JRLX/T (ACCC) Composite lead
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Application: Lead JRLX/T has been designed specially for aerial electricity transportation and supply circuitry.
Advantages of using carbon fiber composite core aluminum twisted wire for transporting and supplying electricity:
●The carrying capacity is twice as that of the common aluminum twisted wire with steel core, but a new wire can be spanned without rebuilding the pole and tower. The section area of aluminum lead in the carbon fiber composite core aluminum twisted wire is 29% more than that of the aluminum twisted wire with steel core.
It can be available at 200℃, while the using temperature for common aluminum twisted wire with steel core is just 100℃.
●In fact the arc drop is removed and it will be not influenced by the long-time creep of aluminum.
●It can be installed easily by simple way, tool and aurum tool and do not need special tool or special training.
●The construction cost can be reduced by using fewer pole, tower. The span between the pole and tower can be enlarged with high intension to reduce more than 20% pole, tower.
●It has good performance to defense the environmental degradation. It does not rust or corrode and will not have an electrolysis reaction with aluminum lead or other components; it can be cyclic used.
●It can be helpful to reduce the operating cost with high operating efficiency and meet the transmission standard.
Wire loss can be reduced by 29% in the same capacitance capacity, so the content of electricity generation can be reduced and energy sources cost can be saved.
Implement regulation: ASTM or CSA ASTM Total section area of the lead 0.3819 inch(246.4mm2)
Section area of aluminum lead 431qianyuanmier(218.4mm2) Area of aluminum ring 463.4qianyuanmier(234.8mm2)
Outside diameter of cable 0.720 inch(18.29mm) Filled coefficient 93%
Diameter of composite core 0.2350 inch(5.97mm) Area of designed aluminum 431.0qianyuanmier(218.4mm2)
Quantity of composite core 1 Actual area of aluminum 431.0qianyuanmier(218.4mm2)
Layers of aluminum lead 2 Quantity of aluminum lead 16
Quantity of single line in the first layer 6 Aluminum in the first layer 37.30%
Quantity of single line in the second layer 10 Aluminum in the second layer 62.70%
Composite core
Conductivity of outside aluminum(%IACS) 63.0% All the leads accord with ASTM B857
Conductivity of core(%IACS) 0% Aluminum of 1350-O type accord with ASTM B609
Operation frequency 60Hz Far East composite glass fiber / carbon fiber core
Machine Performance:
Aluminum 1350 composite core Total
Lead weight 405 pounds/kilo feet 603kg/km 35 pounds/kilo feet 52kg/km 440 pounds/kilo feet 655kg/km
Lead area 0.3385 square inch 218.4mm2 0.0434 square inch 28.0mm2 0.3819 square inch 246.4mm2
Integrated pull power of the lead 16300 pounds (72458N)
Heat capacity 97.3w.s/ft /℉ 175.2…../ ℃
Electric performance: 60Hz
Temperature AC resistance Structure
20℃ 0.2069Ω/mile (0.1286Ω/km) JLX/T is a kind of twisted wire with echelon
25℃ 0.2112Ω/mile (0.1313Ω/km) aluminum lead of composite core in same heart.
50℃ 0.2325Ω/ mile (0.1445Ω/km) JLX/T is designed to remain same outside
75℃ 0.2539Ω/ mile (0.1578Ω/km) diameter as common aluminum lead with steel
100℃ 0.2752Ω/ mile (0.1710Ω/km) core. It matches with the composite core of
125℃ 0.2966Ω/ mile (0.1843Ω/km) smaller outside diameter, and the tight echelon
150℃ 0.3180Ω/ mile (0.1976Ω/km) aluminum lead forms TW lead, the aluminum
175℃ 0.3394Ω/ mile (0.2109Ω/km) section area of which is about 29% more than
200℃ 0.3608Ω/ mile (0.2242Ω/km) that of common aluminum twisted wire with steel core. Patented composite core of high strength shapes the lead center, on which 2, 3 or 4 layers of anneal aluminum lead(ASTM B609)of 1350-O type twist. Composite core of high strength does not rust or corrode and will not have an electrolysis reaction with aluminum lead or other components.
GMR (Geometry average semidiameter)
Inductance of 1 foot (0.3048 meter) 0.4531Ω/km (0.2816Ω/km) of 60Hz
Capacitance of 1 foot (0.3048 meter) 0.1040 MΩ/km (0.0646MΩ/km)
Intertwisted coefficient of aluminum = 1.0215
Carry flow table
Lead code: LINNET Equivalent aluminum single line diameter: 0.1641 inch (4.17mm)
Specification: 431qianyuanmier(218.4mm2) Composite core single line diameter: 0.2350inch (5.97mm)
Twisted structure: 16/1 Outside diameter: 0.720 inch (18.29mm)
Irradiation coefficient: 0.50 Aluminum conductivity: 63.0%IACS
Composite core conductivity: 0%IACS
Operation conditions: environment temperature: 25℃, Cross wing speed: 2.00 foot/second (0.61meter/second)
Operation | DC resistance | AC resistance | Carry flow without sunshine | Carry flow in the sunshine | ||||
No wind | Wind | No wind | Wind | |||||
℃ -F | Ω /kilo feet | Ω /km | Ω /kilo feet | Ω /km | A | A | A | A |
20-68 | 0.039016 | 0.1279 | 0.039184 | 0.1285 | 0 | 0 | 0 | 0 |
25-77 | 0.039827 | 0.1306 | 0.039992 | 0.1311 | 0 | 0 | 0 | 0 |
40-104 | 0.042262 | 0.1386 | 0.042417 | 0.1391 | 243 | 373 | 0 | 267 |
50-122 | 0.043885 | 0.1439 | 0.044035 | 0.1444 | 324 | 474 | 200 | 399 |
60-140 | 0.045508 | 0.1492 | 0.045652 | 0.1497 | 391 | 553 | 300 | 492 |
70-158 | 0.047131 | 0.1545 | 0.047271 | 0.15499 | 449 | 618 | 375 | 567 |
75-167 | 0.047943 | 0.1572 | 0.048080 | 0.1576 | 475 | 647 | 407 | 599 |
80-176 | 0.048754 | 0.1598 | 0.048889 | 0.1603 | 500 | 675 | 437 | 630 |
90-194 | 0.050377 | 0.1652 | 0.050508 | 0.1656 | 547 | 724 | 492 | 684 |
100-212 | 0.052000 | 0.1705 | 0.052127 | 0.1709 | 590 | 769 | 541 | 732 |
110-230 | 0.053623 | 0.1758 | 0.053746 | 0.1762 | 629 | 810 | 585 | 776 |
120-248 | 0.055246 | 0.18113 | 0.055365 | 0.1815 | 667 | 848 | 627 | 816 |
125-257 | 0.056058 | 0.1838 | 0.056175 | 0.1842 | 685 | 865 | 646 | 835 |
130-266 | 0.056870 | 0.1865 | 0.056985 | 0.1868 | 702 | 882 | 665 | 853 |
140-284 | 0.058493 | 0.1918 | .058605 | 0.1921 | 736 | 915 | 702 | 888 |
150-302 | 0.060116 | 0.19710 | .060225 | 0.1975 | 768 | 946 | 736 | 920 |
160-320 | 0.061739 | 0.2024 | .061845 | 0.2028 | 799 | 975 | 769 | 950 |
170-338 | 0.063362 | 0.2077 | .063466 | 0.2081 | 828 | 1002 | 800 | 979 |
175-347 | 0.064173 | 0.2104 | .064276 | 0.2107 | 843 | 1016 | 816 | 994 |
180-356 | 0.064985 | 0.2131 | .065086 | 0.2134 | 857 | 1029 | 831 | 1007 |
190-374 | 0.066608 | 0.2184 | .066707 | 0.2187 | 885 | 1055 | 860 | 1034 |
200-392 | 0.068231 | 0.2237 | 0.068327 | 0.2240 | 912 | 1080 | 888 | 1060 |
Sunlight condition: Circuitry azimuth angle: 270℃ Sunlight angle:83℃ Sunlight azimuth angle: 180℃ Daylight absorption: 0.5 Total sunlight and radiant heat of the sky: 96.0W/square foot Height: height 0 foot; Operation frequency: 60Hz |
Other types
Product code | Total section area of the lead | Section area of aluminum lead | Area of aluminum ring |
Hawk | 0.5415 inch2 ( 349.4mm2 ) | 611qianyuanmier(309.6mm2 ) | 657.0qianyuanmier(332.9mm2 ) |
Dove | 0.6328 inch 2 ( 408.3mm2 ) | 713qianyuanmier(361.3mm2 ) | 766.7qianyuanmier(388.5mm2 ) |
Grosbeak | 0.7215 inch 2 ( 465.5mm2 ) | 816qianyuanmier(413.5mm2 ) | 877.4qianyuanmier(444.6mm2 ) |
Drake | 0.9112 inch 2 ( 587.9mm2 ) | 1020qianyuanmier(516.8mm2 ) | 1087.4qianyuanmier(551.0mm2 ) |
Cardinal | 1.0531 inch 2 ( 679.4mm2 ) | 1222qianyuanmier(619.2mm2 ) | 1314.0qianyuanmier(665.8mm2 ) |
Bittern | 1.3283 inch 2 ( 857.0mm2 ) | 1572qianyuanmier(796.5mm2 ) | 1690.3qianyuanmier(856.5mm2 ) |
Lapwing | 1.6608 inch 2 ( 1071.5mm2 ) | 1966qianyuanmier(996.2mm2 ) | 2114.0qianyuanmier(1071.2mm2 ) |
Chukar | 1.8836 inch 2 ( 1215.2mm2 ) | 2242qianyuanmier(1136.0mm2 ) | 2410.8qianyuanmier(1221.6mm2 ) |
Bluebird | 2.2777 inch 2 ( 1469.5mm2 ) | 2727qianyuanmier(1381.8mm2 ) | 2932.3qianyuanmier |
- Q:please tell me and same question except for 6 pin cause i have one of each
- If you buy a high-end video card, it may need an auxiliary power cable plugged into it. It's easy to forget these if you're not accustomed to needing one. The auxiliary cable is probably going to be a 6-pin PCI-Express power cable, possibly a pair of them, and the latest video cards may even use a brand-new 8-pin design.
- Q:the power cable is in 2 parts, one from the xbox to a box, from the box to the wallthat box has an led light. when the xbox is on, it should turn green, when the xbox is off it should turn orange. my led light is turning red instead of orange and green.its not red ring of death, or 4 red rings, i know this because my xbox wont even power up because the box in the power cable will not send power to my xbox. im so confused...plz help
- i don't know my friend. try calling MS.
- Q:holes to route the cable through anyone have pics or a website so i can figure it out
- steering rod boot or drill a hole
- Q:I can't find out where to put my SATA data cable at... My computer has a SATA power cable though, but I can't seem to find where to put the SATA data cable, I have the data cable in my hand. Can somebody help me? Since I have a SATA power cable in my PC does it mean I can put a SATA data cable in my PC? My PC is a: hp compaq, model: DPS-240EB, if that helps...
- Still sort of hard without much more info or actually looking at the motherboard. The numbers you found are actually the power supply model number, not the whole computer model number. It could help knowing exactly what motherboard you're looking at however I'd start looking along the lower part of the board or the bottom right area. If you find a plug that it would fit in - it should be labeled very very tiny print saying SATA next to the plug-in.
- Q:my power cord on my laptop is acting up to the point where I have to literally hold it in place to have it charge the battery and now the computer isn't coming on- the battery light is showing up when you push the power button but i don't know if it is charging-if there is anything you can tell me to fix this, that would be great!!
- My power cable was having a problem too. What I did was just go out and get another cable because it seems that it is either your battery, or your power cable. So just go out get it replaced and Wala! It should work again...
- Q:Cable 3 (4 × 185 + 1 × 95) What does it mean?
- According to Article 22.7.1 of the Electrical Design Code for Civil Buildings JGJ16-. the transmission lines and the electronic information system transmission lines shall be laid separately and shall be shielded when they are close to the laying of them in parallel by the construction conditions. High-voltage cable under normal circumstances is not allowed and weak cable with the ditch laying. If the relevant control cable does need to be with the high-voltage cable ditch, should be laid on both sides of the laying and keep the distance, but also pay attention to control cable shielding measures.
- Q:I have lost the power cable which came with my computer's PSU and after looking online for a while the online shops seem to sell the power cables with little information about whether or not they will function with different PSUs so I am guessing it doesn't matter which one I buy.
- They are not special just a kettle lead really and should cost less than $5 as said if it fit it is good, look around you probably have one lying around
- Q:the cable that comes out of the ocean and goes onto the island. Sayid finds it
- The underwater Dhrama Looking Glass station. Remember from the season finale of season 3 I believe, it's where Desmond and Charlie swam to to press the button thing to allow communication with the outside world, but those two women were there and then Mikhail showed up and Charlie ended up drowning after Mikhail threw a grenade at the control room Charlie was in, but before Charlie drowned he managed to tell Desmond that the freighter was not Penny's boat.... ringing a bell? The cable was to provide power to it.
- Q:Can I use 300 v power cable on a cx500?
- The volt is not a unit of power. As the voltage supply in any country is 100V-240V then your cable is o.k. The important thing is the gauge ie the current (Amps) it can carry. As the mains power circuits in most countries is fused at 13Amps - 16Amps your cable has to be safely above that Amps are the thing that will cause a cable to overheat and catch fire Therefore check the gauge of you cable
- Q:i bought a car from some guy..he had 2 amps but he took out one...he had the power cable running from one amp to the other. i just recently bought another amp and i was wondering if its safe to do this.he said it was working fine..he was powering 2 10 subwoofers..thats what im planning to do
- its safe but its better to run 2 separate wires due to you are wanting to use more power and one wire has a max load that it can handle...you run 2 and you will have more power to each amp
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
JRLX/T (ACCC) Composite lead
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords