90KW AC Motor Use Converter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1pc pc
- Supply Capability:
- 8000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Description of 90KW AC Motor Use Converter Frequency
90KW AC Motor Use Converter Frequency is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features of 90KW AC Motor Use Converter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control
2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure of 90KW AC Motor Use Converter Frequency
Application of 90KW AC Motor Use Converter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.
★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance of 90KW AC Motor Use Converter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q:How does the spindle drive system of the inverter realize the positive and negative control of the main pole?
- Communication can reach a longer and more stable, generally better of the city 485
- Q:The notebook power adapter flashes
- 1: Check the socket with a multimeter is normal, the supply voltage is 220V. If the utility voltage is not normal, it is recommended to replace the use of environmental testing. 2: Check with the multimeter whether the output voltage and current of the power adapter match the label. If the gap is very large, and the mains voltage is normal, you can determine the power adapter failure, need to replace the laptop power adapter. 3: If the above check is normal, remove the laptop battery, do not external adapter. Press and hold the notebook power button 5 seconds to repeat 3 times. After releasing the notebook residual charge, insert the power adapter separately, power on the test. 4: If the fault persists, check the notebook's power connector, whether the exception. Such as loose or the appearance of damage and so on. 5: the above checks are normal, basically can be a preliminary judgment is the notebook motherboard failure. Recommended repair service station.
- Q:55 瓩 4 pole motor with a frequency of one hour can save much electricity
- it is used in the fan pump load can save about 14-22 kWh, used in the general category, on Multiply your number by 55.
- Q:What is the difference when using inverter frequency conversion ordinary motor and variable frequency inverter motor
- So that mainly depends on your application and the frequency of work in the number.
- Q:Inverter ACS355 If the speed is outside the allowable range, how to set the limit value
- Remember, 2001 this should be set to a negative number, set to a positive number of your speed will never be less than this value.
- Q:In the official website to buy ThinkPad notebook, to the power adapter?
- Tak City gifted, genuine low, 7 days unconditional return. 300 brand-name notebooks for you to choose.
- Q:Can the laptop's power adapter be used for years?
- In the power adapter has a nameplate, marked above the power, input and output voltage and current and other indicators, with particular attention to the input voltage range, which is the so-called "travel power adapter", if the city voltage to only 110V country , This feature is very useful, and some parallel notebook computers are sold only in the origin, there is no such compatible voltage design, or even only a single 110V input voltage, in our 220V mains voltage will be burned to burn.
- Q:Motor nameplate on the standard 2P, I set the number of motor pole in the inverter, is set 2 or 4 pole?
- Then the motor nameplate on the standard 2P, it must be 2-pole motor, synchronous speed = 60 seconds x frequency (mainland 50Hz) / pole pairs, you can also look at the rated motor speed, about 2940 rev / 60s, so the inverter Set the number of motor poles, is set 2 pole, I hope you can be satisfied.
- Q:Do not the laptop directly connected to the power adapter?
- 3, the notebook internal circuit using low-voltage direct current work, if the direct use of 220V AC and its connection will burn the circuit in the low-voltage devices, which is absolutely prohibited, but also basic common sense. At the same time, its external power jack is also dedicated, and the AC outlet is different;
- Q:Three sets of batteries (540V) DC power supply U / f inverter.
- It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.
1. Manufacturer Overview |
|
---|---|
Location | Liaoning,China |
Year Established | 2001 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO9001 |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | DALIAN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b)Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
90KW AC Motor Use Converter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1pc pc
- Supply Capability:
- 8000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords