Table 2.3: Technical Parameters of QD200 Series Frequency Inverters

ITEM

SPECIFICATIONS

Main

Input

Rated voltage and frequency

Single-phase 200V class:  200V-240V,50Hz/60Hz

3-phase 400V class:  380V-480V , 50Hz/60Hz

Allowable value of change

Voltage: 380V-15% ~ 480V+10%;  Frequency: ±15%

Main output

Output voltage

Maximum output voltage equals to input voltage

Output frequency

0.5 Hz to 400 Hz

Overload capacity

150% of rated output current for 60s, 200% of rated output current for 2s

Control performance

Modulation mode

3-phase PWM, 2-phase PWM

Control mode

V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving

Setting method of run command

Outer terminal, keyboard panel or serial communication

Setting method of speed command

Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal

Speed setting resolution

Keyboard: 0.1 Hz

Analog setting: 0.05/50Hz (10bit)

Speed control precision

V/f control:±2%

vector control without PG (open loop control): ±0.2%

Speed control range

V/f control 1:40

vector control without PG (open loop control)  1:200

Acceleration and Deceleration

Time

0-3200.0s

switching frequency

1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency

Analog input

Number

2 ways: AI1、AI2

Type

DC voltage or DC current

Maximum input range

AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable

AI2: 0 to 10VDC or PTC probe input receivable

Analog output

Number

1 way: AO1

Type

DC voltage or DC current

Maximum input range

Voltage output: 0 to 10V, Current output: 0/4 to 20mA

logic input

Number

0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2

15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2

note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic)

Type

Source or Sink

Maximum input range

0-24VDC

ITEM

SPECIFICATIONS

logic output

Number

0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C

15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C

pulse signal output

OC,output frequencycurrentoutput、ect other function

relay output

RA-RB-RC, including a NO contact and a NC contact

Maximum switch capacity:

T1A,T1B: 3A at 250VAC, or 4A at 30VDC

T2A,T2B: 2A at 250VAC or 30VDC

Serial communication interface

RS485 interface supports Modbus protocol.

Display

4-digit LED digital display

For display of frequency setting, output frequency, fault code and parameter setting etc.

Environment

Standard

Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.

Altitude

Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m)

Ambient environment

0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating.

Storage: -25 ~ 70°C

Humidity

No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3

Impact strength

15gn for continuous 11ms, In accordance with IEC/EN60068-2-27

Maximum antipollution capacity

Class 2, in accordance with IEC/EN61800-5-1

Structure

Protection level

Top: IP41 (without removing the protective top cover). Other parts: IP20

Cooling Method

Forced Air cooling

Installation method

Wall mounted

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Delta VFD-A frequency converter motor number of poles set
The frequency parameters of the inverter motor are not set, because the inverter will automatically detect the number of pole pairs of the motor during operation, and it will not need to be set.
Q:Asus notebook power adapter how to open
Can only be forced to open the pants and other things wrapped around the line on the line suggested that do not casually demolition
Q:I have a 5.5 kilowatts of 4-pole motor, want to pass through the inverter, slow down to 130 per minute use, eliminating the need for speed,
wo recommendations, the first, the use of vector control of the inverter, you are expected to run the frequency of about 5Hz, this time, ordinary V / F inverter output torque may be small, not necessarily meet the requirements, of course, if it is High-end imported inverter, the problem should be small, with the domestic vector inverter, the frequency can also be full torque output;
Q:The parameters of the inverter is 4, 6 motor can be used
The inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit and so on. The inverter will adjust the voltage and frequency of the output power by the breaking of the internal IGBT, according to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition, the inverter has a lot of protection , Such as overcurrent, overvoltage, overload protection and so on. With the continuous improvement of industrial automation, the inverter has also been a very wide range of applications.
Q:What is the working principle of high voltage electrodes and frequency converters?
The general high and low methods are used in low-power high-voltage motor to do with energy-saving energy. Low-high-mode high-voltage inverter is controlled by a low-voltage inverter, the voltage directly to the motor with a step-up transformer voltage. Low-high mode is also used in low-power high-voltage motor to do with energy-saving energy.
Q:Pump frequency converter instantaneous restart and restart the problem
How the frequency converter works: The frequency converter is a power control device that transforms the power frequency power supply into another frequency by the on-off function of the power semiconductor device. We are now using the inverter is mainly used to pay - straight - cross mode (VVVF frequency conversion or vector control frequency), the first frequency AC power through the rectifier into a DC power supply, and then convert the DC power supply frequency, voltage can be controlled AC power supply to the motor. The circuit of the inverter is usually composed of four parts: rectifier, intermediate DC link, inverter and control. Rectifier part of the three-phase bridge uncontrollable rectifier, inverter part of the IGBT three-phase bridge inverter, and the output for the PWM waveform, the middle of the DC link for the filter, DC energy storage and buffer reactive power.
Q:Laptop warranty period is not over, the power adapter is broken, repair money?
Have to admit that the emergence of Thinkpad x100e, will hit the Internet completely decent, this product is not the name of the Internet, but "ultra-portable notebook", which also shows the x100e relentless and the Internet is willing to belong to similar products. It can be said, x100e is turned out in 2010 turned out professional jet client!
Q:The inverter is running independently
Frequency conversion regulator is the application of frequency conversion technology and microelectronics technology, by changing the motor operating frequency mode to control the AC motor power control equipment. The inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit and so on. The inverter will adjust the voltage and frequency of the output power supply according to the breaking of the internal IGBT, and provide the required power supply voltage according to the actual needs of the motor, so as to achieve the goal of saving energy and speeding.
Q:What is the application of variable frequency speed control?
Generally used in the need for continuous speed control of the place. With the general exchange of motor than its advantages is able to continuously speed. DC motor, although also continuous speed control, but the price is expensive, the volume weight is too large.
Q:380V 2 pole motor can use the inverter?
At the same time, the paint is thick, the best 2 times dipping Wiring with the end of the enameled wire end of the time, to use insulating materials separated better, more insurance

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range