ueser needn't replace the tube in 4-8 years.
LED T8 tube 18W | |
Electric parameter | |
Power | 18W |
Voltage | 160~270V AC,50/60Hz |
Power Factor | ≥0.95 |
Operating Temperature | -40℃~50℃,20%~90% H.R. |
Storage Temperature | -40℃~80℃,10%~90% H.R. |
Optical parameter | |
Color Temperature | 5500-6300K |
The LED type | 5730 SMD LED |
Number of LED | 80 PCS |
Angle of LED | 120(Degree) |
Luminous Flux | 1530Lm |
Photosynthetic efficiency | ≥85Lm/W |
Physical parameter | |
Level of Waterproof | IP55 |
Service life | 50000 H |
Electrical categories | ΙClass |
Lamp cover material | High light transmittance glass tube |
Lamp cover color | Milk white |
length | 1200mm |
diameter | 26mm |
Lamp weight | 0.41Kg/0.904lbs |
Mode of package | 30Units/Ctn |
Package measurements | 1270*220*200MM |
Package weight | 15.3KG (33.8lbs) |
Revolutionary no driver LED, Alternative directly drive, high efficiency and stability
Pioneered the AC directly drive LED solution, replaced the traditional LED driver by TF-11 and G13 chips. The patented technology won the 2014 Geneva International Exhibition of Inventions. The reliability and service life of LED were improved enormously by AC directly drive solution. The service life of AC drive solution beyond surpassed 100,000 hours.
High grade luminous source
Professional encapsulated SMD 5730 with high quality LED chips ensures the LED resource obtaining excellent protection of optical attenuation and the heat conduction ratio. Reduced the optical attention rate to the minimum value as 3% per year.
Tripe heat dissipation, Super long service life
Utilizing high thermal conductivity aluminum plate, high purity glass tube, no LED driver consumption. Tripe heat dissipation design ensures the chips conducting the heat rapidly. No delay start, AC directly drive, unaffected by electric fluctuation. The service life of T8 tube more than 50,000 hours and it’s 2 times over the traditional LED driver tube. So user needn’t to replace the tube in 4-8 years.
Uniform illuminance, Comfortable visual sense
High luminous transmittance glass tube that the luminous transmittance more than 99%.
The surface was frosted without light spot. The light was soft, pure spectrum, high CRI
( color rendering index ).Without ultraviolet ray, infrared radiation, ensure a comfortable
visual sense.
- Q: Why is the household daylight lamp attached to the battery?
- No, there aren't more than 40 fluorescent lights. Anything else.How big is the tube and the battery? There is nothing else.
- Q: Can leds be used for a regular fluorescent lamp?
- LED lights do not use ballast! They work in a completely different way.
- Q: How do you measure the flux of the LED fluorescent tube
- In theory, it's measurable, and it's actually hard to set up. There are two ways of measuring flux, essentially the same thing 1: the integrating ball is measured by your illuminometer 2: set up the field aperture + your illuminometer + space station to measure by the 4PI () stereo Angle integral. The last time you said you have integral ball and light meter I suggest the first way is feasible. In addition you put not fluorescent lamp it doesn't matter, can be measured in area of block of luminous flux, and finally take the area integral. The results must be less than professional distribution photometer to measure, the standard but the data still have rigorous theory and process support.
- Q: What is the cause of the lights after the led fluorescent lights are turned off
- The third one is the most common problem of power leakage which is the small current of the power supply or the uncontrollable control
- Q: What's the difference between an LED fluorescent lamp and an ordinary light tube?
- Leds use low power, long life, low heat and high price.Although it may feel a little bit narrower at 120 degrees, most of the time, it will be enough.
- Q: What specification does daylight lamp tube have, what brand of fluorescent lamp?
- Fluorescent TUBE what are the specifications: fluorescent lamp inside is divided into traditional fluorescent lamp and led fluorescent lamp, its specifications are divided into: T4, T5, T8, including T represents the TUBE, and also is the meaning of the TUBE. The specification is: phi 26MM * 900MM, phi 26MM * 1200MM, phi 26MM * 600MM, and phi 26MM * 1500MM. The common use of the family is phi 26MM * 1200MM. For the size of the fluorescent lamp, the size is generally smaller. For example phi 26MM * 1200MM this type of fluorescent lamp, the length is usually 600 mm, the size of the garden diameter is 26MM, the other standard match size has a strict standard. Power in the power of the fluorescent lamp is generally for 9 watt, 14 w, 20 w, 30 w, 40 w, 100 w, depending on the length of the power aspect will also change.
- Q: Do not have the fluorescent lamp of actuator, how to change LED lamp tube?
- LED lamp. There are small actuators that only need to be connected, red, and black. Can.. There are other LED lights that need a different starter.
- Q: Led lamp tube t8 good or t5 good
- This depends on where it is used, and the average household or supermarket store is using a t8led lamp. The t5 lamp is used in special places
- Q: What is the reason for the movement of light in the tube
- Lamp tube problem, get a hot towel tube to wipe, sometimes can solve.
- Q: The various specifications of LED fluorescent tubes
- Normally use T8 and T5 lamp tube, the specific parameter is different, the price also is different
Send your message to us
AC drive LED T8 tube Super long service life high luminance
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 pc
- Supply Capability:
- 10000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches