General Specification:
Input Voltage: 90~264VAc 50/60Hz
Power Consumption: 18W
Power Factor: >0.95
CRI: Typical >70
Shell Material: Aluminum Base PC cover (Transparent/stripe/frosted)
Tube Length: 4ft (120cm)
LED Quantity: 100PCS SMD2835 smd led
Output Lumens: 1600-1800lm
Color Temperature: 2700~3300K (Warm White), 4500~5500K (Pure White), 6000~7500K (Cool White)
Working Temperature: -20~40C
Storage Temperature: -40~60C
Safety Compliance: CE, RoHS
Applications:
Replacement for tranditional fluorescent tubes in
1. Offices
2. Conference Centre
3. Hotels
4. Commercial Complexes
5. Residential / Institution Buildings
6. Schools, Colleges & Universities
7. Hospitals
Trade Terms:
1.Payment: T/T , 30% deposit in advance, 70% balance to be paid before shipment (Western Union is welcomed)
2. Production lead time for 100~500pcs within 7days, 500~1000pcs in10days
3.Sample can be delivered within 3 working days
4.Shipping freight are quoted under your requests
5.Shipping port: Shenzhen, Mainland China
6.Discounts are offered based on order quantities
Our service:
1.Your inquiry related to our products or prices will be replied within 24hrs.
2.Well-trained and experienced staff will answer all of your enquires and questions
3. Any kind of your customized lightings we could help you to design and put into production.
4.Distributership are offered for your unique design and some our current models
Other information:
Tube Type | Length | Power Consumption | Work Voltage | LED Quantity | View Angle | Color Temp | Lumen Output | CRI | Power Supply |
Round | 2ft | 10Watt | 90~264VAc 50/60Hz | 144pcs | 120D | 2700-3300K, 4000-5500K, 6000-7000K | 780~850lm | >70 | Non-isolated |
Isolated | |||||||||
Oval | 160D | Non-isolated | |||||||
Isolated | |||||||||
Round | 4ft | 18Watt | 288pcs | 120D | 1560~1700 lm | Non-isolated | |||
Isolated | |||||||||
Oval | 160D | Non-isolated | |||||||
Isolated |
- Q:How do the long daylight bulbs change
- One kind: rotate 90 degrees, the two feet of the lamp tube go down from the small opening slot of the lamp. Install instead.
- Q:Xinda is a popular led lighting tube
- The led tube is required to be divided into several grades. The general engineering level is high, the quality is stable, the quality assurance time is long, the price is relatively high.
- Q:How does the energy-saving lamp tube set quota
- For example, can be used in dome light, wall lamp, such as the above, set directly absorb dome light, wall lamp, if only is energy-saving lamp tube directly in the lamp on the mouth, can energy saving lamp holder.
- Q:20 square metre room application which led fluorescent lamp tube
- You can choose an 18-watt T8LED fluorescent lamp, or an 18-watt LED light bulb.
- Q:What's the difference between an LED fluorescent lamp and a regular fluorescent lamp?
- LED fluorescent lamp does not blink, save electricity, long life, do not pollute the environment.
- Q:Can the LED tube be installed as a general lamp holder? It won't burn easily
- Cannot be installed directly, need to change internal wiring. Leds are not the same as the traditional lamp tubes, which have the power supply inside the LED tube, and the input voltage at both ends of the tube is 220V. The traditional lamp power source is placed outside, and the voltage at both ends of the lamp is as high as a few hundred volts. If the LED tube is directly installed, it will burn down the power in the LED lamp tube because of the hundreds of volts of voltage that the original fluorescent lamp's ballast outputs. 3, therefore, the LED light tube cannot be installed directly in the traditional fluorescent tubes, the need to remove the internal ballast, then change the input at the ends of the line. LED bulbs are usually two incoming lines, one firewire and one zero line.
- Q:Leds are the ones that are brightest
- The full plastic tube (aluminum) > glass tube > half plastic half aluminum is recommended. The glass tube is fragile and is restricted in use.
- Q:What is the idea of an LED daylight lamp called T5 or T8?
- Integration tube: currently, mainly appears in the LED industry, design reason mainly lies in the fact that the LED itself is not easy to damage, but the LED heat emitted by itself is very big, if the cooling area is too small, easy to cause the droop is bigger, so will the lamp and stents design together at the same time can reduce the cost, and can ensure the LED light attenuation!
- Q:Fluorescent lamp double lamp tube wiring method
- Leds that do not normally require special orders are mostly built with built-in power, which is directly available. Most can only need to remove the starter on the traditional stent line (is a cylinder bracket highlighted below) mount tubes can be used, if not yet so could you use the stent is a relatively new "electronic" will be a little trouble need you open the stents to get inside the ballast also take off to the inside of the line directly connected to the utility, LED bulb is directly at the mains. Of course, if you understand the circuit and you're not afraid of trouble, it's advisable to remove the "regenerator", because the "ballast" is a power drain.
- Q:What's the difference between an LED fluorescent lamp and an ordinary light tube?
- The next part of LED color temperature: the work of various lighting fixtures... | returns the advantage of the log list LED fluorescent lamp to share the copy address log address: use Ctrl + C to copy and post it to the friend. Broadcast to weibo pig eight quit to do the monk May 17, 2011, when reading and classification (0), (4) comments: personal diary permissions: public font: set-top permissions set in small cuhk more ▼ ▼ in recommended log To illicit close log Remove the edit the led fluorescent lamp to become one of the earliest to enter indoor led lamps and lanterns, because it is relative to fluorescent lamp has 10 major advantages: 1. High luminous efficiency Fluorescent lamp luminous efficiency is about 55-80 lm/W (Philips company T8 fluorescent lamp luminous efficiency is 72 lm/W), and LED the luminous efficiency of above 100 lm/W, recently Cree company XLampXP - G luminous efficiency has been to 130 lumens/W, and will improve in the future. The difference is now nearly double. And it could be more than three times that. The efficiency of lamps and lanterns efficiency is mainly to point to effective light effect, because fluorescent lamp is 360-degree, and the light that is sent in the opposite direction has no use. So fluorescent lamp USES a white chimney normally, can take a considerable part of the reverse light reflected, in general, fluorescent lamps and lanterns of efficiency is about 70%. LED fluorescent lights are 120 degrees, so all light is efficient.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
High Lumen T8 Led Tube Light
- Loading Port:
- Shenzhen
- Payment Terms:
- L/C,T/T
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 10000 Pieces pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords