• Barbed Wire/Barbed Wire Price Per Roll/Barbed Wire Roll Price Fence/Barbed Wire System 1
  • Barbed Wire/Barbed Wire Price Per Roll/Barbed Wire Roll Price Fence/Barbed Wire System 2
  • Barbed Wire/Barbed Wire Price Per Roll/Barbed Wire Roll Price Fence/Barbed Wire System 3
Barbed Wire/Barbed Wire Price Per Roll/Barbed Wire Roll Price Fence/Barbed Wire

Barbed Wire/Barbed Wire Price Per Roll/Barbed Wire Roll Price Fence/Barbed Wire

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
10 m.t.
Supply Capability:
5000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Item specifice

Material:
Galvanized Iron Wire
Cross Sectional Shape:
Round
Application:
Protectiong Mesh
Type:
barbed wire coil
Wild in Width:
1.1M
Surface Treatment:
zinc galvanized
Metal Wire Drawing:
Hot Drawing
Status:
Hard State
Thickness:
Metal Thick Wire
Galvanized Technique:
Hot Dipped Galvanized,Electro Galvanized

Product Description

TypeWire Gauge (SWG)Barb Distance (cm)Barb Length (cm)
Electric Galvanized Barbed Wire;

Hot-dip zinc plating barbed wire
10# x 12#7.5-151.5-3
12# x 12#
12# x 14#
14# x 14#
14# x 16#
16# x 16#
16# x 18#
PVC coated barbed wire;

PE barbed wire
before coatingafter coating7.5-151.5-3
1.0mm-3.5mm1.4mm-4.0mm
BWG11#-20#BWG8#-17#
SWG11#-20#SWG8#-17#

High Quality Hot DIP Galvanized Barbed Wire for Sale
Barbed wire  weave types

 A) double strand common twisted barbed wire 
 B) single strand barbed wire
 C) double strand double twisted barbed wire;

Packing 
nude packing, then loaded onto pallets; Or according to your requirements
High Quality Hot DIP Galvanized Barbed Wire for SaleApplication
1.) the protection net in industry
2.) agriculture,animal husbandy,dwelling houses
3.) plantation of fencing,grass boudary
4.) ranch and livestock farn, detention houses
5.) railways and highways 
High Quality Hot DIP Galvanized Barbed Wire for Sale
Company Profile
 
All our products are with High quality and favorable price. We're pleased to get your Inquiry and assure you our prompt response . We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective. Looking forward to serving you!
 
Production Range &Main Processed Products

CatalogRelative Products
 
 
Plastic Sheet
UHMWPE sheet            
HDPE sheet   
PVC sheet  
PP sheet     
Nylon sheet 
Single color sheet ,
Double Color sheet ,
Triple color sheet          
Plastic products :Synthetic ice rink board ,Crane outrigger pad,Temporary ground mat, Cutting board  ,Construction formwork board ,Plastic machinery parts .
 
 
Construction Hardware
Concrete Accessory: Bar Support ,Anchor Bolt ,Washer, Nails etc.
Nails: Bulk Nails ,Collated Nails, Coil roofing nails ,Stainless steel nails  etc.
Building Products: corrugated steel sheets, Concrete Floor Machine, Corrugated steel roof sheet making machine

FAQ

We have organized several common questions for our clients,may help you sincerely: 

①How about your SA Market Hot Dipped Galvanzied Barbed Wire 10kg per Roll 1kg Per Roll?

One of the most biggest manufacturer & supplier of wires and wire mesh,is a large-scale professional UAE Market Electric Galvanised Wire BWG 20 0.7mm Hot Dipped Galvnised Wire  factory in China. Annually more than 10000 tons wires and wire mesh are exported to markets all over the world. Different kinds of wires and mesh are available according to customer’s requirements. 

②What is your Technical Information oft SA Market Hot Dipped Galvanzied Barbed Wire 10kg per Roll 1kg Per Roll?

1).Material: super carbon steel

2).Processing by drawing, hot-dip zinc-plating

3).Standard wire gauge from 8# to 24#

4).Thick zinc-coating layer

5).Super in corrosion resistance

6).Firm coating layer

7).Custom size available

 10 to 15g Zinc Coating and 35kg Tensile Strength Iron Wire Electro Galvanized Iron Wire

③How long can we receive the product after payment?

In the purchase of Galvanized Iron Wire within three working days, We will arrange the factory delivery as soon as possible. The pacific time of receiving is related to the state and position of customers. Commonly 15 to 20 working days can be served。

SA Market Hot Dipped Galvanzied Barbed Wire 10kg per Roll 1kg Per Roll

 

Q:I attempted to change a bathroom fan to a new one with the help of a friend. He disconnected all the wiring without paying attention to what he was doing and what was wired where. We have a set of wires coming from somewhere (I presume the fuse box) to the fan that is hot regardless of the switch being on or off. That has a black, white and naked wire in it. Then we have another wire that comes from the switch that has black, white and naked as well. The fan has black, white and green. Can someone please tell me how to connect these as we have tried everything and the only thing that works is wired to the constant hot which of course won't allow us to turn the fan off with the switch...
You need to pull your wall switch to see how it is wired. I suspect the original wiring used the black and white on the switch itself which would make the white actually black or hot instead of neutral. If on one side of the wall switch the black wire is wired and the other the white then you need to wire the black from the fuse panel to the black going to the switch. Then the white coming from the switch to the black on the fan. The white on the fuse panel wire would be wired to the white from the fan and all grounds(bare and green) wire together.
Q:i hate the wired controllers. they all get tangled
All DualShock2s are wired. However, a company named Katana made a wireless controller called the force2 that was of high enough quality that Sony made it an officially licenced product (as opposed to all the other third-party controllers) and allowed them to use the same physical design and packaging as the actual DualShock2s. It's a nice little controller, though it doesn't like rechargeable batteries at all.
Q:I have a Hunter 5 minute fan. I have four wires coming from my ceiling. Red, Black, White, and Bare Copper. The Fan has a Green Wire, Black Wire, White WIre,and a Black/White striped Wire. The Ceiling Plate also has green wire. I know to connect the black to black, red to black/white striped, white to white. But for the green and copper wires, do I connect the copper wire from the ceiling to the green wire in the ceiling plate and also to the green wire from the fan?
This Site Might Help You. RE: Where do I connect the green ground wires on my ceiling fan? I have a Hunter 5 minute fan. I have four wires coming from my ceiling. Red, Black, White, and Bare Copper. The Fan has a Green Wire, Black Wire, White WIre,and a Black/White striped Wire. The Ceiling Plate also has green wire. I know to connect the black to black, red to black/white striped,...
Q:I want to know what the definition is of a hot wire gauge.
I would need to hear this term used in context. It could mean the gauge of the 'hot' wire which would refer to the size of the wire being used to conduct the positive ('hot') flow of electricity.
Q:I wanna know how does the temperature affect the resistance of the wire.
Cold wire is a better conductor of electricity than hot wire. Atoms are closer together when cold, making it easier for electrons to jump from atom to atom.
Q:My home is wired for the thermostats with two wires (red and white). I have acquired a new thermostat that requires a Red, White, and Common wire. Using the white wire in that position will power the unit up but it won't trigger the heat. Is there something that can be put in line that will allow this thermostat to work without rewiring the house?
T-stat wires are usually left loose in the wall, no staples, so you can easily replace it by pulling a new wire through with the old one. First try to get an idea of where the wire goes. Get an estimate of total length and go to home depot and purchase 18-3 t-stat wire. They sell it in 25 feet, 50 feet, 100 feet, 500 feet, or by the foot. Compare prices and get enough to make a continuous run. Older 2 wire Tstats used a mercury or spring switch to simply connect the two wires together (24v + and sl return). Your new Tstat needs a common because it is being powered by the same feed that activates the unit. (So you have 24+ 24- and sl return) When you attach your new wire to your old wire be sure to actually strip the outer coating of about 4 inches or so and fold the wires around each other to get a good strong bond, and then tape it tight to keep it as small diameter as possible.
Q:Replaced the old fan in my bathroom (about 10 years old) with a new fan. Trouble is this. The fan and light each work on a seperate bathroom switch. I have two spots to install the wire on the new bathroom fan/light. One for the fan and one for the ligth. However, the wiring has one white, one black, one red and the ground. Anyone know what the red is? Can I just cap it off? According the bathroom fan wiring it says something about connecting red to blue. I am slighty confused. I think it was originally only wired between the white and black. I am not sure if I have to get some extra wire and connect the black and red to the light and the white to the fan? Extra wire is confusing.
Red and black are both hot, white is neutral. Use black for fan and red for light or vice versa, depending on which switch you want to operate each one. Added - Have to hook up the white neutral wire to both the fan and the light, this creates the electrical circuit needed. You can attach all the white wires together with a wire nut.
Q:The wire from the cicuit breaker
Dryer is 220V and usually 30 amperes. Go with 10 gauge or larger (smaller number).
Q:I have a universal 02 sensor 4 wire (black, black, white and blue) the stock is white black and grey how do I wire it? thanks :)
Keep in mind the sensor has a signal wire, a ground wire and a heater wire (or wires). Good luck!
Q:Are toast - previous owner did a bad amp install on them and there is basically no wire left to use for mine.Is it possible to run a radio power wire/remote wire from the fuse panel back to the radio? If so can i just shove the wire in the fuse holder then stick the fuse back in on top of it?((Fuse 8 is the mustangs radio fuse))
Never wire anything into your fuse box, that will defeat the purpose of having it. You will have to do what's called a hard wire. You will need to run all new wires, which is the safest way to do it, with all proper fusing. A constant +12, a switched +12 and a ground is all you need for the radio to work, and all new speaker wires. If you can find one in a junkyard, you might be able to find a new harness to repair the OEM one, and that would really help you out. Good luck!

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords