• Frequency Inverter Single-phase 380V class 0.75KW System 1
Frequency Inverter Single-phase 380V class 0.75KW

Frequency Inverter Single-phase 380V class 0.75KW

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
100000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

General

 

CNBM  frequency  inverter is a high-quality, multi-function,

low-noise variable frequency drive which is designed, developed and manufactured according to international standards.

It can meet different needs of industrial conditions.

The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse.

 

 

Product Name:CMAX-VCG15/P18.5T3 ~ CMAX-VCG18.5/P22T3

 

Application

 

 

Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.

 

Plastic: extruder, hauling machine, decorating machine, etc.

 

Pharmacy: mixer, roaster, etc.

 

Woodworking: engraving machine, sander, veneer peeling lathe, etc.

 

Papermaking: single type papermaking machine, etc.

 

Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.

 

Printing: cloth-washing machine, dye vat, etc.

 

Cement: feeder, air blower, rotary furnace, mixer, crusher, etc

 

Fan and pump: kinds of fans, blowers and pumps

 

 

Specification

Item

Specification

Input

Input voltage

220/380V±15%

Input frequency

47~63Hz

Output

Output voltage

0~input voltage

Output frequency

0~600Hz

Peripheral interface characteristics

Programmable digital input

4 switch input, 1 high-speed impulse input

Programmable analog input

AI1: 0~10V input

AI2: 0~10V input or 0~20mA input,

Programmable open collector

output

2 Output

(3.7kW and above: 1 Open collector output)

Relay Output

1 Output (3.7kW and above: 2 Relay output)

Analog output

2 Output, one is 0~10V,

another is 0~20mA or 0~10V

Keypad

Display:5-digit 8-section LED (Red), 2 indicators; parameter setting: 8 keys (including multi-function hot key ), 1 potentiometer

Technical performance characteristics

Control mode

All digital space voltage vector SVPWM algorism

Overload capacity

G purpose: 150% rated current 60s

P purpose: 120% rated current 60s

Speed ratio

1: 100

Carrier frequency

1.0~10.0kHz

Torque compensation

Linear, multi-point, 1.3th power, 1.7th  power, 2.0th power reduced torque; Compensation voltage range: automatic compensation and manual compensation 0.1~10%

Automatic voltage adjustment

It can automatically maintain output voltage constant when grid voltage fluctuates.

Automatic current adjustment

When the current is over current limit, under clocking automatically limits output current.

Function characteristics

Frequency setting mode

Keypad digital analog input, keypad potentiometer, impulse frequency, communication, multi-step speed and simple PLC, PID setting and so on, switch-over of setting modes.

Simple PLC,

multi-step speed control

16-step speed control

Special function

Traverse control, length control, time control

QUICK/JOG key

User-defined multi-function hot key

Protection function

Over-current, Over voltage, under-voltage, over-heat, phase failure, over-load and motor over-load

Working condition

Installation site

Indoor, altitude of less than 1km, dust free, non-corrosive gases, no direct sunlight

Application environment

-10°C~+40°C, 20~90%RH (no dew)

Vibration

Less than 0.5g

Storage temperature

-25°C~+65°C

Installation type

Wall-mounted type, floor cabinet type

Cooling mode

Air-forced cooling

 

 

Q:It was when processing a workpiece, processing spindle stops suddenly (other are normal) a check is, I jump out of the inverter, I can click on a processing, and then processing not long after they happen, (do not open the machine spindle machining will also be the case)
Has the frequency converter been used for a long time? The inverter power placed on the two day, and then open, put the line inside the head plug again, and then boot general can solve the problem, new don't try
Q:How does frequency converter realize variable frequency speed regulation?
The technique of alternating current control by changing the frequency of alternating current is called frequency conversion technology. The frequency converter usually uses the on-off function of the power semiconductor device to change the power frequency power to another frequency energy control device.
Q:What is the working principle of elevator frequency converter?
Elevator inverter is generally voltage type AC DC AC converter. The basic construction consists of three parts:1, rectifier circuit, alternating current into direct current2, DC bus, energy storage link, the completion of reactive power exchange in the link, the inverter can obtain higher input power factor.3, inverter, DC inverter to variable frequency and amplitude of alternating current, so that the motor work at different speeds.For detailed transducer principles, see attachment.
Q:How does the PLC process the inverter output signal?
1. The analog signals of the converter (such as the 4~20mA signal) are received in the analog input module of the PLC (for example, the EM235 module)2, the input signal processing (32000 digital quantity into 50HZ frequency signal)3. Compare the resulting frequency signals with their own internal settings
Q:Can the motor with frequency converter directly wave the insulation?
May notBecause the shaking meter used when shaking insulation, although the output is direct current, but after conversion, the voltage will exceed the rated voltage of the motor much, the only way to test the motor winding to the ground and interphase insulation.
Q:How to choose frequency converter?
1. the power of the inverter is selected according to the load power. How many power motors should be chosen for a multi power motor?. Size one is ok.2. frequency converter model, different uses, choose different frequency converter. For example, there are general frequency converter, fan, water pump dedicated inverter, a machine tool spindle dedicated inverter. Wait。
Q:What does "EPCU" mean in a frequency converter?
This code indicates external signal interference.It is possible that the power line and the signal line are coming together to check that the ground of the converter is ready.If not yet, that can only be considered in the inverter output end of the inverter output filter, or inverter output reactor to try.Frequency converter (Variable-frequency, Drive, VFD) is the application of frequency conversion technology and microelectronics technology, by changing the power supply frequency of the motor to control AC motor power control equipment.
Q:What does the base frequency 60Hz represent in the inverter?
For example: if the rated frequency of the motor is 20HZ, the fundamental frequency should be set to 20HZ; if the rated frequency of the motor is 33.3HZ, the fundamental frequency should be set to 33.3HZ; if the rated frequency of the motor is 50HZ, the fundamental frequency should be set to 50HZ; if the rated frequency of the motor is 60HZ, the fundamental frequency should be set to 60HZ; if the rated the working frequency of the motor is 100HZ, the fundamental frequency should be set to 100HZ.
Q:Can a power converter be used in a motor with small power? Will it burn the motor?
Can a power converter be used in a motor with low power, depending on your load and what type of converter is it?.If it is only a common fan, water pump or light load operation, then basically no request, you can use, as long as the relevant parameters can be set.
Q:Where is the difference between soft starter and converter?
The soft starter changes the supply voltage only and is equivalent to a step-down starter. The frequency converter is much more complex and much more expensive than the soft starter. The inverter also has a soft start function, which is achieved by changing the power frequency. Difference between high voltage starter and low voltage starterThe main circuit of the soft starter is thyristor, and the start-up process is completed by gradually changing the turn-on angle of the thyristor. This is the basic principle of the soft starter. In the low-voltage soft starter market, a wide range of products, but high voltage soft starter products are still relatively small. High voltage soft starter is the same as low voltage soft starter, but there are some particularities in high voltage soft starter and low voltage soft starter:

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords