Oil-filled Submersible Pump

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Product introduction:
QYOil-filled submersible pump consists of pump, mechanical seal and motor. Pump is at the bottom part of pump, which is adopted centrifugal impeller. Motor which is triphase is at the upper part of pump and seal is used where pump and motor combine, which is a kind of double end mechanical seal"0"rings are applied to all static joints.
Axial flow impeller design can meet customer demand for big flow

Application:
This series pump because of wide range of flow and head, is extensively used for electrical irrigation, forest water spraying, pumping water from well, water tower deliver and urban construction water supply and discharge for farms, villages, industrial and mining enterprise.

Work Conditions:
The pump can work properly and continuously under following operational conditions:
1.Medium is not corrosive. Sand contents should be max. 0.10% by volume and granular size should be max.0.20mm.
2.Medium temperature shouldn’t be over 40°C and PH should be 6.5-8.5.
3.The pumps should be operated within rated head.
4.The pumps should be fully submerged into water with depth of less than 3m and max. The pump should be min. 0.5m over (he water bottom and not be inserted into sludge.
5.Power frequency should be 50Hz,three-phase vollage 380V.and voltage fluctuation should be 0.9-1.1 limes than the rated.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system?
Valve control system is generally used for open systems, through the proportional valve or servo valve flow changes to control the motor or cylinder actuator action. The advantages of the system are energy saving, heat generation, and control accuracy. The disadvantage is that the system is complex and the cost is higher.
Q:Harm of air pump and pump
Minimum starting current when centrifugal pump of such a small impact on the grid but long closed operation will make the liquid in the pump to the pump overheating temperature is too high will lead to the problem of the seal to a certain temperature will cause deterioration of oil bearing bearing caused by excessive wear and even bite dead
Q:Pump operator's responsibility Sharing the rules, responsibilities, etc..
7., master the knowledge of concrete mix ratio, strictly forbid to add water to the pump at will.8., concrete mixing and workability, gravel diameter is too large, effectively refuse to pump.9. when the delivery pump fails, it can analyze the cause and quickly eliminate the trouble.10. pump complete, you must clean the pump body and pressure pipe residual.11. complete other temporary work assigned by the leader.
Q:Fire pump control cabinet There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, and two outdoor pumps
Indoor fire hydrant pump in addition to remote direct Kai, there are modules to start function, that is, on the cabinet to add control module, bus linkage pump, but also fire hydrant button, direct pumping function, a total of three functions.Outdoor fire hydrant pump in addition to remote direct Kai, but also an electric contact pressure meter detection system, water pressure from the pump and high pressure pump stop function.
Q:Is the diaphragm pump and the drain pump one?
First of all, there's something wrong with your concept.Diaphragm pump is in accordance with the way the pump classification, drain pump is in accordance with the use of pumps classification.
Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
Q:Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
The power of axial flow pump decreases with the increase of flow rate, and it is a steep curve, so the centrifugal pump starts with an open valve.
Q:What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
The unified corrosion resistant design of bronze impeller improves the corrosion resistance of the pump, and the stainless steel material is more suitable for more severe applications;
Q:What should be used to pay attention to the use of mechanical pumps?
When opening the pump, first close the outlet valve, lift the pressure, then open the outlet valve again, pay attention to the flow of the motor.
Q:How many square cables does the submersible pump for 7.5KW need?
According to current I=13A, it is estimated that the cable is less than 10 square meters, so the cable cross section can be calculated at the ampacity of 5A per square meter. The square section of the cable is =13/5=2.6 square. According to the specifications series, optional 2.5 square aluminum cables. When the cable is longer, it is safer to choose 4 square aluminum cables.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range