Frequency Inverter Single-phase 380V class 0.75KW

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
100000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

General

 

CNBM  frequency  inverter is a high-quality, multi-function,

low-noise variable frequency drive which is designed, developed and manufactured according to international standards.

It can meet different needs of industrial conditions.

The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse.

 

 

Product Name:CMAX-VCG15/P18.5T3 ~ CMAX-VCG18.5/P22T3

 

Application

 

 

Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.

 

Plastic: extruder, hauling machine, decorating machine, etc.

 

Pharmacy: mixer, roaster, etc.

 

Woodworking: engraving machine, sander, veneer peeling lathe, etc.

 

Papermaking: single type papermaking machine, etc.

 

Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.

 

Printing: cloth-washing machine, dye vat, etc.

 

Cement: feeder, air blower, rotary furnace, mixer, crusher, etc

 

Fan and pump: kinds of fans, blowers and pumps

 

 

Specification

Item

Specification

Input

Input voltage

220/380V±15%

Input frequency

47~63Hz

Output

Output voltage

0~input voltage

Output frequency

0~600Hz

Peripheral interface characteristics

Programmable digital input

4 switch input, 1 high-speed impulse input

Programmable analog input

AI1: 0~10V input

AI2: 0~10V input or 0~20mA input,

Programmable open collector

output

2 Output

(3.7kW and above: 1 Open collector output)

Relay Output

1 Output (3.7kW and above: 2 Relay output)

Analog output

2 Output, one is 0~10V,

another is 0~20mA or 0~10V

Keypad

Display:5-digit 8-section LED (Red), 2 indicators; parameter setting: 8 keys (including multi-function hot key ), 1 potentiometer

Technical performance characteristics

Control mode

All digital space voltage vector SVPWM algorism

Overload capacity

G purpose: 150% rated current 60s

P purpose: 120% rated current 60s

Speed ratio

1: 100

Carrier frequency

1.0~10.0kHz

Torque compensation

Linear, multi-point, 1.3th power, 1.7th  power, 2.0th power reduced torque; Compensation voltage range: automatic compensation and manual compensation 0.1~10%

Automatic voltage adjustment

It can automatically maintain output voltage constant when grid voltage fluctuates.

Automatic current adjustment

When the current is over current limit, under clocking automatically limits output current.

Function characteristics

Frequency setting mode

Keypad digital analog input, keypad potentiometer, impulse frequency, communication, multi-step speed and simple PLC, PID setting and so on, switch-over of setting modes.

Simple PLC,

multi-step speed control

16-step speed control

Special function

Traverse control, length control, time control

QUICK/JOG key

User-defined multi-function hot key

Protection function

Over-current, Over voltage, under-voltage, over-heat, phase failure, over-load and motor over-load

Working condition

Installation site

Indoor, altitude of less than 1km, dust free, non-corrosive gases, no direct sunlight

Application environment

-10°C~+40°C, 20~90%RH (no dew)

Vibration

Less than 0.5g

Storage temperature

-25°C~+65°C

Installation type

Wall-mounted type, floor cabinet type

Cooling mode

Air-forced cooling

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Knowledge, principle and operation method of frequency converter.
The three major parts of the working principle of frequency converter:This is how the inverter works, but how does it work? Mainly composed of three components. (1) convert the power frequency power to the rectifier of the DC power: it transforms the power frequency power into the DC power supply. A reversible converter can also be constructed using two sets of transistor converters, which can be regenerated for their reversible power direction. (2) absorption in the converter and inverter voltage generated by the pulsating "flat wave circuit" in the rectifier DC voltage is rectified, ripple voltage with power frequency 6 times, in addition the pulsating current generated by the inverter to the DC voltage fluctuation. (3) the DC power conversion for AC power rectifier with "inverter": instead, the inverter is DC power converter for AC power required frequency, to the time the 6 switch off, you can get 3 phase AC output.
Q:What is the working principle of elevator frequency converter?
The basic principle of VVVF elevatorAccording to the theory of motor, the speed formula of AC motor is:N=60f (1-s) /pUpper type: F is the stator frequency, and P is the pole count;S is slip; n is speed.
Q:What is called vector converter?
In the electrical field is mainly used for the analysis of AC power, such as the analysis of the motor, etc., in the application of inverter in motor analysis based on the theory of frequency control, called vector control inverter, the method is not unique, but a basic mathematical model.
Q:What are the differences between electronic governor and frequency converter in motor speed regulation?
The electronic governor is used to change the power supply voltage of the motor by controlling the turn-on angle of the thyristor, so as to change the characteristic curve of the motor to change the speed of the asynchronous motor. Its characteristics are as follows: the motor speed adjustment range of small, low speed motor with load capacity, speed is reduced, the motor torque decreases, not for constant load moment, when the speed is low, easy blockage phenomenon; generally applies only to fan type load.
Q:What is the difference between inverter energy consumption braking and motor energy consumption braking?
The reverse brake has one of the biggest disadvantages: when the motor speed is 0, if the power supply is not removed in time, the motor will reverse. There are two methods to solve this problem: 1, in the control loop of the motor power supply phase, adding a time relay, when the brake after a period of time, disconnect the power after inversion, so as to avoid motor reversal. But the braking time is difficult to estimate because of this method, so the braking effect is not accurate. 2. A speed relay is added to the control circuit of the motor's inverting power supply. When the sensor detects the speed of the motor is 0, the inverter power of the motor is cut off in time. Because of this method, the speed relay monitors the motor speed in real time, so the braking effect is much better than the last one. It is precisely because reverse braking has this characteristic, therefore, it is not allowed to reverse the machinery, such as some lathes, etc., the brake method can not use reverse braking, and can only use energy consumption braking or mechanical brake.
Q:How does the PLC process the inverter output signal?
Frequency converter frequency signal will actually be converted to 4-20mA signal output, access to the PLC AI channel, SIEMENS 200 PLC, some CPU module comes with AI input, but also has a dedicated AI expansion module. What's left is software programming
Q:What do you mean by the capacity of the inverter and the capacity of the motor?
That's not the case at all"Capacity" and "power" are essentially different. Usually we say that a large transformer capacity is how much KVA, but not to say how much KW, because the two are not the same thing
Q:What does "frequency" in household appliances mean?
The air conditioner in Japan is gradually changed from pure PWM control to PWM ten PAM mixed control mode. The speed is controlled by PWM, U / F to maintain; when the speed exceeds a certain value, the system will adjust the fixed at the maximum value near, by changing the DC chopper on duty LL, improve the inverter input DC voltage, so as to keep the inverter output voltage and speed is proportional to the area, said PAM area
Q:Can the frequency converter 7.5KW take the motor with 11KW?
A motor with variable torque with a constant torque converter, which is permissible. But the load and the motor are constant torque, and the frequency converter is also constant torque, so doing is the small horse cart. No, not recommended. Because the actual click can work continuously load is only 5.5kW, and then big, frequency converter can not stand.
Q:How to maintain the frequency converter will not damage, or regular maintenance?
1. cooling fan, inverter power module is the most serious heating device, the continuous heat generated by the work must be promptly discharged, the general fan life of about 10Kh-40Kh. According to the continuous operation of converter for 2-3 years, it is necessary to replace the fan2. filter capacitor, intermediate circuit filter capacitor: also called electrolytic capacitor, its main function is to smooth the DC voltage, absorb the low-frequency harmonic in dc.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range