Rated voltage 0.6 / 1kV for inverter main circuit flame-retardant power cable

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
10000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.      Application

Power cable for the inverter frequency control for power transmission or connecting, the cable system is especially suitable for making paper, steel, textile, metalworking and food processing industrial pumps, blowers, conveyors, transmission lines, and air conditioning of main circuit inverter. 


2.      Type and Specification

 Voltage

0.6/1 kV

 Type

Z-BPYJVP1、Z-BPYJVP12、Z-BPYJVP3、Z-BPYJVP2

Specifications(mm2)

3+3 Core:4~300

 Standard

 Q/XLJ 0326


3.      Using features

①      Rated voltage Uo/U 0.6/1kV. 

②      Maximum allowable cable long-term working temperature: XLPE insulated cables 90 ℃, PVC insulated cables 70 ℃ 

③      Short circuit (the longest duration of no more than 5S), cross-linked polyethylene insulated cable conductor maximum temperature does not exceed 250 ℃, PVC insulated cable conductor maximum temperature does not exceed 160 ℃. 

④      Ambient temperature of cable laying should not be less than 0 ℃, the minimum bend radius of 8 times the cable diameter. 

⑤      Has a good shielding performance, can reduce the adverse effects of higher harmonics present in the inverter output. 

⑥      DC resistances of conductor comply with GB / T 3956. 

⑦      Withstand 3.5kV / 5min withstanding the test without breakdown. 

⑧      Cable retardant characteristics meet the requirements GB / T 19666. 

4.      Picture of structure


1、Conductor   2、Insulation  3、Filler   4、Tape  5、Copper wire shield   6、Copper tape shield   7、sheath


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:"Cable laying" cable cross-sectional area refers to the cable cross-sectional area, or refers to the copper core cross-sectional area
YJV22 indicates "copper core XLPE insulated, steel tape armored PVC sheathed power cable" 0.6 / 1KV indicates its pressure rating, 5 * 10 represents the cross-sectional area of each wire diameter Is square mm, referred to as the square, the diameter of the conversion is 4.05
Q:What is the difference between a pre-branch cable and a punched clip?
. soil buried pipe, including weak and fire, should be thick-walled galvanized steel pipe, that is, SC series of steel pipe, the best size is not less than SC. weak professional, decorative professional now basically use thin-walled galvanized steel pipe, that is JDG series steel pipe
Q:Yjv22 cable laying pipe when the casing with plastic or steel pipe
Second, the laying of the bracket, the power cable should be placed in the upper control cable, but 1000 volts below the power cable and control cable can be laid side by side
Q:The computer host is always start to stop, resulting in the last can not start. What is going on?
GB-2002 provides: metal cable bridge and its bracket and the introduction or extraction of metal cable ducts must be ground (PE) or zero (PEN) is reliable, and must meet the following requirements:
Q:The wall was sideways opened a trough how to do ah?
With steel wire, lead the bend round, but do not let the wire can hold the pipe wall, and sometimes also need two twisted wire, wire over the past OK
Q:The TV shows no signal. The What is the reason for this?
The domestic general by the following parts in order, some parts can be omitted: 1: category, use the first letter with the Chinese alphabet, such as K on behalf of the control cable, C on behalf of the marine cable Q car ignition line D power cable Y Mobile rubber sheathed cable H welding machine cable 2: conductor with the first letter of the Chinese alphabet said: such as T for the copper, L for the aluminum LG for the ACSR 3: Insulation material with the letter code, such as V for the PVCY Polyethylene 4: Sheath with the letter of the letter code with 35: feature code used in the first letter of Chinese spells, such as the circle with R, soft R, flat B, flat with B6: outer sheath with the number that: 22 the first representative of the steel armor, the second representative of the PVC jacket 7: derived code with a number or symbol, such as BV-withered Sichuan Fen boil let go wind sand dust 90 said temperature 90 degrees BV line can be omitted Generally have: D power cable T copper R round like VV. you control the order of the above carefully understand, which omitted the 1.2.5 three, you should see clearly.
Q:Can 110kv and 10kv cables co-share with trenches? What is the relevant specification?
According to Article 22.7.1 of the Electrical Design Code for Civil Buildings JGJ16-. the transmission lines and the electronic information system transmission lines shall be laid separately and shall be shielded when they are close to the laying of them in parallel by the construction conditions. High-voltage cable under normal circumstances is not allowed and weak cable with the ditch laying. If the relevant control cable does need to be with the high-voltage cable ditch, should be laid on both sides of the laying and keep the distance, but also pay attention to control cable shielding measures.
Q:Power cable 5-color line, respectively, what color, what role?
YJ: cross-linked polyethylene insulation V: PVC sheathed 22: steel tape armor 8.7 / 15KV: rated voltage: 8.7 / 15 kV 3 * 300: three conductor cross-section of 300 square copper conductor Another: such as YJLV Is the aluminum core. Here is not marked what the material is conductor, you can default to copper conductor.
Q:Why does the sparrow stand on the wire without electric shock?
12 meters below the road should be used to protect the tube, the use of rigid PVC pipe protection of course, but not necessarily have to wear armored cable
Q:Emergency cable T-box and cable distribution box of the information?
1 Ordinary distribution box There is no switch device in the general distribution box

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range