• double layer structure design FRP Oil Storage Tank System 1
  • double layer structure design FRP Oil Storage Tank System 2
  • double layer structure design FRP Oil Storage Tank System 3
  • double layer structure design FRP Oil Storage Tank System 4
  • double layer structure design FRP Oil Storage Tank System 5
double layer structure design FRP Oil Storage Tank

double layer structure design FRP Oil Storage Tank

Supplier:
Lianyungang Zhongfu Lianzhong Composites Group Co.,Ltd.
Ref Price:
get latest price
Loading Port:
Lianyungang
Payment Terms:
TT OR LC
Min Order Qty:
0 set
Supply Capability:
50 set/month
Option:
Volume:20m³-50m³ Diameter:DN2600

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Item specifice

Place of Origin:
Jiangsu,China
Manufacturing standards::
AWWA, ASME, BS, etc.
raw materials:
Resin and glass fiber
color:
Customizable
Surface Treatment:
polish smooth
Applicable medium:
Oil

Sign of The Times

Since the world's first gas station was born in the United States in the early 20th century, the new term "gas station" has been recorded in history. With the rapid development of the automobile industry, gas stations have sprung up like mushrooms. However, with the continuous growth of gas stations, in addition to the rapid development of the automobile industry, there are increasingly strict environmental protection requirements. Environmental pollution caused by oil leakage is an urgent problem to be solved by all countries.

 

At the beginning of the 1960s, Germany pioneered the double-layer tank for storing oil products, and this double-layer tank is made of steel inside and outside, known as SS double-layer

 

In the early 1980s, the American Steel Tank Association launched the SF double tank, which is lined with steel structure, and the outer tank wall is made of FRP and glass fiber reinforced plastic, which effectively resist the erosion from groundwater, microorganisms and soil environment in the buried environment

 

Subsequently, at the end of 1980s, the world's first FF double-layer tank made of BOTH inner and outer FRP materials came out in Los Angeles, USA. This dual-layer FRP storage tank solves the problems existing in previous oil tanks with metal structure, and is well adapted to the corrosion problems caused by the development of biofuels and alternative fuels in recent years. Therefore, it has been widely recognized and supported by laws and regulations, as well as third-party certification organizations such as UL

 

With the development of national economy and the continuous enhancement of people's awareness of environmental protection, laws and regulations related to environmental protection in China are gradually improved. The topic of environmental protection has attracted more and more attention, and the environmental protection of air, water and soil has become the focus of society. Through the "two sessions" during many environmental proposals, let us the whole society is aware of the seriousness of the problem, China has completed the "air ten" revision and "water ten" official release, and the "soil ten" is also coming out.

 

In the eighth article of the "Water Rule", it is required in the prevention and control of groundwater pollution that all underground oil tanks of gas stations should be upgraded to double tanks or anti-seepage ponds should be set up before the end of 2017.

 

Double wall FRP oil storage tank features:

As fuel and chemical containing liquids stored in underground steel tanks around the world have become more and more erosive over the past few decades, a large number of markets are moving towards using FRP tanks in addition to coating the inner surfaces of existing steel tanks. Because the permeability and compressive strength, FRP tanks from single-walled incline to double wall, both inside and outside double using enhanced glass fiber materials, has a long service life, corrosion resistance, prevent conductive, light weight, free maintenance, as well as good seismic performance, production process mainly has the short cut fiber injection method, the centrifugal casting method, winding molding process, such as double even the more than 30 years of glass fiber reinforced plastic production Product design and manufacturing experience, quality assurance let you rest assured.

 

Comparison table of characteristics of various double - wall storage tanks

F/F double-wall tank

S/S double-wall tank

S/F double-wall tank

The inner and outer walls are made of FRP

The inner and outer walls are steel structural layers

Inner steel, outer FRP material

Never rust

Easy to rust

The inner wall rusts easily

Thick structure wall, high external pressure strength

Thick structure wall, high external pressure strength

Easy to scratch, peel or rupture

External wall leakage can be measured by positive pressure

External wall leakage can be measured by positive pressure

The outer wall is not structural layer, can not be positive pressure leakage test

No cathodic protection is required

External wall leakage can be measured by positive pressure

The outer wall is not structural layer, can not be positive pressure leakage test

High voltage pinhole detection is not required

Unable to do high voltage pinhole detection

Need 35kV high voltage pinhole detection

If found leakage can be repaired

Unable to do high voltage pinhole detection

Need 35kV high voltage pinhole detection

The tank is light, easy to construct and cost effective

Unable to do high voltage pinhole detection

Need 35kV high voltage pinhole detection

 

LZFRP production of FRP double way oil tank adopts double structure design, in the interlayer between the inner and outer wall can be installed within 24 hours of continuous monitoring system, both inside and outside wall leakage, mezzanine can be automatic induction and alarm, instant repair, put an end to the oil cause pollution to soil and underground water, in line with international environmental requirements:

1.Double - wall tank is a continuous leakage monitoring system when damaged.

2.If the inner wall of the double-wall tank is damaged or leaked, the detected liquid level in the interlayer between the inner and outer walls will drop.

3.If the outer wall of the double-wall tank is damaged or leaked, the detected liquid level in the interlayer between the inner and outer walls will also decrease.

4.If the groundwater level is higher than the detected liquid level in the sandwich and the outer wall is damaged or leaked, the detected liquid level in the sandwich will rise.

 

 

 

 

 

 

 

FRP double wall tank parameters table:

Item

Volume m³

20

25

30

35

40

45

50

Tank length (mm)

4600

5800

2600

7900

8900

10000

11000

Nominal diameter (mm)

2600

Filling coefficient

0.9

Manhole diameter (mm)

600

Design pressure (MPa)

0.172

Inner surface resistivity (Ω)

109Ω

Inner wall volume resistivity (Ω)

108Ω

Leakage detection resolution (L/h)

0.8

Service life (years)

50

Warranty Period (year)

30

20m³FRP double wall tank

 


25m³FRP double wall tank


 

30m³FRP double wall tank


35m³FRP double wall tank

  

40m³FRP double wall tank

 

45m³FRP double wall tank

 

 

50m³FRP double wall tank

 

 

Quality assurance

I. Comprehensive and abundant testing equipment:

LZFRP has the industry first-class physical and chemical laboratory, have all kinds of testing equipment more than 100 sets, with the industry's only microcomputer control pipe mechanical properties testing machine, Germany imports of magnetic thickness gauge, thread, differential scanning calorimeter single parameter tester, hydrostatic pressure testing machine, island ferry universal material testing machine, Instron material fatigue testing machine, the gold Like microscope, according to API, ASTM, ISO, BS and domestic standards for raw material detection and physical properties of the product inspection, such as internal pressure blasting test, long-term hydrostatic pressure failure test, cyclic pressure test, stiffness test, DSC differential thermal analysis, chemical resistance test, material mechanics test and a series of tests.

 

II.Enforce standards and specifications:

 GB/T 50156-2012 Code for design and construction of automobile refueling and filling stations

 GB/T 1410-2006 Test method for volume and surface resistivity of materials

 GB/T 13348-2009 Liquid petroleum products electrostatic safety code

 GB/T 50650-2011 lightning protection design code for petrochemical installations

 SH 3097-2000 Code for electrostatic grounding design in petrochemical industry

 Db11/588-2008 Technical specification for leakage prevention of buried tank

 JB/T 4731-2005 steel horizontal container

 SH/T 3177-2015 Engineering specification for buried glass fiber reinforced plastic double layer oil tank for gas station

 UL 1316-2006 Glass-Fiber-Reinforced Plastic Underground Storage Tanks for Petroleum Products, Alcohols, and Alcohol-Gasoline Mixtures


Q:Tank leakage how to do, glass fiber reinforced plastic repair, tank maintenance, after-sales service?
FRP pipe installation, leakage of glass fiber reinforced plastic pipe. FRP interface.
Q:Can formaldehyde be used in FRP tanks?
After investigation, vinyl, furan, phenolic and epoxy FRP are resistant to formaldehyde, the temperature is less than 60 degrees.
Q:There is a storage tank, which was originally village glue, and now prepared to glue on the basis of the village glass fiber reinforced plastic anti-corrosion, can?
No, it is decided by the characteristic of FRP. It can not stick.
Q:20 cubic meter FRP double deck tank price
70 thousand, fiberglass tanks and steel cladding tanks are quite different.
Q:Why leakage occurs during the use of FRP tanks?
Poor production, including lining defects, inappropriate selection, low strength and so on
Q:Is fiberglass tank good for gasoline? Would you like to use fiberglass jars to store gasoline in the ground?
Basically, most glass insulated septic tanks or tanks can now produce resistant FRP tanks.
Q:What's so special about the softened steel water tank?
The whole process is automatic. Only salt is added on a regular basis without manual intervention.
Q:What matters should be paid attention to when cleaning and maintaining FRP tanks?
FRP tanks often in the course of cleaning and maintenance, Guangzhou Weibo FRP to introduce several items in the cleaning of note: 1. into the glass steel tank maintenance, should close all the inlet valve, emptying and cleaning tank, after testing confirmed that no toxic gas tank, not hypoxia in order to enter into the tank, the tank should wear soft soled shoes, tied the safety belt and the safety belt on the other end attached to the tank top, tank ventilation attention. Into the tank operation, there must be personnel outside the tank monitoring.
Q:How can the 800*1200 stainless steel tank be protected from corrosion?
Before construction, in order to ensure the effect of corrosion protection, we have to do another step, that is, to remove stainless steel tank surface rust, oil quality, old paint film, and so on, and some will affect the quality of construction debris.After all this is taken care of, we can really paint. But we must pay attention to, at room temperature, we have to paint every 4 hours to ensure the effect and quality of paint.
Q:Can FRP tanks withstand industrial hydrochloric acid?
Small to a few cubic meters, large to dozens of cubic meters, you can do.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords