Frequency Inverter Single-phase 200V class 315KW

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Technical specifications

Table 2.3: Technical Parameters of QD200 Series Frequency Inverters

ITEM

SPECIFICATIONS

Main

Input

Rated voltage and frequency

Single-phase 200V class:  200V-240V,50Hz/60Hz

3-phase 400V class:  380V-480V , 50Hz/60Hz

Allowable value of change

Voltage: 380V-15% ~ 480V+10%;  Frequency: ±15%

Main output

Output voltage

Maximum output voltage equals to input voltage

Output frequency

0.5 Hz to 400 Hz

Overload capacity

150% of rated output current for 60s, 200% of rated output current for 2s

Control performance

Modulation mode

3-phase PWM, 2-phase PWM

Control mode

V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving

Setting method of run command

Outer terminal, keyboard panel or serial communication

Setting method of speed command

Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal

Speed setting resolution

Keyboard: 0.1 Hz

Analog setting: 0.05/50Hz (10bit)

Speed control precision

V/f control:±2%

vector control without PG (open loop control): ±0.2%

Speed control range

V/f control 1:40

vector control without PG (open loop control)  1:200

Acceleration and Deceleration

Time

0-3200.0s

switching frequency

1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency

Analog input

Number

2 ways: AI1、AI2

Type

DC voltage or DC current

Maximum input range

AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable

AI2: 0 to 10VDC or PTC probe input receivable

Analog output

Number

1 way: AO1

Type

DC voltage or DC current

Maximum input range

Voltage output: 0 to 10V, Current output: 0/4 to 20mA

logic input

Number

0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2

15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2

note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic)

Type

Source or Sink

Maximum input range

0-24VDC

ITEM

SPECIFICATIONS

logic output

Number

0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C

15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C

pulse signal output

OC,output frequencycurrentoutput、ect other function

relay output

RA-RB-RC, including a NO contact and a NC contact

Maximum switch capacity:

T1A,T1B: 3A at 250VAC, or 4A at 30VDC

T2A,T2B: 2A at 250VAC or 30VDC

Serial communication interface

RS485 interface supports Modbus protocol.

Display

4-digit LED digital display

For display of frequency setting, output frequency, fault code and parameter setting etc.

Environment

Standard

Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.

Altitude

Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m)

Ambient environment

0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating.

Storage: -25 ~ 70°C

Humidity

No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3

Impact strength

15gn for continuous 11ms, In accordance with IEC/EN60068-2-27

Maximum antipollution capacity

Class 2, in accordance with IEC/EN61800-5-1

Structure

Protection level

Top: IP41 (without removing the protective top cover). Other parts: IP20

Cooling Method

Forced Air cooling

Installation method

Wall mounted

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Asus notebook power adapter how to open
Can only be forced to open the pants and other things wrapped around the line on the line suggested that do not casually demolition
Q:Three-phase motor, quadrupole asynchronous motor to 15rpm, the inverter output how many volt voltage? The 4 V
The voltage does not change, but the frequency changes, about 0.5 Hz
Q:Variable frequency pump pressure in the very low flow instability, why?
From the performance curve, the flow becomes smaller, the combination of pressure and frequency adjustment flow will only stabilize the flow at a small value, the pressure will be reduced, because the work point will move down.
Q:Is the laptop power adapter long-haul?
Can, rarely say there is a power adapter without power and failure, my notebook 5 years, never pull the power adapter plug, never power, there is no problem. Of course, save electricity and care from the point of view, it is recommended to pull the best, because the adapter is still in the working state.
Q:The inverter control power is also the same, the pole is not the same as the motor 6 or 4 pole can be used?
Can be used, but is being used in the motor replacement, you need to change the frequency conversion.
Q:How to make the motor speed (control speed), can not use frequency
In general, the torque generated by the motor is reduced with decreasing frequency (decrease in speed), and the reduced actual data is given in some frequency converter manuals. By using the flux vector control of the inverter, will improve the motor at low speed torque, even in the low speed area motor can also output enough torque. When the frequency converter to speed up to 60Hz frequency, the motor output torque will reduce the normal motor is designed to 50Hz (60Hz) voltage, the rated torque is given in this voltage range. So the rated frequency under the speed is called constant torque speed, the inverter output frequency is greater than 50Hz frequency, the motor torque to be inversely proportional to the frequency of the relationship between the decline. When the motor is running at a frequency greater than 60 Hz, the magnitude of the motor load must be taken into account to prevent the motor output torque from being insufficient. For example, when the torque generated by the motor at 100 Hz is about to be reduced to about 50 Hz, the torque is generated. So the rated frequency above the speed is called constant power speed.
Q:How to learn the inverter debugging and design parameters
You can find the basic inverter manual, see a few times to try, under normal circumstances, the inverter on the use of manual functions such as research to understand that most of the applications are no problem.
Q:What is the difference when using inverter frequency conversion ordinary motor and variable frequency inverter motor
2, the ordinary asynchronous motor is the cooling fan and motor spindle connection, the motor speed determines the cooling fan speed, low frequency when the motor rotation is slow, so the motor temperature rise is the principle.
Q:Oil-free vertical vacuum pump why a little negative pressure inverter on the torque limit
Here is not the inverter can solve the problem, you should first 220V single-phase AC rectifier for the DC (full-wave rectifier plus filter about 310 volts),
Q:Do not the laptop directly connected to the power adapter?
4, but you can use the external 14 ~ 20V battery, connected to the matching power plug for the notebook power supply, the effect and the use of the same power adapter.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range