China Best Selling VFD Frequency Drive 3 phase 220V 380V

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
100000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

1.220V Single Phase Variable Frequency Drive 2.2KW
2.Advanced control technology
3.Easy to operate

    220V Single  Phase Variable Frequency Drive 2.2KW

 

General

 

CNBM  frequency  inverter is a high-quality, multi-function,

low-noise variable frequency drive which is designed, developed and manufactured according to international standards.

It can meet different needs of industrial conditions.

The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse.

 

 

Product Name:CMAX-VCG15/P18.5T3 ~ CMAX-VCG18.5/P22T3

 

Application

 

 

Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.

 

Plastic: extruder, hauling machine, decorating machine, etc.

 

Pharmacy: mixer, roaster, etc.

 

Woodworking: engraving machine, sander, veneer peeling lathe, etc.

 

Papermaking: single type papermaking machine, etc.

 

Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.

 

Printing: cloth-washing machine, dye vat, etc.

 

Cement: feeder, air blower, rotary furnace, mixer, crusher, etc

 

Fan and pump: kinds of fans, blowers and pumps

 

 

Specification

Item

Specification

Input

Input voltage

220/380V±15%

Input frequency

47~63Hz

Output

Output voltage

0~input voltage

Output frequency

0~600Hz

Peripheral interface characteristics

Programmable digital input

4 switch input, 1 high-speed impulse input

Programmable analog input

AI1: 0~10V input

AI2: 0~10V input or 0~20mA input,

Programmable open collector

output

2 Output

(3.7kW and above: 1 Open collector output)

Relay Output

1 Output (3.7kW and above: 2 Relay output)

Analog output

2 Output, one is 0~10V,

another is 0~20mA or 0~10V

Keypad

Display:5-digit 8-section LED (Red), 2 indicators; parameter setting: 8 keys (including multi-function hot key ), 1 potentiometer

Technical performance characteristics

Control mode

All digital space voltage vector SVPWM algorism

Overload capacity

G purpose: 150% rated current 60s

P purpose: 120% rated current 60s

Speed ratio

1: 100

Carrier frequency

1.0~10.0kHz

Torque compensation

Linear, multi-point, 1.3th power, 1.7th  power, 2.0th power reduced torque; Compensation voltage range: automatic compensation and manual compensation 0.1~10%

Automatic voltage adjustment

It can automatically maintain output voltage constant when grid voltage fluctuates.

Automatic current adjustment

When the current is over current limit, under clocking automatically limits output current.

Function characteristics

Frequency setting mode

Keypad digital analog input, keypad potentiometer, impulse frequency, communication, multi-step speed and simple PLC, PID setting and so on, switch-over of setting modes.

Simple PLC,

multi-step speed control

16-step speed control

Special function

Traverse control, length control, time control

QUICK/JOG key

User-defined multi-function hot key

Protection function

Over-current, Over voltage, under-voltage, over-heat, phase failure, over-load and motor over-load

Working condition

Installation site

Indoor, altitude of less than 1km, dust free, non-corrosive gases, no direct sunlight

Application environment

-10°C~+40°C, 20~90%RH (no dew)

Vibration

Less than 0.5g

Storage temperature

-25°C~+65°C

Installation type

Wall-mounted type, floor cabinet type

Cooling mode

Air-forced cooling

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How can I control the frequency converter with a computer?
Variable frequency speed control has been applied in the industrial field as the main means of AC motor speed control is very extensive, it has a wide speed range, steady speed and high precision fast dynamic response for a wide range of technical performance and reliable operation, has gradually replaced the DC motor speed control system. There are three main control modes of inverter: 1. through inverter panel operation, that is through the operation panel to change the output frequency and other operating parameters; 2. in the frequency converter analog input 0 ~ 10V or 4 ~ 20mA signal, by changing the size of input analog control of inverter output frequency converter; 3. through communication port (for RS485 control). The first method is generally used for manual adjustment and parameter setting on the spot, and the latter two are mostly used for automatic adjustment and remote control.
Q:What is frequency conversion? What is the function of frequency converter?
Theoretically, the inverter can be used in all mechanical equipment with electric motor, the motor starts, 5-6 times higher than the rated current, will not only affect the motor service life and consume more power. In the design of the system in the motor selection will leave some margin, the speed of the motor is fixed the same, but in actual use, sometimes running at low or high speed, so the frequency transformation is very necessary. Transducer can realize soft starting and compensating power factor of motor
Q:What are the contents of frequency converter maintenance?
Regular maintenanceClean air filter, cooling air duct and interior dust. Check whether the screws, bolts and plug are loose, the input and output reactor ground and interphase resistance is short circuit, the normal should be more than tens of megabytes of europe. The conductor and insulator are corrosion phenomenon, if in time to wipe clean with alcohol. If the conditions permit, use the oscilloscope to measure the stability of the switching power supply output voltage, such as: 5V, 12V, 15V, 24V and other voltage. Is there any distortion in the square wave of the measuring circuit?. Is the UVW phase waveform sinusoidal?. The contact of a contactor whether traces the strike, serious to change with the same or greater than the original capacity of new products; confirm the correctness of the control voltage, the order of protection test; confirm that there is no abnormal loop protection; confirm the balance of the inverter output voltage in a single run time.
Q:What is the difference between SIEMENS inverter and built-in filter?
SIEMENS built-in filter optional three. Class a EMC filter. B class EMC filter. LC/ sine filter.Power 110KW to 250KW converter, optional external or built-in level a filter,The power 7.5KW to 15Kw converter, in addition to additional B class EMC filter, can be equipped with a class EMC filter.The LC/ sinusoidal filter can effectively suppress the rise of voltage and capacitance charge / discharge current in the variable frequency drive. But there are many restrictions: only V/F is allowed. FCC control mode. To comply with the 15% drop capacity, the output frequency limit is 150HZ, and only allowed to operate at the 4KHZ pulse frequency. In operation and debugging, the LC sinusoidal filter must be connected to the motor.
Q:I would like to ask vector control of the frequency converter, how the motor does not turn. What parameters are set up
Because the dynamic mathematical model of induction motor is a high order, nonlinear and strong coupling multivariable system. In the 70s of last century, SIEMENS Engineer F.Blaschke first proposed asynchronous motor vector control theory to solve the AC motor torque control problem. The basic principle of vector control is achieved through the measurement and control of induction motor stator current vector, according to the principle of field orientation respectively, excitation current and torque current of induction motor control, so as to achieve the purpose of controlling the torque of asynchronous motor. In particular the stator current vector is decomposed into a component of current magnetic field (excitation current) and the torque producing current component (torque) to control respectively, and at the same time to control the amplitude and phase of the two components, namely the control of stator current vector, so that this control method is called vector control mode. In brief, the vector control is to decouple the magnetic flux and the torque, which is beneficial to design the regulator of both of them, so as to realize the high speed control of the AC motor. There are vector control methods based on slip frequency control, speed sensorless vector control method and vector control method with speed sensor. Thus, a three-phase induction motor can be equivalent to a DC motor to control, so as to obtain the same static and dynamic performance as the DC speed regulating system. Vector control algorithm has been widely used in Siemens, AB, GE, Fuji and other international large company frequency converter.
Q:Why does the frequency converter cause interference?
Shielded interference source: shielded interference source is an effective way to suppress interference. Usually the inverter itself with iron shielding, can not let the leaked electromagnetic interference, but the output line frequency converter is best to use steel shielding, in particular to an external signal (4~20mA signal output from the controller) control of inverter, the control signal line is as short as possible (usually less than 20m), and must use the shielded twisted pair and the main power line and the control line (AC380) and (AC220V) completely separated. In addition, the circuit of electronic sensitive equipment in the system also adopts shielded twisted pair, especially the pressure signal. All signal lines in the system must not be placed in the same pipe or slot as the main electrical line and control line. To make the shield effective, the shield must be grounded reliably.
Q:The difference between soft starter and converter
The soft starter is just a thyristor pressure regulating device is simple to start the motor, the motor speed can not be normal, low price; inverter is the AC power supply voltage and frequency, can IGBT chopper can be used to start the motor, can also be normal speed, the price is relatively expensive
Q:What's the frequency converter for? What does it look like?
AC motor stepless speed regulation can save energy in some occasionsThe appearance of the basic manufacturers are one of the same
Q:What does the RUN key on the inverter mean? How do you use it?
There are two conditions on the panel of the converter. There is one panel with FWD (positive turn), REV (reverse), and STOP (stop). There is also a panel, only the positive turn, just write RUN.
Q:What role does input and output reactor play?
Enter the reactor to suppress the surge voltage and surge current protection, frequency converter, and prolong its service life and prevent the harmonic interference, at the same time as the speed control inverter adopts frequency conversion mode, so often produce harmonics and waveform distortion in the speed, will affect the normal use of equipment, therefore, should be installed in a line choke the input end of the inverter can improve the power factor and harmonic current suppression filter, harmonic voltage and harmonic current, improve the quality of power grid.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range