• Cutting Sewage Centrifugal Water   Pumps System 1
  • Cutting Sewage Centrifugal Water   Pumps System 2
  • Cutting Sewage Centrifugal Water   Pumps System 3
Cutting Sewage Centrifugal Water   Pumps

Cutting Sewage Centrifugal Water Pumps

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Product Introduction of WQ series Sewage Submersible Pump

WQ series submersible sewage pump is mainly used for municipal work, industrial building, hotels, hospitals, civil air defense, mines, etc. It can be widely used in transfer waste water, rainwater and living water etc. which contains solid grains and various long fibers CNBM WQ series sewage submersible pump have many advantages, such as, hi-efficiency, circumvolution proof, blockage free, auto-coupling, hi-reliability and auto-control, etc.

 

2. Technical Performance of WQ series Sewage Submersible Pump

Discharge diameter: 50~600 mm

Capacity: 10~8000m³/h

Head: 5~60m

Power: 1.5~315kw

Diameter of pass solids: 20~145mm

 

3. Operation Condition of WQ Series Sewage Submersible Pump 

1). Rated Voltage: 380V(660V), Frequency: 50Hz, 3-phase AC.

2). Temperature of medium under 40ºC.

3). PH value: 4~10.

4). Volume ratio of solid in medium below 2%.

5). Density of medium should be lower than 12000kg/m³.

 

4. Structure Characteristic of WQ Series Sewage Submersible Pump

WQ series submersible sewage pump is equipped with status indicator and protection device to ensure for pump safe and reliable operating.

1). The unique cable airproof is adopted, avoid leakage of cable.

2).  Heat protector in stator assure of operating life of the motor.

3).  The pump adopts outer recycling cooling design with motor power more than 18.5kw, which can keep the pump operating safely under the lowest water level.

4).  A floating switch is installed at the bottom of motor chamber to protect the mechanical seal in the motor side.

5).  The oil-water probe is installed at the up end of the oil chamber between pump and motor that can protect the mechanical seal in the side. If leakage occurs, the system will signalize and start protection.

6).  Adopt perfect mechanical seal, the sealing material adopt tungsten carbide, silicon carbide and hard metal alloy, which can prevent the water from entering into the motor, and keep the operating reliable and safety.

7).  The auxiliary impeller can balance the pressure outside of the mechanical seal, prevent the water entering into the oil chamber and prolong the life of the motor.

8).  Unique impeller design, wide passage allow large solid and long fiber passing through freely, it features non-clog, convolve-proof and good passing ability.

9).  The changeable wearing ring is installed between the impeller and the volute to keep the optimum operation conditions.

 

5. Impeller Design Characteristics of WQ Series Sewage Submersible Pump

For the feculence pass freely, it must be widen the flowing passage of impeller, for the big pump, can used for double-vane, or three-vane, for the small pump, it used for single(double) flowing passage, like a bent pipe has same section, it has a good passing characteristic, avoid stop, convolve caused by slowing current possibly. The especially flowing passage of impeller, cooperate with logical volute, made the paper, soft goods, garbage bag and other material in sewage can passing freely and the pump have no vibration in the course of running-in and load through the impeller balance between dynamic and static state.

 

6. FAQ

1). Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2). Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3). How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

4)  Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

5) Do you have self-priming pumps?

Yes, our product portfolio also includes two ranges of self-priming pumps: self-priming electric pumps and self-priming side channel pumps.

6) Is it really necessary to fit a bleed valve for the boxes?

It is always best to have a bleed valve as the gas produced by the fermenting sewage is potentially hazardous.Cutting Sewage Centrifugal Water   Pumps

Cutting Sewage Centrifugal Water   Pumps


Q:Is the diaphragm pump and the drain pump one?
Therefore, the need to play a liquid discharge pump, if the medium is corrosive liquid, high viscosity, volatile, flammable, highly toxic liquid, you can choose diaphragm pump. Conversely, the general liquid, there is no special requirements, you can use the general centrifugal pump to reduce costs.
Q:Piston filling and peristaltic pump filling which precision is high?
First of all, we should know the working principle of each, and analyze the accuracy from the principle, this problem is very important. Piston filling, such as the injection of drugs that we have been ill, the accuracy of the piston pump depends on the accuracy of the motor and the area of the unit cross section
Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q:Troubleshooting of diaphragm pump
In the application of the pump, these conditions are likely to encounter. Each situation can be divided into several possible reasons. This guide lists the causes of failures and gives appropriate corrective maintenance measures. The meaning of all the specific terms in the guide is listed later.Air valves - copper or stainless steel valves are bolted to the center of the pump by four bolts.The piston aluminum cylinder is enclosed in the air valve to control the gas flow.Cavitation - because the pump inlet for the amount of fluid to reduce or lack, the pump discharge is less than the amount of quantitative. In fact, the fluid chamber is full of fluid before it is discharged.Static pressure drop - the inlet pressure from the pump centerline to the free point - the inlet is measured in pounds, including the specific gravity and velocity of the fluid.
Q:5 floor water pressure is too low, what kind of water pump is better?
Installed pump flow, lift did not meet the requirements, this will need to re type selection, calculation;
Q:Water pump outlet valve sequence
Design specifications detailed manual instructions, divided into two cases:1, pump water first check valve, suitable for small caliber pipeline, gate valve to protect the non-return valve, not damage function;2, pump water out of the first gate valve, check valve for large diameter pipe, at this point valve easy to open and close;The setting of the check valve is mainly to avoid the high reverse speed of the pump and the condition of the submerged pump house. Set in the suction port of the pump, then stop the pump water flow will still affect the pump. In addition, the pump suction should try to avoid installing too many pipe fittings, so that the pump can maintain sufficient cavitation margin.
Q:The difference between submersible pumps and centrifugal pumpsWhat's the difference between the two? What is applicable and what?
High speed rotating impeller blade drives the liquid to rotate, and the liquid is thrown out so as to achieve the purpose of conveying. There are many medium for transportation, such as oil, water, chemicals and so on. The pump shaft and the motor shaft are of the same shaft, the pump and the motor are made into an integral body and immersed in water. The medium of transportation is water.
Q:Fire hydrant pump button, under what circumstances do not need to install?
General high voltage system, when normal, use small pump steady pressure.Fire hydrant button lifting pump is one of the multiple pumping methods, and it is an important link of reliable operation of the system.
Q:How to select metering pump head?
The main index affecting the selection of the pump head is the composition of the medium to be transported and added, as well as the pressure and the temperature of the external environment
Q:Do you have a suction pump higher than 9 meters?
Since the atmospheric pressure has been basically determined, the theoretical suction degree of the pump is more than 10 meters.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords