Variable Frequency Drive 6KV 1250KW VFD

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
100000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Introduction :  


A high tech product with our own intellectual property rights and good performance, for the speed control of 3kv / 6kv/10kv medium voltage motor.


The advantage:

  1. Perfect output waveform, harmonics free

  2. High power factor, high efficiency

  3. Motor speed control & soft start enabled

  4. Reduce operation and maintenance cost

  5. Easy operation

  6. Perfect protection and auto-diagnosis for fault


Typical Application

 

Thermal powerindustry: induced draft fan, blower, dust collection fan, compressor, sewage pump, boiler feed pump etc.


Petrochemical industry: main pumps, submersible pumps, injection pumps, circulating pump, boiler feed pump, halogen water pump, fan, descaling pump, mixer, gas compressors, extrusion machine, etc Mining and metallurgy: slurry pump, induced draft fan, blower,, dust removal fan, descaling pump, centrifugal feed pump, etc Cement manufacturing: water pump, boiler feed pump, halogen water pump, fan, descaling pump, mixer, gas compressors, induced draft fan, preheat tower fan,


pressure blower fan, cooler dust cleaning fan, ball mill for raw material, kiln gas fan, cooler exhausting fan, classifier fan, the main dust collection fan, etc Water supply and wastewater treatment: main line pumps, submersible pumps, injection pumps, circulation pump, sewage pump, cleaning pump, biological processing tower pump Other industry: pulp beater, pumps, rotating machinery, wind turbines, wind tunnel, etc

 

Specification

 

Model

A03/050~
A03/100

A03/100~
A03/175

A03/175 ~A03/220

A03/220~A03/400

A03/220~A03/610

Capacity(kVA)

250~630

630~900

900~1150

1150~2000

2000~3125

Rated output current (A)

50~100

100~175

175~220

220~400

400~610

Motor power (kW)

200~400

400~710

710~900

900~1600

1600~2500

Input frequency

45Hz~55Hz

Rted input voltage

3000V±10%

Input power factor

0.95 (>20%load)

Efficiency

0.96 with rated load

Output frequency

0.5Hz~120Hz

Frequency resolution

0.01Hz

Overload capacity

120% 1 min, 150% immediately

Analogue input

0~10V/4~20mA

Analogue output

0~10V/4~20mA

Acceleration/deceleration time

0.1~3000s

Digital output/input

expanded according to requirement

Ambience temperature

0~40°C

Storage/transport temperature

-40~70°C

Cooling

air cooling

Ambience humidity

<90% without condensation

Altitude

<1000 m

IP class

IP20

Size(mm)(W×H×D)

3300×2480×1200
3900×2480×1200

4900×2480×1200
6000×2580×1200

6000×2580×1300

Weight (kg)

3000 ~5000

5000 ~7300

7300~9200

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Notebook plug in the power adapter lights, but can not open the machine
Put the board under the re-installed, try and then boot. Asked: This is the case of removal, with the battery can boot answer: Then put the battery on the computer, and then use the power splitter to see if you can. If not I do not know, is the computer question to ask: This can be
Q:The Schneider inverter reports the nlp command
Schneider inverter reported nlp ??? main circuit no electricity 1 re-power up 2 connected to the DC reactor terminals PO, PA / + between the short wiring, the main circuit can not be powered
Q:How can a variable speed multi - speed three - phase asynchronous motor be controlled by a frequency converter?
Yes, but it is not necessary, if it is old motor that is another matter, tell you that you can use, but can not be in the frequency conversion process for the pole, this will cause the inverter protection or failure
Q:Yaskawa inverter reported base blockade what is the reason?
Yasukawa compared garbage on the signal board on the small line of poor oxidation, and get like, this is a weak signal, and safety relays connected, do not use high-grade security circuit with a small line short, Yasukawa A 1000 factory is short for a long time after the oxidation of the base blockade
Q:Is the inverter output current proportional to the output torque?
The output voltage of the inverter is proportional to the frequency, which is to keep the motor flux constant, T = KIφ so the motor output torque is proportional to the inverter current.
Q:The inverter flat rate transferred to 29, on the submersible pump to burn the coil ?!
1. submersible pumps are generally the problem, far away from the reflection voltage, the pump insulation breakdown, in particular, to better pump. 2. Distance away, the inverter and pump connection thicker. 3. Then on the output filter.
Q:Taian inverter 3.7KW 380V with 4.0KW 2 pole motor 18000 to 300HZ can it?
The existing Taian inverter 380V3.7KW can bring 4.0KW 2 pole motor, 18000 to 300HZ can also see how you load, It is best to check your wiring tightness and whether the load is stuck. It is recommended to use the N310-4005-S3 this model, such as with the E510-405-H3 better.
Q:Will the motor suddenly stop when the inverter is suddenly powered down?
but there are exceptions, such as head pump, water hammer effect after power failure will make the motor Reversal
Q:Yasukawa inverter reported bb code that is the reason why the base blockade?
This is not a fault! Only after the inverter receives the base block signal, it is not output!
Q:Who knows how the frequency converter works
3. Control circuit Now the basic converter with 16-bit, 32-bit microcontroller or DSP as the control core, in order to achieve full digital control. The frequency converter is the output voltage and frequency adjustable speed control device. The circuit that provides the control signal is called the main control circuit. The control circuit is composed of the following circuits: "operation circuit" of frequency and voltage, "voltage and current detection circuit" of main circuit, and "speed detection circuit" of motor. The control signal of the operation circuit is sent to the "drive circuit" and the "protection circuit" of the inverter and the motor Inverter to take the control mode, that is, speed control, turn control, PID or other means

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range