Product Description:


1.220V Single Phase Variable Frequency Drive 2.2KW
2.Advanced control technology
3.Easy to operate

    220V Single  Phase Variable Frequency Drive 2.2KW




CNBM  frequency  inverter is a high-quality, multi-function,

low-noise variable frequency drive which is designed, developed and manufactured according to international standards.

It can meet different needs of industrial conditions.

The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse.



Product Name:CMAX-VCG15/P18.5T3 ~ CMAX-VCG18.5/P22T3





Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.


Plastic: extruder, hauling machine, decorating machine, etc.


Pharmacy: mixer, roaster, etc.


Woodworking: engraving machine, sander, veneer peeling lathe, etc.


Papermaking: single type papermaking machine, etc.


Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.


Printing: cloth-washing machine, dye vat, etc.


Cement: feeder, air blower, rotary furnace, mixer, crusher, etc


Fan and pump: kinds of fans, blowers and pumps







Input voltage


Input frequency



Output voltage

0~input voltage

Output frequency


Peripheral interface characteristics

Programmable digital input

4 switch input, 1 high-speed impulse input

Programmable analog input

AI1: 0~10V input

AI2: 0~10V input or 0~20mA input,

Programmable open collector


2 Output

(3.7kW and above: 1 Open collector output)

Relay Output

1 Output (3.7kW and above: 2 Relay output)

Analog output

2 Output, one is 0~10V,

another is 0~20mA or 0~10V


Display:5-digit 8-section LED (Red), 2 indicators; parameter setting: 8 keys (including multi-function hot key ), 1 potentiometer

Technical performance characteristics

Control mode

All digital space voltage vector SVPWM algorism

Overload capacity

G purpose: 150% rated current 60s

P purpose: 120% rated current 60s

Speed ratio

1: 100

Carrier frequency


Torque compensation

Linear, multi-point, 1.3th power, 1.7th  power, 2.0th power reduced torque; Compensation voltage range: automatic compensation and manual compensation 0.1~10%

Automatic voltage adjustment

It can automatically maintain output voltage constant when grid voltage fluctuates.

Automatic current adjustment

When the current is over current limit, under clocking automatically limits output current.

Function characteristics

Frequency setting mode

Keypad digital analog input, keypad potentiometer, impulse frequency, communication, multi-step speed and simple PLC, PID setting and so on, switch-over of setting modes.

Simple PLC,

multi-step speed control

16-step speed control

Special function

Traverse control, length control, time control


User-defined multi-function hot key

Protection function

Over-current, Over voltage, under-voltage, over-heat, phase failure, over-load and motor over-load

Working condition

Installation site

Indoor, altitude of less than 1km, dust free, non-corrosive gases, no direct sunlight

Application environment

-10°C~+40°C, 20~90%RH (no dew)


Less than 0.5g

Storage temperature


Installation type

Wall-mounted type, floor cabinet type

Cooling mode

Air-forced cooling



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Why does harmonic generator produce harmonic? What's his working principle?
Harmonic generation mechanism of inverter inputThe main circuit of inverter is composed of AC-DC-AC, external input 380V/50Hz power supply through the three-phase bridge rectifier, a DC voltage, AC voltage by the capacitor filter and high power transistor switching element for variable frequency inverter. In the rectifying circuit, the input current waveform is a rectangular wave irregular waveform, according to Fu Liye series is decomposed into fundamental and harmonics, the harmonic frequency is usually 6N + 1 harmonic, the harmonic interference input power supply system. If the reactance of the supply side is sufficiently small and the commutation overlap angle can be neglected, then the n order harmonic is the 1/n of the fundamental current.
Q:What is the over-current of the inverter?
The reason of the frequency converter itself: 1, parameter setting problem: for example, the acceleration time is too short, the PID regulator's proportion P, the integral time I parameter is unreasonable, the overshoot is too big, causes the frequency changer output current oscillation. 2 、 frequency converter hardware problem:
Q:What is the difference between frequency converter and UPS?
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the power supply frequency of the motor to control AC motor power control equipment. The frequency converter is mainly composed of rectifier (AC DC converter), filter, inverter (DC AC converter), brake unit, drive unit, detection unit, micro processing unit and so on. Inverter by internal IGBT drive voltage and frequency off to adjust the output power, the power supply voltage required to provide according to the actual needs of the motor, so as to achieve the purpose of speed, energy saving, in addition, there are a lot of protection drive, such as over-current, over-voltage, overload protection and so on. With the continuous improvement of the degree of industrial automation, inverter has also been widely used.UPS is an uninterruptible power supply, including an energy storage device, a rectifier, inverter as the main component of the regulator, frequency stabilized AC power supply. The main use of battery energy storage power supply device to provide uninterrupted computer / server, storage equipment, network equipment, computer communication network system and industrial control system, need continuous operation of industrial equipment in power outages. When the power input is normal, UPS electric voltage supplied to the load, the UPS is an AC electric regulator, it is also to the storage device such as a battery charging; when the power interruption (outage), UPS immediately to the storage device (such as batteries or fly wheel the electric energy storage system), continue to supply alternating current to the load by the method of inverse transformation, the load to maintain normal working and protect the load of software and hardware is not damaged.
Q:What is the traction frequency converter for electric cars?
Optimal energy utilization.The optimal utilization of energy is another basic requirement of electric vehicle, the control system can be as much as possible the use of energy, including the use of overheating and regenerative braking energy, make full use of limited energy. Ability feedback can implement this function. It includes two kinds of vehicle braking capability feedback and vehicle coasting ability feedback. In our state, the drive motor according to the operation of the generator, the vehicle kinetic energy into electricity, can play 3 roles: auxiliary braking; energy recovery to the power battery, thereby prolonging the vehicle mileage; in vehicle heating demand, can directly use this energy heating.
Q:What are the possible causes of frequency hopping overload?
Because the overload is judged only by the current, it will happen at the start, stop, acceleration and deceleration, and constant speed operation. Moreover, the current and the asynchronous motor difference are inseparable, so the following conditions can be used for analysis and reference:
Q:Where is the frequency converter used?
From the industry application: 1, chemical, petroleum, electric power, municipal, mining, cement, water treatment and other industries, the main use of 380V/690V/6-10kv inverter, these industries have a large fan pump power, the original AC operation, high energy consumption, the use of inverter speed regulation can be obtained after large energy saving, so it is the the main users of the main high power converter
Q:Surface grinder can add frequency converter, what are the advantages and disadvantages?
SAJ inverter in the industry's specific applicationZhejiang Kanmen machine tool factory mainly produces all kinds of economic type simple NC machine, due to the higher failure rate of electromagnetic clutch speed regulation, realize VVVF system has more advantages, so using VVVF inverter to achieve the three. The details are as follows:
Q:What is the upper and lower limit of the environmental temperature to ensure the normal operation of the inverter?
General environment temperature: inverter is an electronic device, containing electronic components, electrolytic capacitors, etc., so the temperature has a greater impact on its life. The environment of general inverter operating temperature of ~+50 DEG C - General requirements, if it can reduce the operation temperature of inverter, prolongs the service life of the transducer, stable performance. So heat dissipation is very important.
Q:How about the quality of ABB converter?
The quality is very good.Frequency converter (Variable-frequency, Drive, VFD) is the application of frequency conversion technology and microelectronics technology, by changing the power supply frequency of the motor to control AC motor power control equipment. The frequency converter is mainly composed of rectifier (AC DC converter), filter, inverter (DC AC converter), brake unit, drive unit, detection unit, micro processing unit and so on.
Q:Which country invented the inverter?
PC power supply using bridge rectifier, capacitor filter circuit will make the traditional AC input current waveform distortion, inject a large amount of high harmonics to the power grid, so the grid side power factor is not high, only about 0.6, and caused serious harmonic pollution and interference on the power grid and other electrical equipment. As early as the early 80s, the harm caused by higher harmonic currents caused by such devices has attracted much attention. In 1982, the International Electrotechnical Commission formulated the IEC55 2 specification (revised standard harmonic limit later is IEC1000 - 3 - 2), the power electronic technology, many workers began to harmonic filtering and power factor correction (PFC) technology research. The introduction of PFC circuit in electronic power supply can greatly improve the utilization efficiency of electric energy.

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range