Online UPS 10KVA 8KW

Ref Price:
Loading Port:
Shekou
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Online UPS 10-20KVA

The XPC series 10-20K series is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. XPC series 10-20K series UPS provide customers safe and sound power supply.

Excllent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material
with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the
optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard
the ups security when operation in bad environment.

Ientelligent management of battery charging and discharging
The advanced battery intelligent charging technology enables the UPS's charger to rectify the charging parameter,
and provide the optimum charging modes in the different environment, types and amounts of cells, and the using
condition of the battery. The scientific charging mode extends the battery's lifetime. The optional addition to
charging units shortens battery charging time.

Front board operation and maintenance
The smart module design and front board design make the users operation more conveniently and easily.

Remote monitoring
Communication interfaces like RS232/RS485, Intelligent Slot of JingFuYuan Company are available for the realization
of remote management and monitoring.

High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output
and reliability.

Outstanding electric property
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help reduce the
power loss of UPS. Because of the technology of IGBT FM intelligent rectifier and inverter is used , the input power
factor is as high as 0.99,and the input current harmonic wave is as low as 3%,which makes the output voltage electric
property more extraordinary.
Powerful overload capacity: the ups can work normally up to 10 mins under the condition of 110-125% load and 1

minute in load of 125-150% . It also has the output short circuit protection capability.


MODELXPC 3110LXPC 3115LXPC 3120L
Rated Power10KVA/8KW15KVA/12KW20KVA/16KW
INPUT
Phase3W+N+G
Input Voltage(207-475)VAC
Input Frequency(46-54)Hz
Input PF>0.95
Bypass voltage(302-437)VAC
OUTPUT
Output Voltage220VAC±1%
Output Power Factor0.8
Output FrequencyNormal modesame with utility power
Battery mode
49.950.1Hz
THDTHD<3% (linear load)THD<5% (non-linear load)
Transfer TimeNormal to battery mode: 0ms
Bypass mode to normal : 0ms
Overload Capabilityload105±5%normally runnormal modeturn to normal mode after overload disappearing
105±5%
load135±5%60s
135%
load150±5%30s >150%:0.1s
BATTERY
Voltage192Vdc
Charging voltage220Vdc
Overvoltage230Vdc
Charging Current2A/4A(L type)
SYSTEM
Efficiency>92%
CommunicationLCD display+RS-232 + Intelligent slot
Restart FunctionAfter turning off due to cut off voltage of battery, UPS will restart
when voltage is in (302~437Vac) and frequency is in (47~53Hz).
Noise (1m front)<45dBA<50dBA
Operation Temperature0°C to 40°C
Humidity095% non-condensing
Storage Temperature-40°C to 50°C
Altitude1000m
Dimension(WXDXH)248×500×616
Weight(kg)273535
Specification is subject to change without prior notice.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:UPS power supply working principle
Online online UPS (On-Line UPS) mode of operation for electric and electric equipment is isolated, electricity will not direct power supply for the electric equipment, but the UPS is converted into DC, then diverge, a way to charge the battery, another way to alternating current. The power supply for the electric equipment, electric power quality instability or power outage, the battery from charging into electric power supply, until the city returned to normal only to charge, "UPS is involved in the entire process in the whole process of electricity". The utility model has the advantages of output wave and electricity for the same is pure sine wave, and no noise, no influence electrical instability, can supply power to the "inductive load", such as the electric fan, as long as the premise UPS enough output power, can supply power to any use of electricity equipment.
Q:UPS (uninterruptible power supply inverter operation principle and practical role in UPS)
UPS power supply working principle(1) onlineOnline UPS (On-Line UPS) mode of operation for electric and electric equipment is isolated, electricity will not direct power supply for the electric equipment, but the UPS is converted into DC, then diverge, a way to charge the battery, the other way is to supply power to the alternating current. Electric equipment, electric power quality instability or power outage, the battery from charging into electric power supply, until the city returned to normal only to charge, "UPS is involved in the entire process in the whole process of electricity". The utility model has the advantages of output wave and electricity for the same is pure sine wave, and no noise, no influence electrical instability, can supply power to the "inductive load", such as the electric fan, as long as the premise UPS enough output power, can supply power to any use of electricity equipment.
Q:What if UPS doesn't work properly?
Have power output of UPS is normal, and no power when the buzzer ringing, no output.Fault analysis: judging from the phenomenon of the battery and inverter part of the fault, the following procedures can be checked:Check the battery voltage to see if the battery is charged enough. If the battery is not charged enough, check the battery itself or the charging circuit fault.If the battery operating voltage is normal, check whether the inverter drive circuit is working properly. If the output of the drive circuit is normal, the inverter is damaged.If the inverter drive circuit is not working properly, then check the waveform generation circuit, whether there is PWM control signal output, if there is a control signal output, indicating the fault in the inverter drive circuit.If the waveform generator circuit does not have the PWM control signal output, it will check whether the output is blocked due to the protection of the circuit. If so, the cause of the protection will be found out;If the protection circuit is not working and the working voltage is normal, and the waveform generating circuit has no PWM waveform output, the waveform generation circuit is damaged.The sequence can also be reversed, and sometimes faults can be detected more quickly.
Q:Do you have the offline UPS?
UPS has the following basic functions:1. normal voltage, the voltage through the UPS voltage supplied to the load, the good performance of the UPS AC regulator itself is good; it is also in charge of the battery for storage, backup energy.2. when the grid voltage is abnormal (undervoltage, overvoltage, power loss, interference, etc.), the UPS inverter converts the DC energy of the battery pack into alternating current, which can maintain the power supply to the load.The 3.UPS automatically switches between the power grid and battery power to ensure uninterrupted power supply to the load. General computer equipment allows a small power interruption (within switching time 10ms), but the computer equipment and communication equipment precision is not allowed with intermittent power (switching time 0ms), it should be confirmed exactly how much time you need to switch UPS.
Q:What is pure online UPS?
On line UPS means that no matter whether the network voltage is normal, the AC voltage used by the load will go through the inverter circuit, and the inverter has been in the working state. Therefore, when the power failure occurs, the UPS can immediately convert the stored power into the AC through the inverter to supply power to the load, thus achieving the switching target of zero output voltage interruption.
Q:How does PLC use UPS?
PLC, like other electronic products, has different powers, with enough sizes of UPS,Generally requires more than equipment, maximum power +30% is safe
Q:What is the UPS power supply system?
Scientific and rational use of UPS, so that UPS in good working condition, can extend its service life, reduce operating failure rate.
Q:How does the UPS power supply work?
You can take UPS power and then connected to the computer, to prevent power outages, immediately shut down, its main function is in power, but also can support the computer boot for about 10 minutes, so you can save some unsaved information
Q:A server that maintains power close to 320W and runs over 8 hours of UPS power
500+300+320=1120W can choose 2KVAS UPS power, external 12 12V100AH batteries (can be delayed more than 8 hours), external 18 12V100AH batteries (can delay 12 hours), need to Q me
Q:Is the emergency output voltage of UPS DC or AC?
When the power input is normal, UPS electric voltage supplied to the load, the UPS is an AC power regulator, it is also the built-in battery; when the power interruption (outage), UPS will immediately machine battery power,

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range