ABRASIVE WHITE FUSED ALUMINA 120#-150#

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
1000MT m.t./month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specification of Abrasive White Fused Alumina

Item

Chemical Composition

Al2O3

min

NaO2

max

SiO2

max

Fe2O3

max

12#-60#

99.15

0.26

0.08

0.05

60#-100#

99.15

0.28

0.09

0.06

120#-150#

99.1

0.29

0.10

0.08

180#-220#

99.05

0.31

0.12

0.1

230#-800#

98.5

0.5

0.15

0.1

1000#-1200#

98.1

0.6%

0.18

0.1


Packaging & Shipping

In 1MT jumbo bag or as the buyer request.

We ship the cargo in 20' GP containers,each container loads 25MT/20bags.


Application of white fused alumina

Made of abrasive, suitable for grinding hardened alloy steel, high speed steel. Fine-grained flour is also used for precision casting.



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What do refractory materials include?
It is so difficult.
Q:what's the standard of fireproofing material?
Class A1 is divided according to the combustion performance of GB8624-2006 building materials and products. Specific technical index requirements are: 1, the temperature rise ≤30 degrees;mass loss rate ≤50%; combustion duration time is 0; 2, main components, overall products, gross calorific value of external secondary components ≤2.0MJ/kg; any inner secondary component ≤1.4MJ/kg; (there are difference between homogeneous and non-homogeneous). Z802 building materials noninflammability testing furnace has to be used for testing technical indicators mentioned in test 1, using Z805 building materials combustion heat value to test technical indicators mentioned in test device 2.
Q:What are the fire protection standards of insulation materials?
This question is, like this. The combustion performance of thermal insulation materials for exterior walls of all civil buildings, within the scope of fire design auditing and fire control acceptance, should be brought into the auditing and acceptance. As for the "Management Regulations on Supervisions of Fire Prevention and Control for Building Projects" (Ministry of Public Order No. 106) , all civil buildings which are out of the scope of Article 13 and 14 are included in the random check. Before the release of new standard, it must be strictly implemented the Article II of the "Fire prevention Interim Provisions on civil external wall insulation system and external wall decorative" ([2009] No. 46), namely, the insulation materials of civil buildings must use materials with A-level combustion performance.
Q:How to determine the fire resistance rating of the aluminium-plastic panel?
Fire rating of the best aluminium-plastic panel in the current market is B1 class, and its grade classifications can refer to the national standard. I have examined factories and tested the fireproof effect of the fire-proof plate myself by burning it, and I have found that the fire-proof plate of Jinwei Aluminium-plastic Panel in Linyi is really good in quality and fire prevention. In other words, from the single point of fire rating, the corresponding fire rating of the called fireproof aluminum (plastic) composite panel should be at least B class, and for A2 class fireproof aluminum composite panel, its core material currently doesn't include plastic element, so it's called aluminum composite panel which is of inorganic core material. If the ordinary aluminum-plastic panel is classified according to the fire-proof building material, it will belong to that of lower level. For aluminum-pastic panel used in business premises, it is required to reach the grade of flame retardant material or above this in fire prevention. It is expressly stipulated that its fire rating should be A2 class in public places.
Q:Can quantitative feeder be used in refractory plant? Thank you
Well, can the Weifang Sanyou automation equipment production chain plate feeder is fully applicable to the measurement and control of boring high temperature, chain plate feeder with 16 4-5MM manganese plate.
Q:How to classify fire resistance rating of brick-concrete structure?
In order to ensure the safety of the building, the fire protection measures must be taken to make it have a certain degree of fire resistance, even if there is a fire, it will not cause too much damage. According to the national conditions of our country, and in the light of other countries standards, < high-rise civil building fire protection design specification > defines fireproof rank of high-rise civil buildings into level one and two; < code for fire protection design of buildings > divides the rank into level one, two, three, four, level one is the highest level, level four is the lowest. Besides that the minimum fire resistance of the building component is specified, buildings of fire resistance rating also specified requirements for combustion performance. Because the component with the same fire resistance limit is different, it is different in the fire.According to our country national standard < building design fire protection code >, the fire resistance rating of the building is divided into four levels. The fire resistance of a building is determined by the combustion performance and fire resistance of building components (such as beams, columns, floors, walls, etc.). Generally speaking, the fire resistance building of level one is a mixed structure of reinforced concrete structure or a mixture of brick wall and steel concrete structure; the fire resistance building of level two is a mixed structure of steel truss structure, reinforced concrete column and brick wall; the fire resistance building of level three is brick-wood structure made of wood roof and brick wall; the fire resistance building of level four is combustible structure which is composed of wood roof and non-combustible wall.
Q:What refractories are resistant to fluorine gas?
It is recommended to use fused-quartz brick, which will produce hydrofluoric acid fluorine (an acidic gas) when water vapors. It is cheap. While it is recommended to use silica brick if it exceeds 1,200 degrees. So acidic refractory is an advisable refractory for using. It works well if the temperature is below 1200 degrees.
Q:how to divided the external wall thermal insulation materials fire rating
Level A: Incombustible building material is a material that does not occur any burning. Level A1: Noncombustible means no open fire. Level A2 It is noncombustible, and should measure smoke to be qualified. Level B1: Nonflammable building material: Non-flame material has good flame resistance. It is difficult to fire under the condition of open fire in the air or high temperature, and it is not easy to quickly spread, and when the combustion source is removed, the combustion will stop immediately. Level B2: Combustible building materials: Flame material has a good flame resistance. In case of fire in the air or at high temperature, it will immediately burst into flames, and easily lead to the spread of fire, such as wooden column, timber roof truss, timber beam and wooden stairs. Level B3: inflammable building material has no any flame resisting effects, and is easy to burn, so the fire risk is high.
Q:Does the external wall thermal insulation materials level b1 need the fire barrier zone?
First, it is prohibited that the thermal insulation material of level B2 and below combustion performance is used in the thermal insulation project of any civil building wall, and the thermal insulation material of below level A combustion performance is used in the thermal insulation project of curtain wall civil builduing that the height is equal and greater than 24m, of non-curtain wall residential building that the height is equal and greater than 100m and of other non-curtain wall civil builduing that the height is is equal and greater than 50m. Civil builduing wall thermal insulation project must strictly enforce the "civil builduing external wall thermal insulation systems and external wall decoration fireproofing interim provisions" (referred to as "fireproofing interim provisions").
Q:What is shapeless refractory with high performance?
The popular ones are: Non-cement fine powder bonded castable is a functional refractory castable with nano material introduced.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range