SLL type vertical single stage single suction volute casing pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
500 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

SLL series large vertical single-stage single-suction centrifugal pump is a brand-new single-stage single-suction centrifugal pump developed on the basis of the years' scientific research achievements and production experience, upon the market demand and by absorbing the technical superiorities of the same ones both at home and abroad and strictly following the latest national standard.
SLL series pump comes as a large aperture vertical singlestage single-suction centrifugal pump and is applicable for the water supply and drainage system of large thermal power pants, the industrial and city water supply and drainage system,the water supply and drainage project in the farmland construction,remote water transportation and equipment completion
to transport pure water or other liquids of the physical and chemical natures similar to those of pure water, with the temperature of the medium not over 50℃
Performance range of SLL series pump, the flow range is 2800-21600m³ /h,the head range is 17~70m, the inlet diameter is 600~1200mm,available with 18 kinds of products of the basic norms in 6 apertures and different performance demands can be met with by means of cutting the outer diameter of the impeller or regulating the speed of the motor.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How many kilograms of water pump are there in the automatic washing machine on the market?
Suitable for supporting high pressure sprayer, portable car washer. Water pump with overflow circuit. And comes with pressure switch, overflow switch double insurance
Q:How about the depreciation of vacuum pumps?
(three) appliances, tools, furniture and so on related to the production and operation activities, for 5 years;(four) aircraft, trains, ships and other means of transport for 4 years;
Q:What is the series of pumps? What's the difference between a unipolar and a multistage?
A single-stage pump is a pump with only one impeller. 2, a multistage pump is a pump with two or more impellers. The multistage pump can increase the pressure and lift the head higher. Level 1 means a booster impeller.
Q:The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
That is impossible. The suction height of the pump is caused by the centrifugal force of the vacuum. The water is sucked into the vacuum
Q:Do you have a suction pump higher than 9 meters?
Since the atmospheric pressure has been basically determined, the theoretical suction degree of the pump is more than 10 meters.
Q:Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Q:What is the distance between the pump and the wall?
What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.
Q:What is the pump lift voltage? And how to suppress the pumping voltage rise?
The reverse voltage and torque electric torque instead, and the motor has strong braking torque, forcing the rotor quickly stopped, but usually AC-DC-AC converter is the main power AC/DC rectifier circuit is irreversible, and therefore can not return to the power grid, resulting in the main circuit of the capacitor voltage increases two that is called the pump voltage.
Q:Fire pump and shower pump flow head selection, high resolution.
3, larger than 25000, the minimum water consumption of indoor fire hydrant is 20L/s4, the minimum water consumption is the flow of a fire hydrant.
Q:What is the lift of diaphragm pump?
Diaphragm pump lift is different from the centrifugal pump, refers to the diaphragm pump can raise the height of water, the unit is meters water column. Lift depends on the size of the outlet pressure, the pressure per kilogram is equivalent to 10 meters height

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range