Variable Frequency Drive 6KV 1250KW VFD

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
100000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Introduction :  


A high tech product with our own intellectual property rights and good performance, for the speed control of 3kv / 6kv/10kv medium voltage motor.


The advantage:

  1. Perfect output waveform, harmonics free

  2. High power factor, high efficiency

  3. Motor speed control & soft start enabled

  4. Reduce operation and maintenance cost

  5. Easy operation

  6. Perfect protection and auto-diagnosis for fault


Typical Application

 

Thermal powerindustry: induced draft fan, blower, dust collection fan, compressor, sewage pump, boiler feed pump etc.


Petrochemical industry: main pumps, submersible pumps, injection pumps, circulating pump, boiler feed pump, halogen water pump, fan, descaling pump, mixer, gas compressors, extrusion machine, etc Mining and metallurgy: slurry pump, induced draft fan, blower,, dust removal fan, descaling pump, centrifugal feed pump, etc Cement manufacturing: water pump, boiler feed pump, halogen water pump, fan, descaling pump, mixer, gas compressors, induced draft fan, preheat tower fan,


pressure blower fan, cooler dust cleaning fan, ball mill for raw material, kiln gas fan, cooler exhausting fan, classifier fan, the main dust collection fan, etc Water supply and wastewater treatment: main line pumps, submersible pumps, injection pumps, circulation pump, sewage pump, cleaning pump, biological processing tower pump Other industry: pulp beater, pumps, rotating machinery, wind turbines, wind tunnel, etc

 

Specification

 

Model

A03/050~
A03/100

A03/100~
A03/175

A03/175 ~A03/220

A03/220~A03/400

A03/220~A03/610

Capacity(kVA)

250~630

630~900

900~1150

1150~2000

2000~3125

Rated output current (A)

50~100

100~175

175~220

220~400

400~610

Motor power (kW)

200~400

400~710

710~900

900~1600

1600~2500

Input frequency

45Hz~55Hz

Rted input voltage

3000V±10%

Input power factor

0.95 (>20%load)

Efficiency

0.96 with rated load

Output frequency

0.5Hz~120Hz

Frequency resolution

0.01Hz

Overload capacity

120% 1 min, 150% immediately

Analogue input

0~10V/4~20mA

Analogue output

0~10V/4~20mA

Acceleration/deceleration time

0.1~3000s

Digital output/input

expanded according to requirement

Ambience temperature

0~40°C

Storage/transport temperature

-40~70°C

Cooling

air cooling

Ambience humidity

<90% without condensation

Altitude

<1000 m

IP class

IP20

Size(mm)(W×H×D)

3300×2480×1200
3900×2480×1200

4900×2480×1200
6000×2580×1200

6000×2580×1300

Weight (kg)

3000 ~5000

5000 ~7300

7300~9200

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:3.7KW inverter with 2.2KW 6-pole motor running to see the inverter shows the current is more than 4A, with the amount of clamp to 2.8A
Probably the error of the clamp meter. 4 more current is correct.
Q:Delta VFD-F frequency converter how to adjust the number of poles
P148 look, this is to correspond to the number of poles of the motor, not to adjust the number of poles of the motor
Q:Is the motor having a variable frequency motor and a variable voltage motor?
It should be no change it is the input / output current is v frequency is its input / output frequency is M / Hz
Q:What is the number of parameters of the motor frequency of the Siemens inverter?
Different types of Siemens frequency changer pole pair parameters different. 6SE70 is p109; The following is the p109 parameter description: P109 * Motor #PolePairs 109 For the synchronous / asynchronous motor input motor pole pairs of the function parameters. If the rated frequency (P107) and rated speed (P108) change, automatic calculation This parameter, if necessary, checks and verifies this parameter. note: - for some of the pulsed encoders (P130 = 11, 12, 15, 16) The maximum number of pole pairs of P109 = 15 can be achieved - P109 must be written when the write function (P060 = 6) is implemented. - Automatic calculation of the pole pair on the motor with regenerative feedback on the rated data Number to be added. Where the function map: 360.2, 361.2, 362.2, 363.2, 364.2   MM4 series is r313, which is calculated by the input rated frequency and rated speed calculated read-only value, must be selected in the p3900 to calculate the correct value. You can also set pole pairs by p314.   S120; G110; G120; G130; G150; S150 with MM4 series.
Q:Laptop computer about electricity no electricity, is the power adapter problem?
This situation is definitely not about what power off, if it is really about electricity no electricity, then your laptop is a one-time shutdown, rather than the screen flashing. I think this situation is more like a laptop screen lamp problem. Is unlikely to be a power problem. The screen flashes from the surface that there may be enough current. If the adapter can not provide enough current for the notebook, then the notebook will be over-current protection, which automatically shut down. You can find an adapter with the same output voltage as your adapter, the output power is greater than or equal to your adapter other adapter, if the situation remains the same, then it is certainly the problem of the lamp. But the inferred will not be a power problem.
Q:Laptop power adapter in the ring is how is it?
Inductance and capacitive shock sound In fact, any inductance and capacitance work will be shocked, but some shocks are large, and some shocks are small, the frequency is not the same, and some sounds harsh, some not harsh, and some ears can not hear the range Inside. Of course, this noise also has a certain standard, in fact, listen carefully, a lot of more power consumption of electronic equipment (tens of watts or more) have a voice. So, as you said to hear the sound is very small, sharp degree is not the same. This do not control, as long as they can endure, the general sound is not great, rest assured that good use of the performance and stability of no effect.
Q:22kw.2 pole fan can use Fuji inverter?
Fan with Fuji? Money more people silly ... no comment ..
Q:How to choose a Siemens inverter for a 5.5KW three-phase motor (2 pole)?
Siemens frequency conversion dedicated input / output filter, reactor, you contact us but smell it, the quality is guaranteed. We look forward to cooperation.
Q:The Schneider inverter reports the nlp command
1, the inverter control circuit with an external 24V power supply, the main circuit did not power 2, PO and PA between the short film can not cause this failure.
Q:380V 2 pole motor can use the inverter?
At the same time, the paint is thick, the best 2 times dipping Wiring with the end of the enameled wire end of the time, to use insulating materials separated better, more insurance

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range